MIL–PRF (CWR Style) Established Reliability – T429 Series CWR29 Style MIL–PRF–55365/11
Table 1 – Ratings & Part Number Reference
Rated
Voltage
VDC
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10
VDC
Rated
Cap
µF
2.2
3.3
4.7
4.7
6.8
6.8
10
10
15
15
22
22
33
33
33
47
68
68
100
100
150
220
330
1.5
3.3
3.3
4.7
4.7
6.8
6.8
10
10
15
15
15
22
22
22
33
47
47
68
68
68
100
150
220
330
1
µF
Case Code/
Case Size
KEMET/EIA
A/1005
A/1005
A/1005
B/1505
A/1005
C/2005
B/1505
D/1510
B/1505
E/2010
B/1505
D/1510
D/1510
E/2010
F/2214
E/2010
E/2010
G/2711
F/2214
H/2915
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
A/1005
C/2005
B/1505
D/1510
B/1505
E/2010
B/1505
D/1510
E/2010
D/1510
E/2010
F/2214
E/2010
F/2214
G/2711
F/2214
G/2711
H/2915
G/2711
G/2711
H/2915
H/2915
A/1005
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T429A225(1)004(2)(3)(4)
T429A335(1)004(2)(3)(4)
T429A475(1)004(2)(3)(4)
T429B475(1)004(2)(3)(4)
T429A685(1)004(2)(3)(4)
T429C685(1)004(2)(3)(4)
T429B106(1)004(2)(3)(4)
T429D106(1)004(2)(3)(4)
T429B156(1)004(2)(3)(4)
T429E156(1)004(2)(3)(4)
T429B226(1)004(2)(3)(4)
T429D226(1)004(2)(3)(4)
T429D336(1)004(2)(3)(4)
T429E336(1)004(2)(3)(4)
T429F336(1)004(2)(3)(4)
T429E476(1)004(2)(3)(4)
T429E686(1)004(2)(3)(4)
T429G686(1)004(2)(3)(4)
T429F107(1)004(2)(3)(4)
T429H107(1)004(2)(3)(4)
T429G157(1)004(2)(3)(4)
T429H227(1)004(2)(3)(4)
T429H337(1)004(2)(3)(4)
T429A155(1)006(2)(3)(4)
T429A335(1)006(2)(3)(4)
T429B335(1)006(2)(3)(4)
T429A475(1)006(2)(3)(4)
T429C475(1)006(2)(3)(4)
T429B685(1)006(2)(3)(4)
T429D685(1)006(2)(3)(4)
T429B106(1)006(2)(3)(4)
T429E106(1)006(2)(3)(4)
T429B156(1)006(2)(3)(4)
T429D156(1)006(2)(3)(4)
T429E156(1)006(2)(3)(4)
T429D226(1)006(2)(3)(4)
T429E226(1)006(2)(3)(4)
T429F226(1)006(2)(3)(4)
T429E336(1)006(2)(3)(4)
T429F476(1)006(2)(3)(4)
T429G476(1)006(2)(3)(4)
T429F686(1)006(2)(3)(4)
T429G686(1)006(2)(3)(4)
T429H686(1)006(2)(3)(4)
T429G107(1)006(2)(3)(4)
T429G157(1)006(2)(3)(4)
T429H227(1)006(2)(3)(4)
T429H337(1)006(2)(3)(4)
T429A105(1)010(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/11
Part Number
(See below for
part options)
CWR29C(3)225(1)(2)A(5)
CWR29C(3)335(1)(2)A(5)
CWR29C(3)475(1)(2)A(5)
CWR29C(3)475(1)(2)B(5)
CWR29C(3)685(1)(2)A(5)
CWR29C(3)685(1)(2)C(5)
CWR29C(3)106(1)(2)B(5)
CWR29C(3)106(1)(2)D(5)
CWR29C(3)156(1)(2)B(5)
CWR29C(3)156(1)(2)E(5)
CWR29C(3)226(1)(2)B(5)
CWR29C(3)226(1)(2)D(5)
CWR29C(3)336(1)(2)D(5)
CWR29C(3)336(1)(2)E(5)
CWR29C(3)336(1)(2)F(5)
CWR29C(3)476(1)(2)E(5)
CWR29C(3)686(1)(2)E(5)
CWR29C(3)686(1)(2)G(5)
CWR29C(3)107(1)(2)F(5)
CWR29C(3)107(1)(2)H(5)
CWR29C(3)157(1)(2)H(5)
CWR29C(3)227(1)(2)H(5)
CWR29C(3)337(1)(2)H(5)
CWR29D(3)155(1)(2)A(5)
CWR29D(3)335(1)(2)A(5)
CWR29D(3)335(1)(2)B(5)
CWR29D(3)475(1)(2)A(5)
CWR29D(3)475(1)(2)C(5)
CWR29D(3)685(1)(2)B(5)
CWR29D(3)685(1)(2)D(5)
CWR29D(3)106(1)(2)B(5)
CWR29D(3)106(1)(2)E(5)
CWR29D(3)156(1)(2)B(5)
CWR29D(3)156(1)(2)D(5)
CWR29D(3)156(1)(2)E(5)
CWR29D(3)226(1)(2)D(5)
CWR29D(3)226(1)(2)E(5)
CWR29D(3)226(1)(2)F(5)
CWR29D(3)336(1)(2)E(5)
CWR29D(3)476(1)(2)F(5)
CWR29D(3)476(1)(2)G(5)
CWR29D(3)686(1)(2)F(5)
CWR29D(3)686(1)(2)G(5)
CWR29D(3)686(1)(2)H(5)
CWR29D(3)107(1)(2)G(5)
CWR29D(3)157(1)(2)G(5)
CWR29D(3)227(1)(2)H(5)
CWR29D(3)337(1)(2)H(5)
CWR29F(3)105(1)(2)A(5)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Max/5 Min
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
2.0
3.0
3.0
4.0
4.0
6.0
8.0
10.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
3.0
3.0
4.0
4.0
4.0
6.0
10.0
10.0
20.0
1.0
µA @ +20ºC
Max/5 Min
DF
% @ +20ºC 120
Hz Max
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
10.0
10.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
8.0
6.0
8.0
8.0
6.0
8.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
6.0
% @ +20ºC 120
Hz Max
ESR
Ω @ +20ºC
100 kHz Max
4.0
6.0
6.0
3.2
6.0
2.2
3.2
1.3
3.2
1.0
3.2
1.3
1.3
0.9
0.6
0.9
0.9
0.275
0.55
0.18
0.25
0.20
0.18
4.0
6.0
3.2
6.0
2.2
3.2
1.5
3.2
1.0
3.2
1.7
0.9
1.7
1.0
0.6
1.0
1.0
0.275
0.4
0.25
0.18
0.275
0.275
0.18
0.18
5.0
Ω @ +20ºC
100 kHz Max
Moisture
Sensitivity
Reflow Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temperature
≤ 260ºC
Rated
Voltage
Rated Cap
Case Code/
Case Size
KEMET Part Number
MIL-PRF-55365/11
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
Surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, C = -55°C +85°C before Weibull or Z = None. Designates Surge
current option.
Refer to Ordering Information for additional detail.
Why does the timer of mspg2553 enter the interrupt every time? It seems that it can only enter once. I don't know what's the reason? ? ? ,, Can you help me?...
The circuit is as shown in the figure. For example, when I give IN1 a low level, other input indicators (D5, D7, D9) will flash, which will cause misjudgment. Although the program can filter it out by...
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
Introduction
In industrial control, speed measurement is often required. Generally, a contact tachometer is used. This tachometer must be placed against the center of the shaft to measure. It...[Details]
0 Introduction
Under normal circumstances, the three-phase power in the power system is symmetrical, and they meet certain amplitude and phase conditions; but when the load changes, the syst...[Details]
The DisplayPort interface standard is approved by the Video Electronics Standards Association (VESA) to provide an open, scalable standard for the entire industry. The development of DisplayPort ca...[Details]
Li/SOCl2 batteries (lithium sub-cells) have the advantages of high operating voltage, stable discharge voltage, wide operating temperature range and long storage life, and have been widely used in ...[Details]
System Block Diagram
The system uses DSP56F826 chip as the core control module and CMOS digital image sensor chip. The image acquisition resolution can reach 640×480 pixels. When high-re...[Details]
Introduction
Every year, cars are equipped with more complex electronic systems to maximize comfort, safety, and performance while minimizing harmful emissions. According to market resea...[Details]
This paper mainly studies the parallel current sharing technology of Droop method DC/DC converters, and designs a current sharing converter with parallel output of two DC/DC converters based ...[Details]
VGA (Video Graphics Array) is a graphics display standard proposed by IBM in 1987. Although it is no longer an advanced display standard, it is still widely used due to its mature technology and pr...[Details]
1. Introduction
The human balance ability is the basis for people to carry out various sports. People need balance ability to stand, sit, lie down, and walk. Once a person's balance ability is...[Details]
1 Introduction
With the development of transmission systems in recent years, multi-motor transmission systems have been widely used in various fields. In order to improve the dynamic performan...[Details]
The power consumption of digital cameras is a big problem. Even if you have enough batteries, it will cause a lot of trouble because you have to replace the batteries frequently, not to mention the...[Details]
Commonly used power management chips for portable products
●Low Dropout Regulators (LDO Linear Regulators)
LDO
VLDO;
●DC/DC Converters based on inductor energy...[Details]
Last week, Microsoft's Windows Phone 8 system was launched with great fanfare and attracted much attention from the industry. However, Nokia, the most staunch supporter of Microsoft's Windows Phone sy...[Details]
Google officially launched the new tablet Nexus 7 (center) and multimedia player Nexus Q (right).
MarketWatch reported on Wednesday (27th) that Google Inc. (GOOG-US) finally unveiled the t...[Details]