Part Number

Search

U539P-020002-100PC

Description
Peizoresistive Sensor, Compound, -14.7Psi Min, 100Psi Max, 0.1%, 0.5-4.5V, Cylindrical
CategoryThe sensor   
File Size319KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

U539P-020002-100PC Overview

Peizoresistive Sensor, Compound, -14.7Psi Min, 100Psi Max, 0.1%, 0.5-4.5V, Cylindrical

U539P-020002-100PC Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTE Connectivity
Reach Compliance Codeunknow
Maximum accuracy(%)0.1%
Other featuresPort Height = 13.9 MM
body height64.9 mm
Body length or diameter24 mm
Maximum working current5 mA
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0.5-4.5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port type1/4-19 BSPP
Maximum pressure range100 Psi
Minimum pressure range-14.7 Psi
Pressure sensing modeCOMPOUND
Sensor/temperature sensor typePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage30 V
Minimum supply voltage5 V
Termination typeCABLE
U5300
Industrial Pressure Transducer
SPECIFICATIONS
Superior Accuracy and Total Error Band
Instrument Grade and Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Absolute, Compound
Expedite Configurations Available (10 Days)
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.1% Accuracy
±0.5% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The instrument grade U5300
pressure transducers from the UltraStable line
of MEAS, with their modular design, offer maximum flexibility for different
configurations. This latest series features superior accuracy and total error
band for demanding commercial and heavy industrial applications. This
series is suitable for measurement of liquid or gas pressure, even for difficult
media such as contaminated water, steam, and mildly corrosive fluids.
The wetted material is made of 316L stainless steel and the transducer’s
durability is excellent with no O-rings or organics exposed to the pressure
media. The U5300 is weatherproof and exceeds the latest heavy industrial
CE requirements including surge protection. The circuit is protected from
reverse wiring at input and short circuit at output.
This product is geared to the OEM customer for low to mid volumes. MEAS
stands ready to provide a custom design of the U5300 where the volume and
application warrants. Additional configurations not listed are either available
or possible. Please inquire for further information.
APPLICATIONS
Military/Aerospace Test Stands
Automotive Test Stands
Calibration Equipment
High Accuracy Applications
Stationary Motor Fuel Control
High End Industrial Machinery
SENSOR SOLUTIONS
///U5300
07/2018
Page 1
Who will fill the “gap” in China’s auto parts market?
In Hall W6, the presence of numerous foreigners confirmed the approach of these exhibitors. -------"Our electronic products are sold abroad, not for the domestic market. Why is that? Everyone seems to...
babbage Automotive Electronics
GPIO Interrupts
My platform is pxa255 + wce4.2. When adding a custom interrupt, the first thing is to connect the hardware, that is, the interrupt source is connected to a GPIO of pxa255, and the GPIO is set to input...
luoyaxu Embedded System
How to get the number of physical hard disks?
I checked MSDN and found CLUSCTL_RESOURCE_TYPE_STORAGE_GET_AVAILABLE_DISKS, but it is too annoying to use. Is there a function like _getdrives that can do it with one sentence?...
zhanying012 Embedded System
Finally bought a refurbished XPS laptop
[font=微软雅黑][size=3]I just bought a new computer. It was supposed to be unboxed, but unfortunately I bought an official refurbished version. Without the original box and film, there is nothing to unbox...
eric_wang Talking
TCPMP interface problem
The bitmap drawn in the static LRESULT CALLBACK Proc(HWND Wnd, UINT Msg, WPARAM wParam, LPARAM lParam) function of TCPMP is always covered by other windows. Does anyone know why? Thanks! case WM_PAINT...
chenxb19831118 Embedded System
Regarding the removal of a lot of noise when displaying images on LCD12864...
When LCD12864 displays images, there are many noises around them. What good suggestions do experts have for removing the noises? I have tried delaying the start of the program and clearing the screen,...
gh131413 Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1146  663  1727  1763  2052  24  14  35  36  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号