Please refer to the M5600_U5600 Installation Manual and M5600_U5600 Software Manual.
Note:
Communication is max 65 feet
TE CONNECTIVITY SENSORS
/// M5600
09/2017
Page 3
M5600
Wireless Pressure Transducer
ORDERING INFORMATION
M5600
–
0 0 0 0 0 2
–
05KP G
Port Material
0
17-4PH
1
316L Stainless Steel
Cleaning
0
No Selection
1
Oxygen clean B40.1 Level IV
2
With Snubber
Battery
0
Without Battery
1
CR2032
2
CR2050
Label Type
0
Adhesive Label
1
Laser Marking
Pressure Port
2
1/4-19 BSPP
3
G3/8 JIS B2351
7/16-20UNF Male SAE J1326-2
4
Straight Thread O-Ring BUNA-N
90SH-904
5
1/4-18 NPT
6
1/8-27 NPT
B
G1/4 JIS B2351
E
1/4-19 BSPT
F
1/4-19 BSPP Female w/o Snubber
7/16-20 UNF Female SAE J513
P
Straight Thread
7/16-20 UNF Female SAE J513
N
Straight Thread
M10x1.0mm
Q
ISO 6149-2
M12x1.5mm
S
ISO 6149-2
G1/4 DIN 3852 Form E Gasket
U
DIN3869-14 NBR
M20x1.5mm
W
ISO6149-2
M14x1.5mm
G
ISO6149-2
Pressure Type
G
Gauge
S
Sealed
C
Compound
Compound pressure range is -14.7 to xxxpsig or -1 to xxxbarg.
(e.g. 200PC: -14.7 to 200psig, 020BC: -1 to 20barg)
Pressure Range [psi]
psi
STD
050P
100P
200P
300P
500P
01KP
03KP
05KP
07KP
10KP
15KP
bar
STD
3.5B
007B
010B
020B
035B
070B
200B
350B
500B
700B
01KB
NORTH AMERICA
Measurement Specialties, Inc.,
a TE Connectivity Company
Phone: 800-522-6752
Email:
customercare.frmt@te.com
EUROPE
Measurement Specialties (Europe), Ltd.,
a TE Connectivity Company
Phone: +31 73 624 6999
Email:
customercare.lcsb@te.com
ASIA
Measurement Specialties (China), Ltd.,
a TE Connectivity Company
Phone: 0400-820-6015
Email:
customercare.shzn@te.com
TE.com/sensorsolutions
Measurement Specialties, Inc., a TE Connectivity company.
Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein
might be trademarks of their respective owners.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes
no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard
Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse
of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
1 Introduction
In recent years, there have been many major advances in the production technology and processes of automotive headlights, which have greatly improved the performance of automoti...[Details]
Different initialization between C8051F and 80C51 series microcontrollers
In the past 30 years, major electronic component manufacturers in the world have launched their own unique single-chip...[Details]
Motors are important products that convert electrical energy into mechanical energy to achieve automation, and they are widely used in industrial control, medical electronics, white a...[Details]
Today, with energy becoming increasingly scarce, the utilization of natural energy has become the focus of people's attention. Among various natural energies, the endless solar energy is highly fav...[Details]
Currently, each country is developing its own USB interface
charging specifications
, which leads to a major problem that a USB interface
charging
device manufactured in one country...[Details]
Traditional
virtual instruments
consist of a data acquisition
board
based on PCI bus and
corresponding software. However, with
the rapid development of
computer
network techno...[Details]
Every time I go home and walk up the stairs, I am always scared. The corridor lights are often broken, and no one changes the bulbs, or they are not smart enough and need to be operated manually. E...[Details]
Almost everyone in a student dormitory has a bedside lamp. But if you want to read for a while after turning off the lights and don't want to disturb your roommates' sleep, you may need a reading l...[Details]
The fluorescent lamps and energy-saving lamps we commonly use now have greatly improved luminous efficiency compared with the earlier ordinary incandescent lamps and have been widely used. With the...[Details]
Today, with the increasing integration of functions, mobile phones can also be used as portable media players (PMP), digital cameras, handheld computers (PDAs), and even global positioning systems (GP...[Details]
The capacity of a battery depends on the amount of charge and discharge, in addition to some factors of the battery itself. Obviously, if the charge and discharge of the battery can be recorded all...[Details]
1 Introduction
Automatic Test
System The ATS (Automatic Test System) integrates all the stimulus and measurement equipment required for testing.
The computer
efficiently comp...[Details]
0 Introduction
In the design and construction of communication systems,
communication power supply
is called the heart of the communication system. The power supply system will dire...[Details]
The biggest advantage of Profibus is that it is guaranteed by the stable international standard EN50170 and has been proven to be universal in practical applications. It has been widely used in man...[Details]