EEWORLDEEWORLDEEWORLD

Part Number

Search

TCL450DL3-ACF2

Description
TIME DELAY BLOW ELECTRIC FUSE, 100A, 125VDC, INLINE/HOLDER
CategoryCircuit protection   
File Size106KB,2 Pages
ManufacturerETC
Download Datasheet View All

TCL450DL3-ACF2 Overview

TIME DELAY BLOW ELECTRIC FUSE, 100A, 125VDC, INLINE/HOLDER

TYPE:
CATALOG NO.:
General Description
The CCL/TCL Series provides functional emer-
gency lighting in a variety of wattages up to 450
watts. High performance electronics and rugged
18 gauge steel construction ensure long-term life
safety reliability.
CCL/TCL Series
Housing
High Capacity Steel Emergency Lighting Units
6 and 12 Volt, 75 to 450 Watts
Wet Cell Lead Calcium Battery
Constructed of 18 gauge steel with a tan epoxy powder
coat finish.
Knockouts provided for mounting up to three lamp
heads.
Bi-color LED charge monitor/indicator and a “press-to
test” switch are located on the front of the cabinet.
Choice of wedge base, sealed beam tungsten, or halogen
lamp heads
Illumination
Illumination is accomplished with up to three
lamp heads mounted on the top of the unit. The
most popular lamp head for use with the CCL/TCL
Series is the “D” Series round sealed beam Par 36
tungsten lamp head. The “D” head is available up
to 30 watts.
Dimensions
CCL75, CCL100, CCL150, CCL225,
TCL150, TCL200
6.0”
(15.2 cm)
Electronics
120/277 VAC dual voltage input with surge-protected,
solid-state circuitry provides for a reliable charging
system.
Charging system is complete with low voltage
disconnect, AC lockout, brownout protection,
AC indicator lamp and test switch.
Includes two fused output circuits.
7.6”
(19.3 cm)
Shown: CCL150DL2
Battery
Low maintenance, free electrolyte, wet cell, lead
calcium battery
Specific gravity disk indicators show relative state
charge at a glance
Operating temperature range of battery is 65°F
(19°C)
to 85°F
(30°C)
12.0”
(30.5 cm)
16.0”
(40.6 cm)
TCL300, TCL450
6.0”
(15.2 cm)
12.0”
(30.5 cm)
Utilizes a fully automatic voltage regulated two-rate cur- Battery supplies 90 minutes of emergency power
rent limited solid-state charger -- initially provides a high
rate charge upon restoration of AC power, and provides
Code Compliance
trickle charge to maintain batteries at full capacity once UL 924 listed
float voltage is attained.
NFPA 101
Optional ACCU-TEST Self Diagnostics includes an auto-
NEC BOCA and OSHA illumination standard
matic 3 minute discharge test every 30 days. A manual
test is available from 1 to 90 minutes.
Performance
Warranty
27.0”
(12.7 cm)
Three year full electronics warranty
7.6”
(19.3 cm)
Input power requirements
120 VAC - 0.66 amps, 80 watts
277 VAC - 0.30 amps, 80 watts
One year full plus four year prorated battery warranty
Ordering Information
CCL
SERIES
CCL = 6 Volt
TCL = 12 Volt
150
DC
WATTAGE
6 Volt
75 = 75 Watts
100 = 100 Watts
150 = 150 Watts
225 = 225 Watts
12 Volt
(Includes standard voltmeter)
150 = 150 Watt
200 = 200 Watt
300 = 300 Watt
450 = 450 Watt
DL
LAMP
HEADS
6 Volt
DY = 8 Watt, Tungsten
DA = 18 Watt, Tungsten
DL = 25 Watt, Tungsten
DC = 30 Watt, Tungsten
12 Volt
DNY = 12 Watt, Tungsten
DE = 28 Watt, Tungsten
DK = 25 Watt, Tungsten
DG = 30 Watt, Tungsten
(Suggested lamp heads listed
above. Refer to the Accessories Section for
additional lamp head choices.)
2
# OF
HEADS
3 = Three
2 = Two
1 = One
TD1
FACTORY INSTALLED
OPTIONS
1
ACCESSORIES
A = Ammeter
2
ACF1 = 120 VAC Fuse
LMSHELF = Mounting Shelf 300-450W
ACF2 = 277 VAC Fuse
MXSHELF = Mounting Shelf 72-200W
ACP1 = 120 VAC Power Switch
ACP2 = 277 VAC Power Switch
AD = ACCU-TEST Self-Diagnostics
ADAL = ACCU-TEST with Alarm
ADTD = ACCU-TEST with Time Delay
3
DCP = DC Power Switch
EX = Special Input Transformer
(Specify voltage and frequency)
TD1 = 120 VAC Time Delay
3
TTD2 = 277 VAC Time Delay
3
V = Voltmeter
2
W = White Housing
Notes:
1) Some option combinations may impact UL list-
ing. consult factory for specifics.
2) Not available witj AD, ADAL, or ADTD options.
3) 15 minute delay.
C1063
R4
9/02 IH
25 poems that will make you laugh
1. I wish to be a pair of wings in the sky, and fly away separately when disaster strikes. (You two are really a perfect match) 2. I urge you to drink another cup of wine, and from now on Xiao Lang is...
huipeng001 Talking
About wince5.0 automatic upgrade program
I would like to ask if any experts have done an automatic update program under wince. Can you tell me the method? Thank you in advance!...
ykfall Embedded System
[NXP Rapid IoT Review] Rapid IoT Studio online IDE User Experience
I have received the SLN-RPK-NODE kit for a few days. I have never successfully logged into the official APP. The problem of APP is easy to solve. At worst, I can write one myself. The routine program ...
littleshrimp RF/Wirelessly
PIC microcontroller programming problem
When burning the program, the message "You are trying to program over code protected areas of the device. To do this you must select segment programming on the Secure Segment property page and indicat...
cpf彩虹 Microchip MCU
EEWORLD University Hall -- Disassembly of 3 Economical Digital Multimeters
Disassembly of 3 economical digital multimeters : https://training.eeworld.com.cn/course/5230Disassembly of 3 economical digital multimeters...
soso Integrated technical exchanges
MSP430 FAQ Summary
I don't know if anyone has posted this :time:...
5xue Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2797  628  2072  2284  2459  57  13  42  46  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号