Data Sheet
November 9, 2006
EQD020 Series Single Output:
Eighth Brick Through-Hole Power Modules
19 - 60Vdc Input; 3.3Vdc Output; 66W
RoHS Compliant
Features
Compliant to RoHS EU Directive 2002/95/EC (-Z
versions
Compatible in a Pb-free or SnPb reflow environment
(-Z versions)
High efficiency – 90% at 48Vin, full load
Industry standard Eighth brick footprint and pin out
57.9 mm x 22.8 mm x 8.5 mm
(2.28 in. x 0.90 in. x 0.335 in.)
> 3:1 Input voltage range: 19 - 60 Vdc
Input under/overvoltage protection
Output overcurrent/voltage protection
Applications
Distributed power architectures
Wireless Networks
Optical and Access Network Equipment
Enterprise Networks
Over-temperature protection
Tightly regulated output
Remote sense
No reverse current during output shutdown
Negative logic, Remote On/Off
Output voltage trim ± 10%
Wide operating temperature range (-40°C to 85°C)
UL*
60950-1Recognized,
CSA
†
C22.2 No. 60950-1-
‡
03 Certified, and
VDE
0805:2001-12 (EN60950-1)
Licensed
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Licensed for Basic Insulation rating per EN60950-1
Options
Positive logic, Remote On/Off
Auto restart after fault protection shutdown
Heat plate
Case ground pin (with heat plate only)
Description
The EQD020 series DC-DC converters are a new generation of open-frame DC/DC power modules designed to
support a 3:1 input voltage range, that allows operation in both 24V or 48V nominal input voltage systems, thus
eliminating the need for separate power modules for each input voltage range. These single output DC-DC
converters operate over an input voltage range of 19 to 60 Vdc. The series is also designed to provide a tightly
regulated output voltage trim range of ± 10% V
O,Set
, with output current up to 20A at 3.3Vdc in an industry standard
eighth brick package. The output is isolated from the input, allowing versatile polarity configurations and grounding
connections. Built in filtering for both input and output minimizes the need for external filtering.
*
UL
is a registered trademark of Underwriters Laboratories, Inc.
†
‡
CSA
is a registered trademark of Canadian Standards Association.
VDE
is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
Document No: DS06-115 ver. 1.1
PDF name: eqd020_ds.pdf
Data Sheet
November 9, 2006
EQD020 Series Single Output: Eighth Brick Power Modules:
19-60 Vdc Input; 3.3Vdc Output; 66W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous, Operational
Transient, Operational (10mS minimum)
Transient , Non-operational (100 mS maximum)
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
I/O Isolation
Input – Output (100% factory Hi-Pot tested)
F
F
F
F
F
F
V
IN
V
IN, trans
V
IN, trans
T
A
T
stg
-40
-55
-0.3
60
75
100
85
125
1500
Vdc
Vdc
Vdc
°C
°C
Vdc
Device
Symbol
Min
Max
Unit
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
=0 to V
IN, max
, V
o
= V
o,set
, I
O
=I
O, max
)
Input Stand-by Current
Module on / off disabled (V
IN
= V
IN, nom
, V
o
= 0 V)
Input No Load Current
Module on / off enabled (V
IN
= V
IN, nom
, I
o
= 0 A)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance;
o
T
a
25 C, C
in
= 33µF)
Input Ripple Rejection (100 - 120Hz)
F
F
F
F
50
I
IN, NL
It
2
Device
F
F
Symbol
V
IN
I
IN,max
Min
19
Typ
24/48
Max
60
5
Unit
Vdc
Adc
F
I
IN, Stby
25
mA
110
1
30
mA
As
mAp-p
dB
2
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a very
fast-acting surface mount fuse with a maximum rating of 6.3 A (see Safety Considerations section). Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
Tyco Electronics Power Systems
2
Data Sheet
November 9, 2006
EQD020 Series Single Output: Eighth Brick Power Modules:
19-60Vdc Input; 3.3Vdc Output; 66W
Electrical Specifications
(continued)
Parameter
Output Voltage Set-point
(V
IN
= V
IN, min
=24/48, I
O
=I
O, max
, T
A
=25°C)
Output Voltage
(Over all line, load, and
Temp Conditions until end of life)
Output Regulation
Line (V
IN
= V
IN, min
to V
IN, max
)
Load (I
O
= I
O, min
to I
O, max
)
Temperature (T
ref
=T
A, min
to T
A, max
)
Output Ripple and Noise on nominal output
(V
IN
=V
IN, nom
and I
O
= I
O, min
to I
O, max
,
C
out
= 1μF ceramic // 10μF Tantalum capacitor)
RMS (5Hz to 20MHz bandwidth)
Peak-to-Peak (5Hz to 20MHz bandwidth)
External Capacitance
ESR
≥
10 mΩ
Output Current
Output Current Limit Inception (Hiccup Mode)
(V
o
= 90% V
o, set
)
Output Short-Circuit Current
V
O
≤
250 mV @ 25 C
Efficiency
V
IN
= 24V, T
A
=25°C, V
o
= 3.3V, I
O
= I
O, max
A
V
IN
= 48V, T
A
=25°C, V
o
= 3.3V, I
O
= I
O, max
A
Switching Frequency
Dynamic Load Response
(dIo/dt= 1A / 10μs; V
IN
= V
IN
, nom; TA=25°C,
Output Capacitance = 470 µF Polymer)
Load Change from Io= 50% Io,max to (50%±
25%) Io,max or from Io= (50%± 25%) Io,max to
50% Io,max
Peak Deviation
Settling Time (Vo<10% peak deviation)
F
Vpk
ts
⎯
⎯
3.5
200
4
300
%Vo
μs
F
F
F
η
η
f
sw
150
90
90
⎯
⎯
%
%
KHz
o
Device
F
F
Symbol
V
O, set
Min
-1.6
Typ
Max
+1.6
Unit
% V
O, set
V
O
-3
-
+3
% V
O
F
F
F
⎯
⎯
⎯
0.05
0.05
0.25
0.4
0.4
1
% V
O, nom
% V
O, nom
% V
O, nom
F
F
F
F
F
F
C
O
I
o
I
O, lim
I
O, s/c
⎯
⎯
0
0
105
⎯
5
50
⎯
20
80
5000
20
mV
rms
mV
pk-pk
μF
A dc
% I
o, max
% I
o, max
115
⎯
130
150
Isolation Specifications
Parameter
Isolation Capacitance
Isolation Resistance
Min
⎯
10
Typ
1000
⎯
Max
⎯
⎯
Unit
pF
MΩ
General Specifications
Parameter
Issue 1: Method 1 Case 3
Weight
Min
Typ
2,400,000
⎯
25.3 (0.89)
⎯
Max
Unit
Hours
g (oz.)
Calculated MTBF (I
O
=0.8I
O, max
, T
A
=30°C)
Telcordia SR-332
Tyco Electronics Power Systems
3
Data Sheet
November 9, 2006
EQD020 Series Single Output: Eighth Brick Power Modules:
19-60Vdc Input; 3.3Vdc Output; 66W
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
On/Off Signal interface
(V
IN
=V
IN, min
to V
IN, max
; Open collector or equivalent,
Signal referenced to V
IN
(-) terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low - On/Off Voltage
Logic Low - Remote On/Off Current
Logic High Voltage – (Typ = Open Collector)
Logic High maximum allowable leakage current
External voltage on ON/OFF Pin (to V
IN
(-) terminal)
Turn-On Delay and Rise Times
(I
O
=80 % I
O, max
, T
A
= 25 C)
Case 1: On/Off input is set to Logic High and then input
power is applied (delay from instant at which V
IN
= V
IN,
min
until V
o
=10% of V
o,nom
)
Case 2: Input power is applied for at least one second
and then the On/Off input is set to logic high (delay
from instant at which Von/Off = 0.9V until V
o
=10% of
V
o, set
)
Output voltage Rise time (time for Vo to rise from 10%
Of V
o, nom
to 90% of V
o, nom
)
Output voltage overshoot – Startup
I
O
= 80% of I
O, max
; T
A
= 25 C
Input Undervoltage Lockout
Turn-on Threshold
Turn-off Threshold
Hysteresis
Input Overvoltage Lockout
Turn-on Threshold
Turn-off Threshold
Hysteresis
Output Voltage Set point Adjustment
Output remote sense voltage range
(Max voltage drop is 0.33 V)
Output voltage adjustment range (TRIM)
Over voltage protection
Over Temperature Protection
At Vin = 24V
At Vin = 48V
F
F
F
F
V
TRIM
V
OV, set
T
ref
T
ref
2.97
3.8
125
117
3.63
4.5
Vdc
Vdc
°C
°C
F
V
SENSE
10
%
V
O,nom
F
V
OVLO
60
62
64
2
65
V
V
F
V
UVLO
16.2
1.5
18.6
16.6
19.0
V
V
o
o
Device
Symbol
Min
Typ
Max
Unit
F
F
F
F
F
V
IL
I
IL
V
IH
I
IH
V
ON/OFF
-0.7
―
―
―
―
―
―
―
1.2
1.0
5
50
13.5
V
mA
V
μA
V
F
T
delay
―
15
30
msec
F
T
delay
―
5
10
msec
F
F
T
rise
―
20
―
25
1
msec
% V
O, set
Tyco Electronics Power Systems
4
Data Sheet
November 9, 2006
EQD020 Series Single Output: Eighth Brick Power Modules:
19-60Vdc Input; 3.3Vdc Output; 66W
Characteristic Curves
The following figures provide typical characteristics for EQD020A at V
O
= 3.3 Vdc, I
O
= 20Adc, T
A
= 25
O
C
5
4
Io = 20A
Io = 10A
2
1
Io = 0.08A
0
15
25
35
45
55
65
V
O
(V) (10mV/div)
INPUT CURRENT, I
IN
(A)
3
INPUT VOLTAGE, V
IN
(V)
OUTPUT VOLTAGE
TIME, t (1 ms/div)
Figure 1. Typical Input characteristics.
95
90
Figure 4. Typical Output Ripple and Noise at V
IN
=
48V.
EFFICIENCY,
η
(%)
85
80
Vin = 24V
75
70
0
5
10
15
20
Vin = 48V
Vin = 60V
ON/OFF VOLTAGE
OUTPUT VOLTAGE
OUTPUT CURRENT, I
O
(A)
V
On/OFF
(V) (2V/div)
V
O
(V) (1.0 V/div)
Vin = 18V
TIME, t (5.0 ms/div)
Figure 2. Typical Converter Efficiency versus Output
Current.
Figure 5. Typical Start-Up Characteristics from
Remote ON/OFF at V
in
= 18V.
OUTPUT VOLTAGE
ON/OFF VOLTAGE
OUTPUT VOLTAGE
V
O
(V) (10mV/div)
TIME, t (1
μs/div)
V
On/OFF
(V) (2V/div)
V
O
(V) (1.0 V/div)
TIME, t (5.0 ms/div)
Figure 3. Typical Output Ripple and Noise at V
IN
=
24V.
Figure 6. Typical Start-Up Characteristics from
Remote ON/OFF at V
in
= 48V.
Tyco Electronics Power Systems
5