integrated high gain photo detector. The output of the
detector IC is an open collector Schottky-clamped
transistor. The internal shield provides a guaranteed
common mode transient immunity specification of 15
kV/µs.
This unique design provides maximum AC and DC
circuit isolation while achieving L V T T L / L V C M O S
compatibility. The optocoupler AC and DC operational
parameters are guaranteed from –40˚C to +85˚C
allowing trouble-free system performance.
Applications
• Isolated line receiver
• Computer-peripheral interfaces
• Microprocessor system interfaces
• Digital isolation for A/D, D/A conversion
• Switching power supply
• Instrument input/output isolation
• Ground loop elimination
• Pulse transformer replacement
• Fieldbus
Features
• Package clearance/creepage at 8 mm
• Low power consumption
• 15 kV/µs minimum Common Mode Rejection (CMR) at
V
CM
= 50 V
• High speed: 15 MBd typical
• LVTTL/LVCMOS compatible
• Low input current capability: 5 mA
• Guaranteed AC and DC performance over temperature:
–40˚C to +85˚C
• Available in 6-pin stretched SO-6 and 8 pin stretched
SO-8
• Safety approvals: UL, CSA, IEC/EN/DIN EN 60747-5-2 –
in process
Functional Diagram
ACPL-W60L
ANODE
1
2
CATHODE
3
6
5
4
V
CC
V
O
CATHODE
2
SHIELD
ACPL-K63L
ANODE
1
CATHODE
1
1
2
3
4
SHIELD
*
8
7
6
5
V
CC
V
O1
V
O2
GND
GND
ANODE
2
TRUTH TABLE
(POSITIVE LOGIC)
LED
ON
OFF
OUTPUT
L
H
*Advanced Information
A 0.1
µF
bypass capacitor must be
connected between pins 5 and 8.
CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to prevent
damage and/or degradation which may be induced by ESD.
Schematic Diagrams
I
F
1+
ACPL-W60L
I
CC
6
I
O
5
V
CC
ACPL-K63L
I
CC
1
V
O
I
F1
8
I
O1
7
V
CC
V
O1
+
V
F1
V
F
–
3
SHIELD
4
GND
–
2
SHIELD
3
–
I
O2
6
V
O2
USE OF A 0.1 µF BYPASS CAPACITOR CONNECTED
BETWEEN PINS 5 AND 8 IS RECOMMENDED (SEE NOTE 5).
V
F2
+
4
I
F2
SHIELD
5
GND
These optocouplers are suitable
for high speed logic interfacing,
input/output buffering, as line
receivers in environments that
conventional line receivers
cannot tolerate and are
recommended for use in
extremely high ground or induced
noise environments.
These optocouplers are available
in stretched SO-6 and SO-8
package. The part numbers are as
follows:
Package
Stretched SO-6
Stretched SO-8
Ordering Information
Specify Part Number followed by Option Number (if desired).
Example:
ACPL-W60L -XXXX
020 = UL5000 Vrms/minute Option
060 = IEC/EN/DIN EN 60747-5-2
500 = Tape and Reel Packaging Option
XXXE = Lead Free Option
Example:
ACPL-K63L -XXXX*
020 = UL5000 Vrms/minute Option – pending
qualification
060 = IEC/EN/DIN EN 60747-5-2
500 = Tape and Reel Packaging Option
XXXE = Lead Free Option
Option data sheets available. Contact Avago sales representative or
authorized distributor for information.
ACPL-W60L
ACPL-K63L
2
Package Outline Drawings
ACPL-W60L Stretched SO-6 Package
LAND PATTERN RECOMMENDATION
12.65 (0.498)
1.27 (0.050) BSG
0.381
±
0.127
(0.015
±
0.005)
1
2
3
6
5
4
+0.254
4.580 0
+0.010
0.180
-0.000
0.76 (0.030)
(
)
(
0.45 (0.018)
7°
+0.127
6.807 0
+0.005
0.268
-0.000
1.91 (0.075)
)
1.590
±
0.127
(0.063
±
0.005)
7°
45°
3.180
±
0.127
(0.125
±
0.005)
0.20
±
0.10
(0.008
±
0.004)
0.750
±
0.250
(0.0295
±
0.010)
11.50
±
0.250
(0.453
±
0.010)
DIMENSIONS IN MILLIMETERS (INCHES).
LEAD COPLANARITY = 0.1 mm (0.004 INCHES).
ACPL-K63L Stretched SO-8 Package
LAND PATTERN RECOMMENDATION
12.650 (0.5)
1.270 (0.050) BSG
0.381
±
0.13
(0.015
±
0.005)
1
2
3
4
8
7
6
5
+0.25
5.850 0
+0.010
0.230
-0.000
(
)
0.450 (0.018)
7°
1.590
±
0.127
(0.063
±
0.005)
45°
3.180
±
0.127
(0.125
±
0.005)
1.905 (0.1)
7°
0.200
±
0.100
(0.008
±
0.004)
0.750
±
0.250
(0.0295
±
0.010)
6.807
±
0.127
(0.268
±
0.005)
11.5
±
0.250
(0.453
±
0.010)
DIMENSIONS IN MILLIMETERS (INCHES).
LEAD COPLANARITY = 0.1 mm (0.004 INCHES).
3
Recommended Solder Reflow Thermal Profile
300
PREHEATING RATE 3°C + 1°C/–0.5°C/SEC.
REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC.
PEAK
TEMP.
245°C
PEAK
TEMP.
240°C
PEAK
TEMP.
230°C
2.5°C ± 0.5°C/SEC.
160°C
150°C
140°C
3°C + 1°C/–0.5°C
30
SEC.
30
SEC.
SOLDERING
TIME
200°C
TEMPERATURE (°C)
200
100
PREHEATING TIME
150°C, 90 + 30 SEC.
50 SEC.
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
0
0
50
100
150
200
250
TIME (SECONDS)
Note:
Use of non chlorine-activated fluxes is highly recommended.
Recommended PB-Free IR Profile
TIME WITHIN 5 °C of ACTUAL
PEAK TEMPERATURE
20-40 SEC.
t
p
T
p
T
L
260 +0/-5 °C
217 °C
RAMP-UP
3 °C/SEC. MAX.
150 - 200 °C
TEMPERATURE
T
smax
T
smin
RAMP-DOWN
6 °C/SEC. MAX.
t
s
PREHEAT
60 to 180 SEC.
25
t 25 °C to PEAK
t
L
60 to 150 SEC.
TIME
NOTES:
THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX.
T
smax
= 200 °C, T
smin
= 150 °C
Note:
Use of non chlorine-activated fluxes is highly recommended.
Regulatory Information
The ACPL-W60L//K63L have
been approved by the following
organizations:
UL - Pending
CSA - Pending
IEC/EN/DIN EN 60747-5-2 - Pending
Approval under CSA Component
Acceptance Notice #5, File CA
88324.
Approval under UL 1577,
Component Recognition
Program, File E55361.
4
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884
Teil 2):2003-01
(Option 060 only)
Insulation and Safety Related Specifications
Stretched
SO-6 and SO-8
Value
8
8
0.08
Parameter
Minimum External Air
Gap (External Clearance)
Minimum External Tracking
(External Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Symbol
L (101)
L (102)
Units
mm
mm
mm
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
CTI
175
Volts
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance, conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity.
DIN IEC 112/VDE 0303 Part 1
IIIa
Material Group (DIN VDE 0110, 1/89, Table 1)
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage
≤
150 V rms
for rated mains voltage
≤
300 V rms
for rated mains voltage
≤
600 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test
with t
m
= 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and Sample Test,
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
Case Temperature
Input Current
Output Power
Insulation Resistance at T
S
, V
IO
= 500 V
Symbol
Stretched S0-6 & SO-8 Value
I-IV
I-III
I-II
55/100/21
2
630
1181
Units
V
IORM
V
PR
V
peak
V
peak
V
PR
V
IOTM
945
6000
V
peak
V
peak
T
S
I
S,INPUT
P
S,OUTPUT
R
S
175
230
600
˚C
mA
mW
≥
10
9
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a detailed
description.
Note:
Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
[color=#3d3d3d][font="][size=14px]AD7476 is normal when it is first used in the circuit. After running for a period of time, the front-end analog input part is fixed at about 1V and remains unchanged....
Password Forgotten Password Clearance Manual 1. Crack the CMOS boot password To use a computer, you first need to turn it on. Therefore, the power-on password is the first thing we encounter. Although...
I compiled and generated a WINCE keyboard stream interface driver MYDRIVER.DLL. Where should I put it? How to compile it into the system? Please give me some advice. I have been struggling with this d...
[align=left][color=rgb(102, 102, 102)][font=Tahoma][size=3]#include"2407.h" int ADRESULT[16]; volatile unsigned int *j; //define a pointer variable J; int i=0x00,cesi; //shield interrupt subroutine vo...
I made a low-pass seventh-order elliptic filter. The theoretical cutoff frequency is 41M, but the measured value is only about 10M. Is there any better solution?...