LCS051S26PD24BY

Description
SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 5.6mm, THROUGH HOLE-STRAIGHT, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size229KB,4 Pages
ManufacturerC&K
Environmental Compliance  
Download Datasheet Parametric View All

LCS051S26PD24BY Overview

SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 5.6mm, THROUGH HOLE-STRAIGHT, ROHS COMPLIANT

LCS051S26PD24BY Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerC&K
package instructionROHS COMPLIANT
Reach Compliance Codecompli
ECCN codeEAR99
Actuator stroke5.6 mm
Actuator typeSIMULATED LEVER
body width6.4 mm
body height9.8 mm
Body length or diameter19.8 mm
Contact (AC) maximum rated R load6A@250VAC
Maximum contact current (AC)6 A
Maximum contact voltage (AC)250 V
Electrical life10000 Cycle(s)
Manufacturer's serial numberLCS
Installation featuresTHROUGH HOLE-STRAIGHT
Maximum operating force1.47 N
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Maximum pre-travel4.6 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeSOLDER
LCS Series
Subminiature Sealed Snap-acting Switches
Features/Benefits
Compact design
Long life and high electrical capacity
Quick connect, solder terminals,
PC terminals, wire leads
Wide variety of actuator styles
RoHS compatible, RoHS compliant
IP67
Specifications
CONTACT RATING: 6 AMP, 125/250 V AC
and
5 AMP, 125/250 V AC
0.1 AMP, 125/250 V AC
ELECTRICAL LIFE: 10,000 cycles
INSULATION RESISTANCE: 100 M ohm min.
DIELECTRIC STRENGTH: 1,000 VAC
OPERATING TEMPERATURE: –40ºC to +125ºC without wire
–40ºC to +85ºC with wires
OPERATING FORCE: (see ACTUATOR’S option sections).
MOUNTING: 2-56 screws, torque 2.3 in/lbs max.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service center.
14
Typical Applications
Motorized equipment
Sump pump
Thermostatic controls
Computers
Air conditioners
14
Models Available
Materials
SWITCH HOUSING: Thermoplastic polyester or high temperature
thermoplastic (PTS) (UL 94V-0).
ACTUATOR BUTTON: Thermoplastic polyester.
SPRING: Copper alloy.
PIVOT: Copper alloy.
MOVABLE CONTACTS: Silver nickel
STATIONARY CONTACTS: Silver nickel on copper alloy.
TERMINALS: Copper alloy.
ACTUATOR LEVEL: Stainless steel.
J
Snap-acting
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages J-27 thru J-29. For additional options not shown in catalog, consult Customer Service Center.
L
Series
LCS
Contact Rating
05
5 AMP, 125/250 V AC
6 AMP, 125/250 V AC
01
0.1 AMP, 125/250 V AC
C
S
14
Operating Force
1
150 grams
2
203 grams
Actuator
P00
Pin plunger
T00
0.45 mm short lever
T05
5.05 mm short lever
T07
7.05 mm short lever
T13
13.15 mm lever
T19
20.95 mm lever
T28
28.35 mm lever
T43
43.55 mm lever
S26
6.25 mm simulated lever
A05
4.85 mm lever roller
Circuitry
C
SPDT
W
SPST N.C.
Y
SPST N.O.
Wire Type AWG
20
20 AWG
22
22 AWG
24
24 AWG
26
26 AWG
28
28 AWG
30
30 AWG
Wire UL #
(when required)
A
UL1007
B
UL1015
C
UL1430
D
UL1061
E
UL1330
Terminations
S
Solder
Q
0.110 Quick Connect
P
PC Thru Hole
W
Wire leads potted
Z
Wire leads non-potted
Wire Side (when required)
A
Wire out the bottom
B
Wire out the right side
C
Wire out the left side
D
None
Dimensions are shown: mm
Specifications and dimensions subject to change
J–26
www.ck-components.com
Question about BootLoader memory mapping
I have a question: In the Bootloader of 2410EBoot, why are functions like OEMDebugInit() using virtual addresses when accessing registers? For example: #define UART0_BASE 0xB1000000 // 0x50000000 When...
testlinlin Embedded System
Why can't CreateFile open my driver?
In the application: hFile = CreateFile(TEXT("KEY1:"), GENERIC_READ | GENERIC_WRITE, 0, NULL, OPEN_EXISTING, 0, 0); In the driver: DWORD KEY_Open(DWORD dwData, DWORD dwAccess, DWORD dwShareMode) { if (...
heqin509 Embedded System
【Help】ccs5 new project
[size=14.44444465637207px]Hi everyone, there are bulid-include option and linker-file search path in ccs5, both of which are used to add paths. But what files are added respectively? Also, if I use 28...
jonny0811 DSP and ARM Processors
[National Technology Low Power Series N32L43x Review] 1. Development Board Unboxing
[i=s]This post was last edited by emmnn on 2022-7-4 21:35[/i]PrefaceI happened to go home two days ago, and I didn't get the board back from the courier station until today to prepare for the evaluati...
emmnn Domestic Chip Exchange
How to start multiple programs in an embedded device simultaneously when connected to a HyperTerminal?
I use a HyperTerminal to connect to an embedded device. I can start a program through the command line in the HyperTerminal environment. But I need to execute two different programs in the device at t...
xiaozhou Embedded System
Let me share with you my key debounce program (VHDL)
There are many on the Internet. This is one I wrote a while ago: --filename : main part of digital clock system--designed by : TangQF--inputsoutputs introduction:--clk_key_deal : clk_key_deal input--r...
Sea_eeworld FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 649  2220  599  1954  198  14  45  13  40  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号