Part Number

Search

LDC-100-2740x

Description
100W Output Power
File Size1MB,4 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet Compare View All

LDC-100-2740x Overview

100W Output Power

LDC-100
Series
Compact, LED, 100W
Constant Current
AC/DC Power Supply
Key Features:
100W Output Power
UL 8750 Approved
Constant Current Output
Active PFC
90 - 305 VAC Input
IP65 / IP67 Rated
Meets EN 55015, EN 61547
Dimming Function
>50 kHour Life Expectancy
Lightning Surge Protection
Over Volt/Temp Protection
Total Harmonic Distortion (THD)
Turn On Delay, See Note 3
Leakage Current
Power Factor Correction
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Inrush Current, See Note 1
Input Current
Conditions
Min.
90
127
47
230 VAC
115 VAC
230 VAC
264 VAC
0.98 @ 115 VAC
0.95 @ 230 VAC
0.93 @ 264 VAC
See Note 2
115 VAC
230 VAC
277 VAC
Conditions
V
IN
= Min to Max
See Note 4
Min.
Typ.
Max.
305
431
63
Units
VAC
VDC
Hz
A Pk
A
75
1.60
0.80
0.70
10
1.5
0.5
0.75
Typ.
±5.0
±1.0
2.0
±5.0
Max.
%
S
mA
Units
%
%
V
P-P
%
mS
°C
%
IOUT
Units
VAC
Output
Parameter
Output Current Accuracy
Line Regulation
Ripple & Noise (20 MHz)
Output Ripple Current
Hold-Up Time
Over Temperature Protection
Short Circuit Protection
Overload Protection
115 VAC 12.0
±10%, Autorecovery
85
Continuous (Autorecovery)
Autorecovery
95
Conditions
Min.
Input to Output 3,750
Input to FG 2,000
Output to FG
500
Input to Output
Input to FG 100 M
Output to FG
Typ.
107
Max.
General
Parameter
Isolation Voltage, 60S
Insulation Resistance
EMI Characteristics
Parameter
EMI
EMS
Surge
/ 500 VDC / 25°C / 70% RH
Standard
EN 55015; EN 6100-3-2, -3; FCC Part 18; CNS 14115; GB 17743
EN 61547; EN 61000-4-2,-3, -4, -5, -6, -8, -11; GB 17625.1
10 kV (L/N - FG), 5 kV (L-N)/1.2 x 50
µS
Min.
Typ.
Max.
-40
+25
+70
-40
+85
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing
95
Ambient
Conditions
Units
°C
°C
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Weight
See Mechanical Diagrams (Page 4)
32.1 Oz (950g)
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
220
kHours
See Note 5
50
kHours
UL 8750 Approved, Meets EN 61347, GB 19510.1, GB 19510.14
5 - 500 Hz, 1G , 1 Oct/Min, 2 Cycles, Period for 75 Min. Each Along X, Y, & Z Axis
Reliability Specifications
Parameter
MTBF
Life Expectancy
Safety Standards
Vibration
www.micropowerdirect.com

LDC-100-2740x Related Products

LDC-100-2740x LDC-100 LDC-100-1960x LDC-100-3560x LDC-100-2290x LDC-100-1650x
Description 100W Output Power 100W Output Power 100W Output Power 100W Output Power 100W Output Power 100W Output Power
[Video sharing] "AVR MCU Ten Days"
[i=s]This post was last edited by paulhyde on 2014-9-15 03:34[/i] [color=Blue][size=5]Xinshiji Electronics Teacher Adi's Microcontroller Series Video Tutorial "AVR Microcontroller Ten Days"[/size][/co...
open82977352 Electronics Design Contest
[Original article] 【R7F0C809】Summary of problems encountered in personal introduction
[Original article] [R7F0C809] Problems encountered in personal introduction 1. Error in importing examples, the model is not supportedSolution: Copy the Device_Custom folder in r7f0c809_dif to C:\Prog...
蓝雨夜 Renesas Electronics MCUs
Windows driver/dynamic library for CH372/CH375
Windows driver/dynamic library for CH372/CH375...
ham007 MCU
What is the difference between the two enable bits TACCIE and TAIE in the timer?
What is the difference between the two enable bits TACCIE and TAIE in the timer?...
ljk926 Microcontroller MCU
When executing the startup file, it is impossible to jump to the main function normally
When using AXD debugging, the program is burned and entered normally, but it cannot jump to the main function when running at full speed. The program ran successfully before, but I don’t know what cha...
qwerc NXP MCU
What exactly is JTAG?
What exactly is JTAG? JTAG (Joint Test Action Group) is an international standard test protocol (IEEE 1149.1 compatible), mainly used for internal chip testing. Most advanced devices now support the J...
yuandayuan6999 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1680  2923  2759  2823  2518  34  59  56  57  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号