The ASDX Series is a Silicon Pressure Sensor offering a
ratiometric analog output for reading pressure over the
specified full scale pressure span and temperature range.
The ASDX is fully calibrated and temperature compensated for
sensor offset, sensitivity, temperature effects and non-linearity
using an on-board Application Specific Integrated Circuit
(ASIC). Calibrated output values for pressure are updated at
approximately 1 kHz.
The standard ASDX is calibrated over the temperature range
of 0 °C to 85 °C [32 °F to 185 °F]. The sensor is characterized
for operation from a single power supply of either 3.3 Vdc or
5.0 Vdc.
FEATURES
•
•
Ratiometric 12-bit analog output
Precision ASIC conditioning and temperature
compensated over 0 °C to 85 °C [32 °F to 185 °F]
temperature range
•
•
•
•
•
•
Low operating voltage
Absolute, differential and gage types
Pressure ranges from 10 inches H
2
0 to 100 psi
Standard calibrations in inches H
2
0, cm H
2
0, psi, mbar,
bar, kPa
Total error band of ±2.0% of full scale span maximum
RoHS compliant
•
•
•
•
•
•
•
These sensors are available to measure absolute, differential
and gage pressures. The absolute versions have an internal
vacuum reference and an output value proportional to absolute
pressure. Differential versions allow application of pressure to
either side of the sensing diaphragm. Gage versions are
referenced to atmospheric pressure and provide an output
proportional to pressure variations from atmosphere.
The ASDX Series sensors are intended for use with non-
corrosive, non-ionic working fluids such as air and dry gases.
They are designed and manufactured according to standards
in ISO 9001.
POTENTIAL APPLICATIONS
Flow calibrators
Ventilation and air flow monitors
Gas flow instrumentation
Sleep apnea monitoring and therapy equipment
Barometry
Pneumatic controls
HVAC
ASDX Series Silicon Pressure Sensors
Table 1. Absolute Maximum Ratings
Parameter
Supply voltage (V
supply
)
Voltage to any pin
ESD susceptibility (human body model)
Storage temperature
Lead temperature (2 s to 4 s)
2
External capacitance between V
supply
and ground
Table 2. Operating Specifications
Parameter
3
Supply voltage (V
supply
)
3.3 Vdc
5.0 Vdc
Sensors are either 3.3.Vdc or 5.0.Vdc based on models chosen per the
order guide (see Figure 1).
1
Min.
-0.3
-0.3
3
-50 [-58]
-
100
Max.
6.0
V
supply
+ 0.3
-
125 [257]
250 [482]
470
Unit
Vdc
Vdc
kV
°C [°F]
°C [°F]
nF
Min.
3.0
4.75
1.5
0 [32]
-20 [-4]
Typ.
3.3
4
5.0
4
Max.
3.6
5.25
Unit
Vdc
mA
°C [°F]
°C [°F]
Supply current
5
Compensated temperature range
6
Operating temperature range
7
Overpressure
8
Burst pressure
Startup time (power up to data ready)
Response time
Upper output clipping limit
Lower output clipping limit
Minimum load resistance
9
Total error band
Output resolution
Table 3. Environmental Specifications
Parameter
Humidity
Vibration
Shock
Life
Table 4. Wetted Materials
Parameter
Covers
Adhesives
Electronic components
11
-
-
97.5
-
5.0
-
12
2.5
3.5
-
85 [185]
-
105 [221]
2X operating pressure range minimum
3X operating pressure range minimum
-
5
1.0
-
-
-
-
2.5
-
-
-
2.0
-
-
ms
ms
% V
supply
% V
supply
kOhm
10
%FSS
bits
Characteristic
0% to 95% RH non-condensing
10 G at 20 Hz to 2000 Hz
100 G for 11 ms
1 million cycles minimum
Port 1 (Pressure Port)
glass-filled PBT
silicone
silicon and glass
12
Port 2 (Reference Port)
glass-filled PBT
silicone and epoxy
silicon, glass, and gold
12
Notes:
1.
Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device.
2.
An external bypass capacitor is
required
across the supply voltage (Pins 1 and 3 – see Figure 4) as close to the sensor supply pin as possible for correct sensor
operation.
3.
Ratiometricity of the sensor (the ability of the output to scale to the input voltage) is achieved within the specified operating voltage for each option. Other custom
supply voltages are available, please contact Honeywell Customer Service.
4.
The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin may cause electrical failure.
5.
The compensated temperature range is the temperature range (or ranges) over which the sensor will produce an output proportional to pressure within the
specified performance limits.
6.
The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not remain within the
specified performance limits.
7.
Overpressure is the maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating
pressure range. Exposure to higher pressures may cause permanent damage to the product.
8.
Burst pressure is the maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product should not be expected
to function after exposure to any pressure beyond the burst pressure.
9.
Total error band is the maximum deviation in output from ideal transfer function over the entire compensated temperature and pressure range. Includes all errors
due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span and thermal hysteresis.
Specification units are in percent of full scale span (%FSS).
10. Full scale span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range.
11. Consult Honeywell Customer Service for detailed material information.
12. For the AC pressure port configuration, the “pressure” and “reference” ports are reversed.
2
www.honeywell.com/sensing
Low Pressure and Ultra-Low Pressure Analog Output
Figure 1. Nomenclature and Order Guide
Notes:
13. Other package combinations are possible, please contact Honeywell Customer Service.
14. The transfer function limits define the output of the sensor at a given pressure input. By specifying the output signal at the maximum (Pmax.)
and minimum (Pmin.) limits of the pressure range, the complete transfer curve for the sensor is defined. See Figure 2 for a graphical
representation of each calibration.
15. For a digital output, please refer to the ASDX Digital Series.
The PRIGROUP field in the APINT register can set the preemption priority and sub-priority levels. Refer to the statement on P114 of the CM3 authoritative guide: If only 3 bits are used to express the ...
I am currently writing a series of articles on the ardupilot transplantation, which was completed in 2019.Hardware Platform: TM4C1294XL LaunchPad
The software platform is RT-Thread operating system
Po...
The market demand for Class D audio power amplifiers is growing at a rate of about 50% per year, with high-performance devices as the target application. The high energy efficiency and low heat dissip...
I want to ask for a stable RF IC. This is my first time to do RF. I want to make a wireless remote control bicycle alarm. If the bicycle is placed outside the door, it can alarm if the bicycle moves....
I am a junior college student majoring in embedded systems. This is my first time to use STM32. The teacher gave us a topic: a data sampling system based on STM32. I would like to ask you how to solve...
introduction
Oxygen is an important substance for human metabolism. Brain tissue has a high metabolic rate and consumes about 20% of the total oxygen in the body. In the clinical rescue and ...[Details]
With the continuous improvement of living standards and the increase in the proportion of urban aging, the household use of medical electronic equipment has gradually become a trend. Among them, the...[Details]
A biped robot joint constructed by pneumatic artificial muscles is introduced. The joint uses the flexible characteristics of pneumatic artificial muscles to effectively control the impact of the la...[Details]
At present, the global medical electronics industry is gradually showing attractive development prospects, and the speed of product replacement is constantly increasing. At the same time, due to the p...[Details]
As a branch of signal and information processing, digital signal processing has penetrated into various fields of scientific research, technological development, industrial production, national defens...[Details]
At present, a hot spot for the research and development of hearing aids abroad is concentrated in China. To be more precise, it is based on the research of Chinese language and speech, and the deve...[Details]
In some warehousing management, manufacturing, meteorological observation, scientific research and daily life, the requirements for temperature and humidity are common. For example, the "Interim Pr...[Details]
This issue will briefly introduce the test related to spectrum - occupied bandwidth.
Definition: Occupied bandwidth refers to the bandwidth corresponding to 99% of the total transmitted power, cent...[Details]
0 Introduction
Today, with the rapid development of electronic technology and the emergence of new multifunctional electric energy meters, the choice of memory in the electric energy m...[Details]
Overview
Currently, many portable consumer electronic products, such as mobile phones, PDAs, MP3 players, and notebooks, are equipped with display screens. Although the type and size of the di...[Details]
When using GPS for positioning, it will be affected by various factors. The factors that affect the accuracy of GPS positioning can be divided into the following four categories (see the figure be...[Details]
MOSFETs are widely used as power switching elements in regulators and motor controllers. They are available as discrete devices or integrated into ICs in various H-bridge configurations.
A hig...[Details]
In order to ensure the reliability of the driving assistance system and the basic functions of the car, and also to leave suitable connection interfaces for the car's future new entertainment and ...[Details]
Preface
In recent years, many compact portable electronic products have been developed, such as mobile phones, digital cameras, MP3, MP4, PDA, GPS and DVD, etc. They are not only small in size...[Details]
1 Introduction
Reliability research originated from weapon systems. After nearly half a century of development, it has become an engineering discipline that covers all disciplines and industri...[Details]