K = ±10% 006 = 6Vdc C = Std ESR S = 13" T&R L = Group A
represent
J = ±5%
010 = 10Vdc L = Low ESR W = Waffle
M = MIL (JAN)
significant
015 = 15Vdc
CWR11
figures 3rd
020 = 20Vdc
See page 6
digit represents
025 = 25Vdc
for additional
multiplier
035 = 35Vdc
(number of
packaging
zeros to follow)
050 = 50Vdc
options.
Reliability Grade
Qualification Termination Finish
Level
Weibull:
H = Solder Plated
0 = N/A
B = 0.1%/1000 hrs.
0 = Fused Solder
90% conf.
Plated
9 = SRC9000
C = 0.01%/1000 hrs.
8 = Hot Solder
90% conf.
Dipped
D = 0.001%/1000 hrs.
9 = Gold Plated
90% conf.
7 = Matte Sn
T = T Level
(COTS-Plus only)
Z = Non-ER
Not RoHS Compliant
LEAD-FREE COMPATI-
BLE
COMPONENT
For RoHS compliant products,
please select correct termination style.
CWR11 P/N CROSS REFERENCE:
CWR11
Type
D
Voltage
Code
C = 4Vdc
D = 6Vdc
F = 10Vdc
H = 15Vdc
J = 20Vdc
K = 25Vdc
M = 35Vdc
N = 50Vdc
^
Termination
Finish
H = Solder Plated
K = Solder Fused
C = Hot Solder
Dipped
B = Gold Plated
686
Capacitance
Code
pF code:
1st two digits
represent
significant
figures 3rd digit
represents
multiplier
(number of zeros
to follow)
*
Capacitance
Tolerance
M = ±20%
K = ±10%
J = ±5%
@
Reliability
Grade
Weibull:
B = 0.1%/1000 hrs.
90% conf.
C = 0.01%/1000 hrs.
90% conf.
D = 0.001%/1000
hrs. 90% conf.
T = T Level
A = Non-ER
+
Surge Test
Option
A = 10 cycles, +25°C
B = 10 cycles,
-55°C & +85°C
C = 10 cycles,
-55°C & +85°C
before Weibull
If blank,
None required
Packaging
Bulk = Standard
\TR = 7" T&R
\TR13 = 13" T&R
\W = Waffle
See page 6
for additional
packaging
options.
Not RoHS Compliant
SPACE LEVEL OPTIONS TO SRC9000*:
TBJ D
Type
Case
Size
686
*
006
C
L
@
9
^
++
Surge Test
Option
45 = 10 cycles,
-55ºC & +85ºC
before Weibull
Not RoHS Compliant
Capacitance Capacitance
Voltage
Standard or Packaging Inspection Level
Code
Tolerance
Code
Low ESR
L = Group A
B = Bulk
pF code:
M = ±20% 004 = 4Vdc
Range
R = 7" T&R
1st two digits
K = ±10% 006 = 6Vdc C = Std ESR S = 13" T&R
represent
J = ±5%
010 = 10Vdc L = Low ESR W = Waffle
significant
015 = 15Vdc
figures 3rd
020 = 20Vdc
See page 6
digit represents
025 = 25Vdc
for additional
multiplier
035 = 35Vdc
(number of
packaging
zeros to follow)
050 = 50Vdc
options.
Reliability Grade
Qualification Termination Finish
Level
Weibull:
H = Solder Plated
9 = SRC9000 0 = Fused Solder
B = 0.1%/1000 hrs.
90% conf.
Plated
C = 0.01%/1000 hrs.
8 = Hot Solder
90% conf.
Dipped
D = 0.001%/1000 hrs.
9 = Gold Plated
90% conf.
*Contact factory for AVX SRC9000 Space Level SCD details.
TECHNICAL SPECIFICATIONS
Technical Data:
Capacitance Range:
Capacitance Tolerance:
Rated Voltage: (V
R
)
Category Voltage: (V
C
)
Surge Voltage: (V
S
)
Temperature Range:
Unless otherwise specified, all technical data relate to an ambient
0.1 μF to 100 μF
±5%; ±10%; ±20%
4
6
10
16
20
25
35
2.7
4
6.7
10
13.3
16.7
23.3
5.3
8
13.3
20
26.7
33.3
46.7
3.5
5.3
8.7
13.3
17.8
22.2
31.1
-55°C to +125°C
temperature of 25°C
85°C:
125°C:
85°C:
125°C:
50
33.3
66.7
44.5
26
■
JUNE 2013
TBJ Series
CWR11 - MIL-PRF-55365/8
Established Reliability, COTS-Plus & Space Level
RATING & PART NUMBER REFERENCE
CWR11 P/N
CWR11C^225*@+
CWR11C^475*@+
CWR11C^685*@+
CWR11C^106*@+
CWR11C^156*@+
CWR11C^336*@+
CWR11C^686*@+
CWR11C^107*@+
CWR11D^155*@+
CWR11D^225*@+
CWR11D^335*@+
CWR11D^475*@+
CWR11D^685*@+
CWR11D^106*@+
CWR11D^156*@+
CWR11D^226*@+
CWR11D^476*@+
CWR11D^686*@+
CWR11F^105*@+
CWR11F^155*@+
CWR11F^225*@+
CWR11F^335*@+
CWR11F^475*@+
CWR11F^685*@+
CWR11F^156*@+
CWR11F^336*@+
CWR11F^476*@+
CWR11H^684*@+
CWR11H^105*@+
CWR11H^155*@+
CWR11H^225*@+
CWR11H^335*@+
CWR11H^475*@+
CWR11H^106*@+
CWR11H^226*@+
CWR11H^336*@+
CWR11J^474*@+
CWR11J^684*@+
CWR11J^105*@+
CWR11J^155*@+
CWR11J^225*@+
CWR11J^335*@+
CWR11J^475*@+
CWR11J^685*@+
CWR11J^156*@+
CWR11J^226*@+
CWR11K^334*@+
CWR11K^474*@+
CWR11K^684*@+
CWR11K^105*@+
CWR11K^155*@+
CWR11K^225*@+
CWR11K^335*@+
CWR11K^475*@+
CWR11K^685*@+
AVX COTS-Plus P/N
TBJA 225 * 004 C
TBJ A 475 * 004 C
TBJ B 685 * 004 C
TBJ B 106 * 004 C
TBJ B 156 * 004 C
TBJ C 336 * 004 C
TBJ D 686 * 004 C
TBJ D 107 * 004 C
TBJ A 155 * 006 C
TBJ A 225 * 006 C
TBJ A 335 * 006 C
TBJ B 475 * 006 C
TBJ B 685 * 006 C
TBJ B 106 * 006 C
TBJ C 156 * 006 C
TBJ C 226 * 006 C
TBJ D 476 * 006 C
TBJ D 686 * 006 C
TBJ A 105 * 010 C
TBJ A 155 * 010 C
TBJ A 225 * 010 C
TBJ B 335 * 010 C
TBJ B 475 * 010 C
TBJ B 685 * 010 C
TBJ C 156 * 010 C
TBJ D 336 * 010 C
TBJ D 476 * 010 C
TBJ A 684 * 015 C
TBJ A 105 * 015 C
TBJ A 155 * 015 C
TBJ B 225 * 015 C
TBJ B 335 * 015 C
TBJ B 475 * 015 C
TBJ C 106 * 015 C
TBJ D 226 * 015 C
TBJ D 336 * 015 C
TBJ A 474 * 020 C
TBJ A 684 * 020 C
TBJ A 105 * 020 C
TBJ B 155 * 020 C
TBJ B 225 * 020 C
TBJ B 335 * 020 C
TBJ C 475 * 020 C
TBJ C 685 * 020 C
TBJ D 156 * 020 C
TBJ D 226 * 020 C
TBJ A 334 * 025 C
TBJ A 474 * 025 C
TBJ B 684 * 025 C
TBJ B 105 * 025 C
TBJ B 155 * 025 C
TBJ C 225 * 025 C
TBJ C 335 * 025 C
TBJ C 475 * 025 C
TBJ D 685 * 025 C
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
Parametric Specifications by Rating per MIL-PRF-55365/8
Cap
DC Rated ESR @
DCL max
DF Max
@ 120Hz Voltage
100kHz
+25ºC
+85ºC
+125ºC
+25ºC
+(85/125)ºC
μF
V
Ohms
AVX SRC9000 P/N
Case
(μA)
(μA)
(μA)
(%)
(%)
@ 25ºC
@ +85ºC @ +25ºC
TBJ A 225 * 004 C L @ 0 ^ ++ A
2.2
4
8
0.5
5
6
6
9
TBJ A 475 * 004 C L @ 0 ^ ++ A
4.7
4
8
0.5
5
6
6
9
TBJ B 685 * 004 C L @ 9 ^ ++ B
6.8
4
5.5
0.5
5
6
6
9
TBJ B 106 * 004 C L @ 9 ^ ++ B
10
4
4
0.5
5
6
6
9
TBJ B 156 * 004 C L @ 9 ^ ++ B
15
4
3.5
0.6
6
7.2
6
9
TBJ C 336 * 004 C L @ 9 ^ ++ C
33
4
2.2
1.3
13
15.6
6
9
TBJ D 686 * 004 C L @ 9 ^ ++ D
68
4
1.1
2.7
27
32.4
6
9
TBJ D 107 * 004 C L @ 9 ^ ++ D
100
4
0.9
4
40
48
8
12
TBJ A 155 * 006 C L @ 9 ^ ++ A
1.5
6
8
0.5
5
6
6
9
TBJ A 225 * 006 C L @ 9 ^ ++ A
2.2
6
8
0.5
5
6
6
6
TBJ A 335 * 006 C L @ 9 ^ ++ A
3.3
6
8
0.5
5
6
6
9
TBJ B 475 * 006 C L @ 9 ^ ++ B
4.7
6
5.5
0.5
5
6
6
9
TBJ B 685 * 006 C L @ 9 ^ ++ B
6.8
6
4.5
0.5
5
6
6
9
TBJ B 106 * 006 C L @ 9 ^ ++ B
10
6
3.5
0.6
6
7.2
6
9
TBJ C 156 * 006 C L @ 9 ^ ++ C
15
6
3
0.9
9
10.8
6
9
TBJ C 226 * 006 C L @ 9 ^ ++ C
22
6
2.2
1.4
14
16.8
6
9
TBJ D 476 * 006 C L @ 9 ^ ++ D
47
6
1.1
2.8
28
33.6
6
9
TBJ D 686 * 006 C L @ 9 ^ ++ D
68
6
0.9
4.3
43
51.6
6
9
TBJ A 105 * 010 C L @ 9 ^ ++ A
1
10
10
0.5
5
6
4
6
TBJ A 155 * 010 C L @ 9 ^ ++ A
1.5
10
8
0.5
5
6
6
6
TBJ A 225 * 010 C L @ 9 ^ ++ A
2.2
10
8
0.5
5
6
6
9
TBJ B 335 * 010 C L @ 9 ^ ++ B
3.3
10
5.5
0.5
5
6
6
9
TBJ B 475 * 010 C L @ 9 ^ ++ B
4.7
10
4.5
0.5
5
6
6
9
TBJ B 685 * 010 C L @ 9 ^ ++ B
6.8
10
3.5
0.7
7
8.4
6
9
TBJ C 156 * 010 C L @ 9 ^ ++ C
15
10
2.5
1.5
15
18
6
6
TBJ D 336 * 010 C L @ 9 ^ ++ D
33
10
1.1
3.3
33
39.6
6
9
TBJ D 476 * 010 C L @ 9 ^ ++ D
47
10
0.9
4.7
47
56.4
6
9
TBJ A 684 * 015 C L @ 9 ^ ++ A
0.68
15
12
0.5
5
6
4
6
TBJ A 105 * 015 C L @ 9 ^ ++ A
1
15
10
0.5
5
6
4
6
TBJ A 155 * 015 C L @ 9 ^ ++ A
1.5
15
8
0.5
5
6
6
9
TBJ B 225 * 015 C L @ 9 ^ ++ B
2.2
15
5.5
0.5
5
6
6
9
TBJ B 335 * 015 C L @ 9 ^ ++ B
3.3
15
5
0.5
5
6
6
8
TBJ B 475 * 015 C L @ 9 ^ ++ B
4.7
15
4
0.7
7
8.4
6
9
TBJ C 106 * 015 C L @ 9 ^ ++ C
10
15
2.5
1.6
16
19.2
6
8
TBJ D 226 * 015 C L @ 9 ^ ++ D
22
15
1.1
3.3
33
39.6
6
8
TBJ D 336 * 015 C L @ 9 ^ ++ D
33
15
0.9
5.3
53
63.6
6
9
TBJ A 474 * 020 C L @ 9 ^ ++ A
0.47
20
14
0.5
5
6
4
6
TBJ A 684 * 020 C L @ 9 ^ ++ A
0.68
20
12
0.5
5
6
4
6
TBJ A 105 * 020 C L @ 9 ^ ++ A
1
20
10
0.5
5
6
4
6
TBJ B 155 * 020 C L @ 9 ^ ++ B
1.5
20
6
0.5
5
6
6
9
TBJ B 225 * 020 C L @ 9 ^ ++ B
2.2
20
5
0.5
5
6
6
8
TBJ B 335 * 020 C L @ 9 ^ ++ B
3.3
20
4
0.7
7
8.4
6
9
TBJ C 475 * 020 C L @ 9 ^ ++ C
4.7
20
3
1
10
12
6
8
TBJ C 685 * 020 C L @ 9 ^ ++ C
6.8
20
2.4
1.4
14
16.8
6
9
TBJ D 156 * 020 C L @ 9 ^ ++ D
15
20
1.1
3
30
36
6
8
TBJ D 226 * 020 C L @ 9 ^ ++ D
22
20
0.9
4.4
44
52.8
6
9
TBJ A 334 * 025 C L @ 9 ^ ++ A
0.33
25
15
0.5
5
6
4
6
TBJ A 474 * 025 C L @ 9 ^ ++ A
0.47
25
14
0.5
5
6
4
6
TBJ B 684 * 025 C L @ 9 ^ ++ B
0.68
25
7.5
0.5
5
6
4
6
TBJ B 105 * 025 C L @ 9 ^ ++ B
1
25
6.5
0.5
5
6
4
6
TBJ B 155 * 025 C L @ 9 ^ ++ B
1.5
25
6.5
0.5
5
6
6
8
TBJ C 225 * 025 C L @ 9 ^ ++ C
2.2
25
3.5
0.6
6
7.2
6
9
TBJ C 335 * 025 C L @ 9 ^ ++ C
3.3
25
3.5
0.9
9
10.8
6
8
TBJ C 475 * 025 C L @ 9 ^ ++ C
4.7
25
2.5
1.2
12
14.4
6
9
TBJ D 685 * 025 C L @ 9 ^ ++ D
6.8
25
1.4
1.7
17
20.4
6
9
-55ºC
(%)
9
9
9
9
9
9
9
12
9
9
9
9
9
9
9
9
9
9
6
9
9
9
9
9
9
9
9
6
6
9
9
9
9
9
9
9
6
6
6
9
9
9
9
9
9
9
6
6
6
6
9
9
9
9
9
25ºC
Dissipation
Ripple
A
W
(100kHz)
0.075
0.10
0.075
0.10
0.085
0.12
0.085
0.15
0.085
0.16
0.110
0.22
0.150
0.37
0.150
0.41
0.075
0.10
0.075
0.10
0.075
0.10
0.085
0.12
0.085
0.14
0.085
0.16
0.110
0.19
0.110
0.22
0.150
0.37
0.150
0.41
0.075
0.09
0.075
0.10
0.075
0.10
0.085
0.12
0.085
0.14
0.085
0.16
0.110
0.21
0.150
0.37
0.150
0.41
0.075
0.08
0.075
0.09
0.075
0.10
0.085
0.12
0.085
0.13
0.085
0.15
0.110
0.21
0.150
0.37
0.150
0.41
0.075
0.07
0.075
0.08
0.075
0.09
0.085
0.12
0.085
0.13
0.085
0.15
0.110
0.19
0.110
0.21
0.150
0.37
0.150
0.41
0.075
0.07
0.075
0.07
0.085
0.11
0.085
0.11
0.085
0.11
0.110
0.18
0.110
0.18
0.110
0.21
0.150
0.33
Power
Typical Ripple Data by Rating
85ºC
125ºC
25ºC
Ripple
Ripple
Ripple
A
A
V
(100kHz) (100kHz) (100kHz)
0.09
0.04
0.77
0.09
0.04
0.77
0.11
0.05
0.68
0.13
0.06
0.58
0.14
0.06
0.55
0.20
0.09
0.49
0.33
0.15
0.41
0.37
0.16
0.37
0.09
0.04
0.77
0.09
0.04
0.77
0.09
0.04
0.77
0.11
0.05
0.68
0.12
0.05
0.62
0.14
0.06
0.55
0.17
0.08
0.57
0.20
0.09
0.49
0.33
0.15
0.41
0.37
0.16
0.37
0.08
0.03
0.87
0.09
0.04
0.77
0.09
0.04
0.77
0.11
0.05
0.68
0.12
0.05
0.62
0.14
0.06
0.55
0.19
0.08
0.52
0.33
0.15
0.41
0.37
0.16
0.37
0.07
0.03
0.95
0.08
0.03
0.87
0.09
0.04
0.77
0.11
0.05
0.68
0.12
0.05
0.65
0.13
0.06
0.58
0.19
0.08
0.52
0.33
0.15
0.41
0.37
0.16
0.37
0.07
0.03
1.02
0.07
0.03
0.95
0.08
0.03
0.87
0.11
0.05
0.71
0.12
0.05
0.65
0.13
0.06
0.58
0.17
0.08
0.57
0.19
0.09
0.51
0.33
0.15
0.41
0.37
0.16
0.37
0.06
0.03
1.06
0.07
0.03
1.02
0.10
0.04
0.80
0.10
0.05
0.74
0.10
0.05
0.74
0.16
0.07
0.62
0.16
0.07
0.62
0.19
0.08
0.52
0.29
0.13
0.46
85ºC
Ripple
V
(100kHz)
0.70
0.70
0.62
0.52
0.49
0.44
0.37
0.33
0.70
0.70
0.70
0.62
0.56
0.49
0.52
0.44
0.37
0.33
0.78
0.70
0.70
0.62
0.56
0.49
0.47
0.37
0.33
0.85
0.78
0.70
0.62
0.59
0.52
0.47
0.37
0.33
0.92
0.85
0.78
0.64
0.59
0.52
0.52
0.46
0.37
0.33
0.95
0.92
0.72
0.67
0.67
0.56
0.56
0.47
0.41
125ºC
Ripple
V
(100kHz)
0.31
0.31
0.27
0.23
0.22
0.20
0.16
0.15
0.31
0.31
0.31
0.27
0.25
0.22
0.23
0.20
0.16
0.15
0.35
0.31
0.31
0.27
0.25
0.22
0.21
0.16
0.15
0.38
0.35
0.31
0.27
0.26
0.23
0.21
0.16
0.15
0.41
0.38
0.35
0.29
0.26
0.23
0.23
0.21
0.16
0.15
0.42
0.41
0.32
0.30
0.30
0.25
0.25
0.21
0.18
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
JUNE 2013
■
27
TBJ Series
CWR11 - MIL-PRF-55365/8
Established Reliability, COTS-Plus & Space Level
RATING & PART NUMBER REFERENCE
CWR11 P/N
CWR11K^106*@+
CWR11K^156*@+
CWR11M^104*@+
CWR11M^154*@+
CWR11M^224*@+
CWR11M^334*@+
CWR11M^474*@+
CWR11M^684*@+
CWR11M^105*@+
CWR11M^155*@+
CWR11M^225*@+
CWR11M^335*@+
CWR11M^475*@+
CWR11M^685*@+
CWR11N^104*@+
CWR11N^154*@+
CWR11N^224*@+
CWR11N^334*@+
CWR11N^474*@+
CWR11N^684*@+
CWR11N^105*@+
CWR11N^155*@+
CWR11N^225*@+
CWR11N^335*@+
CWR11N^475*@+
AVX COTS-Plus P/N
TBJ D 106 * 025 C
TBJ D 156 * 025 C
TBJ A 104 * 035 C
TBJ A 154 * 035 C
TBJ A 224 * 035 C
TBJ A 334 * 035 C
TBJ B 474 * 035 C
TBJ B 684 * 035 C
TBJ B 105 * 035 C
TBJ C 155 * 035 C
TBJ C 225 * 035 C
TBJ C 335 * 035 C
TBJ D 475 * 035 C
TBJ D 685 * 035 C
TBJ A 104 * 050 C
TBJ B 154 * 050 C
TBJ B 224 * 050 C
TBJ B 334 * 050 C
TBJ C 474 * 050 C
TBJ C 684 * 050 C
TBJ C 105 * 050 C
TBJ D 155 * 050 C
TBJ D 225 * 050 C
TBJ D 335 * 050 C
TBJ D 475 * 050 C
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
# @ 0 ^ ++
Parametric Specifications by Rating per MIL-PRF-55365/8
Cap
DC Rated ESR @
DCL max
DF Max
@ 120Hz Voltage
100kHz
+25ºC
+85ºC
+125ºC
+25ºC
+(85/125)ºC
μF
V
Ohms
AVX SRC9000 P/N
Case
(μA)
(μA)
(μA)
(%)
(%)
@ 25ºC
@ +85ºC @ +25ºC
TBJ D 106 * 025 C L @ 9 ^ ++ D
10
25
1.2
2.5
25
30
6
8
TBJ D 156 * 025 C L @ 9 ^ ++ D
15
25
1
3.8
38
45.6
6
9
TBJ A 104 * 035 C L @ 9 ^ ++ A
0.1
35
24
0.5
5
6
4
6
TBJ A 154 * 035 C L @ 9 ^ ++ A
0.15
35
21
0.5
5
6
4
6
TBJ A 224 * 035 C L @ 9 ^ ++ A
0.22
35
18
0.5
5
6
4
6
TBJ A 334 * 035 C L @ 9 ^ ++ A
0.33
35
15
0.5
5
6
4
6
TBJ B 474 * 035 C L @ 9 ^ ++ B
0.47
35
10
0.5
5
6
4
6
TBJ B 684 * 035 C L @ 9 ^ ++ B
0.68
35
8
0.5
5
6
4
6
TBJ B 105 * 035 C L @ 9 ^ ++ B
1
35
6.5
0.5
5
6
4
6
TBJ C 155 * 035 C L @ 9 ^ ++ C
1.5
35
4.5
0.5
5
6
6
8
TBJ C 225 * 035 C L @ 9 ^ ++ C
2.2
35
3.5
0.8
8
9.6
6
8
TBJ C 335 * 035 C L @ 9 ^ ++ C
3.3
35
2.5
1.2
12
14.4
6
8
TBJ D 475 * 035 C L @ 9 ^ ++ D
4.7
35
1.5
1.7
17
20.4
6
8
TBJ D 685 * 035 C L @ 9 ^ ++ D
6.8
35
1.3
2.4
24
28.8
6
9
TBJ A 104 * 050 C L @ 9 ^ ++ A
0.1
50
22
0.5
5
12
6
8
TBJ B 154 * 050 C L @ 9 ^ ++ B
0.15
50
17
0.5
5
6
4
6
TBJ B 224 * 050 C L @ 9 ^ ++ B
0.22
50
14
0.5
5
6
4
6
TBJ B 334 * 050 C L @ 9 ^ ++ B
0.33
50
12
0.5
5
6
4
6
TBJ C 474 * 050 C L @ 9 ^ ++ C
0.47
50
8
0.5
5
6
4
6
TBJ C 684 * 050 C L @ 9 ^ ++ C
0.68
50
7
0.5
5
6
4
6
TBJ C 105 * 050 C L @ 9 ^ ++ C
1
50
6
0.5
5
6
4
6
TBJ D 155 * 050 C L @ 9 ^ ++ D
1.5
50
4
0.8
8
9.6
6
8
TBJ D 225 * 050 C L @ 9 ^ ++ D
2.2
50
2.5
1.1
11
13.2
6
8
TBJ D 335 * 050 C L @ 9 ^ ++ D
3.3
50
2
1.7
17
20.4
6
9
TBJ D 475 * 050 C L @ 9 ^ ++ D
4.7
50
1.5
2.4
24
28.8
6
9
-55ºC
(%)
9
9
6
6
6
6
6
6
6
9
9
9
9
9
8
6
6
6
6
6
6
9
9
9
9
25ºC
Dissipation
Ripple
A
W
(100kHz)
0.150
0.35
0.150
0.39
0.075
0.06
0.075
0.06
0.075
0.06
0.075
0.07
0.085
0.09
0.085
0.10
0.085
0.11
0.110
0.16
0.110
0.18
0.110
0.21
0.150
0.32
0.150
0.34
0.075
0.06
0.085
0.07
0.085
0.08
0.085
0.08
0.110
0.12
0.110
0.13
0.110
0.14
0.150
0.19
0.150
0.24
0.150
0.27
0.150
0.32
Power
Typical Ripple Data by Rating
85ºC
125ºC
25ºC
Ripple
Ripple
Ripple
A
A
V
(100kHz) (100kHz) (100kHz)
0.32
0.14
0.42
0.35
0.15
0.39
0.05
0.02
1.34
0.05
0.02
1.25
0.06
0.03
1.16
0.06
0.03
1.06
0.08
0.04
0.92
0.09
0.04
0.82
0.10
0.05
0.74
0.14
0.06
0.70
0.16
0.07
0.62
0.19
0.08
0.52
0.28
0.13
0.47
0.31
0.14
0.44
0.05
0.02
1.28
0.06
0.03
1.20
0.07
0.03
1.09
0.08
0.03
1.01
0.11
0.05
0.94
0.11
0.05
0.88
0.12
0.05
0.81
0.17
0.08
0.77
0.22
0.10
0.61
0.25
0.11
0.55
0.28
0.13
0.47
85ºC
Ripple
V
(100kHz)
0.38
0.35
1.21
1.13
1.05
0.95
0.83
0.74
0.67
0.63
0.56
0.47
0.43
0.40
1.16
1.08
0.98
0.91
0.84
0.79
0.73
0.70
0.55
0.49
0.43
125ºC
Ripple
V
(100kHz)
0.17
0.15
0.54
0.50
0.46
0.42
0.37
0.33
0.30
0.28
0.25
0.21
0.19
0.18
0.51
0.48
0.44
0.40
0.38
0.35
0.32
0.31
0.24
0.22
0.19
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
Ask a newbie question: When drawing components in Altium Designer Summer 09, I set a pin to be hidden. As a result, every time I add a pin, it becomes hidden. I cancel the hidden attribute and add pin...
What is the maximum time that can be set with settimer()? I see in the function definition that the time parameter is in milliseconds and the type is UINT. So the maximum time that can be set is 65535...
0 Introduction
With the development of my country's economy, the number of motor vehicles continues to increase. The growth of existing roads and other hardware facilities can no longer meet t...[Details]
12v Lead Acid batteries used in trucks, cars, RVs and uninterruptible power supplies are usually rated at 12V. This circuit monitors the battery, the charge and discharge curves, gives the cu...[Details]
Among the many members of the single-chip microcomputer family, the MCS-51 series of single-chip microcomputers has occupied the main market of industrial measurement and control and automation eng...[Details]
From the previous section, we have learned that the timer/counter in the microcontroller can have multiple uses, so how can I make them work for the purpose I need? This requires setting the timer/...[Details]
Key Points
1. Now, in addition to high-end smartphones and tablets, users also expect to use touch screens in other applications, and they are gradually appearing in cars and instruments.
...[Details]
introduction
Steam turbines are driven by high-temperature and high-pressure steam generated by boilers to run at high speed. They are key power equipment in thermal power plants. The emergenc...[Details]
Introduction
Today, as IC (integrated circuit) has developed to a super-large scale, IC design based on IP (Intellectual Property) cores and their reuse are important means to ensure the ef...[Details]
As the global LED market demand continues to increase, my country's LED industry will face huge opportunities in the future. However, the core LED technology and patents are basically monopolized b...[Details]
1 Development of LED Film and Television Lighting
1.1 The significance of developing film and television lighting
Lighting power consumption accounts for a large proportion of the total p...[Details]
Zarlink Semiconductor has developed an ultra-low-power RF transceiver chip for pacemakers, neurostimulators, drug pumps, and other such implantable medical devices. It has high data rates, low power c...[Details]
1 Overview
In the field of traditional lighting, the concepts and definitions of lamps and lamps are clear. Lamps and lamps have their own applicable product standards, supporting technical st...[Details]
Mobile phones, MP3s, tablet computers, laptops, digital cameras, handheld game consoles, navigation devices, etc., all these mobile devices are powered by mobile batteries, and the battery life is ...[Details]
1. Advantages of CAN-bus in coal mine communication
Coal mine production is a field closely related to the national economy and people's livelihood. Among them, coal mine safety is undoubtedly ...[Details]
1 Introduction
Fieldbus is a serial, digital, multi-point communication data bus between field equipment/instruments installed in the production process area and automatic control devices/syst...[Details]
Today, fleet management innovation has made great progress. Whether trucks, buses, taxis or other means of transportation, wireless satellite positioning systems are used to enable dispatchers to u...[Details]