L22-B2-42-410-26A-CG

Description
Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size2MB,8 Pages
ManufacturerCarling Technologies
Environmental Compliance
Download Datasheet Parametric View All

L22-B2-42-410-26A-CG Overview

Magnetic Circuit Breaker,

L22-B2-42-410-26A-CG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerCarling Technologies
Reach Compliance Codecompli
Circuit protection typeMAGNETIC CIRCUIT BREAKER
L-Series
Circuit Breaker
Available with Current Transformer
The L-Series high performance, compact hydraulic-
magnetic circuit breaker is ideally suited for the rigors and
confined spaces found in today’s telecom/datacom power
distribution units and rack systems. It provides best in class
performance in an innovative low profile, space saving
package complementing the overall spatial objectives
required by telecommunications and data-communications
systems designers in their quest to reduce the overall size
of equipment, while increasing transmission capacity.
The optional current transformer allows outlet metering
and monitoring of power usage thus facilitating load
adjustments and maximizing efficiency.
Further, a patent
pending flush rocker actuator design and optional push-to-
reset guard offers additional protection against accidental
switching.
Number of poles: 1-3. Maximum current and voltage
ratings: .2-32A, 120/240-240VAC. Maximum interrupting
capacity: 5000 Amps
Applications:
Š
Telecom/Datacom Industry
– Power Distribution Units
– Data Servers
– Data Storage
Product Highlights:
Š
Optional current transformer
Š
Ultra low profile design saves valuable space
Š
Optional handle guard actuator
Š
UL 489 LISTED Branch Circuit breaker
Š
Designed for worldwide datacenter
compatibility with up to 240VAC ratings
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
About the error after setting STACK when compiling ATMEGA128A with IAR FOR AVR
Have you ever encountered this problem? When using IAR FOR AVR to compile ATMEGA128A program, STACK must be set to 0 to pass the compilation, otherwise an error will be reported. Why is this? ? ? Ther...
hexon Microchip MCU
MSP430F5529
I use MSP430F5529 to make an ultrasonic distance measurement module, and use 1602 display, but the measured data is 0cm. I have checked it for several days, but I don't know where the problem is. Plea...
好可爱的小多C Microcontroller MCU
What do I need to learn to develop hardware?
Want to learn, but don't know where to start?...
ljz1023 Embedded System
Recent programs. GPS reception display
Timer and serial port DMA are used. The program should be written in a standard way.The focus is on solving the problem that the serial port DMA mode reception cannot continuously receive data of diff...
astwyg stm32/stm8
(Serial 08) Working Principle of Parallel Switching Power Supply
[p=null, 2, left][color=rgb(62, 62, 62)][font="][size=16px][b]1-4-1. Working principle of parallel switching power supply[/b][/size][/font][/color][/p][p=null, 2, left][color=rgb(62, 62, 62)][font="][...
木犯001号 Power technology
[Help] A very basic circuit question! I can't do it
This question is from "Circuit" published by Higher Education Press, page 390, question 16-4.As shown in the figure, when I use the loop current method to calculate Y11 (that is, when calculating U1/I...
itmssliyan Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1678  1037  1503  999  1691  34  21  31  35  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号