Characteristics
RXM2AB2B7
miniature plug-in relay - Zelio RXM - 2 C/O - 24
V AC - 12 A - with LED
Main
Range of product
Series name
Product or component
type
Device short name
Contacts operation
Control circuit voltage
[Ithe] conventional
enclosed thermal
current
Status LED
Control type
Coil interference
suppression
Utilisation coefficient
Sale per indivisible
quantity
Zelio Relay
Miniature
Plug-in relay
RXM
Standard
24 V AC
12 A at <= 55 °C
With
Without
20 %
10
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Pushbutton
Complementary
[Ui] rated insulation voltage
250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
4 kV conforming to IEC 61000-4-5
Silver alloy (Ag/Ni)
12 A (AC-1/DC-1) conforming to UL
12 A (AC-1/DC-1) NO conforming to IEC
6 A (AC-1/DC-1) NC conforming to IEC
10 mA
250 V AC/DC
17 V
12 A at 250 V AC
12 A at 28 V DC
3000 VA, AC circuit
336 W, DC circuit
170 mW
<= 20 cyc/mn (under load)
<= 300 cyc/mn (no-load)
10000000 cycles
100000 cycles for resistive load
0.9 W, DC circuit
1.2, AC circuit
>= 0.1 Uc (DC
>= 0.15 Uc (AC
20 ms between coil de-energisation and making of the Off-delay contact (AC/DC)
20 ms between coil energisation and making of the On-delay contact (AC/DC)
180 Ohm, AC circuit at 20 °C +/- 15 %
19.2...26.4 V AC
RT I
Any position
21 mm
27 mm
[Uimp] rated impulse withstand voltage
Contacts material
[Ie] rated operational current
Minimum switching current
Maximum switching voltage
Minimum switching voltage
Resistive rated load
Maximum switching capacity
Minimum switching capacity
Operating rate
Mechanical durability
Electrical durability
Average consumption in W
Average consumption in VA
Drop-out voltage threshold
Operating time
Average resistance
Rated operational voltage limits
Protection category
Operating position
CAD overall width
CAD overall height
7/9/2011
1
CAD overall depth
Product weight
55 mm
0.037 kg
Environment
Dielectric strength
1500 V AC (between contacts)
1550 V AC (between coil and contact)
1550 V AC (between poles)
CSA
UL
CSA C22-2 No 14
EN/IEC 61810-1 (iss. 2)
UL 508
-40...85 °C
-40...55 °C
3 gn (f = 10...150 Hz), amplitude +/- 1 mm (on opening) conforming to EN/IEC
60068-2-27
5 gn (f = 10...150 Hz), amplitude +/- 1 mm (on closing) conforming to EN/IEC
60068-2-27
IP40 conforming to EN/IEC 60529
15 gn on closing conforming to EN/IEC 60068-2-27
15 gn on opening conforming to EN/IEC 60068-2-27
Compliant
0801
Product certifications
Standards
Ambient air temperature for storage
Ambient air temperature for operation
Vibration resistance
IP degree of protection
Shock resistance
RoHS EUR status
RoHS EUR conformity date
2
Product data sheet
Performance Curves
RXM2AB2B7
RXM Miniature Relays
Electrical Durability of Contacts
Durability (inductive load) = durability (resistive load) x reduction coefficient.
Resistive AC load
X
Y
A
B
C
D
Switching capacity (kVA)
Durability (Number of operating cycles)
RXM2AB•••
RXM3AB•••
RXM4ΑΒ•••
RXM4GΒ•••
Reduction coefficient for inductive AC load (depending on power factor cos ϕ)
Y
Reduction coefficient (A)
Maximum switching capacity on resistive DC load
X
Y
A
B
C
D
Voltage DC
Current DC
RXM2AB•••
RXM3AB•••
RXM4ΑΒ•••
RXM4GΒ•••
5