Part Number

Search

3191BC153M016BXS1

Description
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 15000uF, STUD MOUNT, CAN, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size362KB,4 Pages
ManufacturerCDE [ CORNELL DUBILIER ELECTRONICS ]
Environmental Compliance  
Download Datasheet Parametric View All

3191BC153M016BXS1 Overview

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 15000uF, STUD MOUNT, CAN, ROHS COMPLIANT

3191BC153M016BXS1 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCDE [ CORNELL DUBILIER ELECTRONICS ]
package instruction,
Reach Compliance Codecompli
ECCN codeEAR99
capacitance15000 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
dielectric materialsALUMINUM (WET)
ESR11.7 mΩ
Manufacturer's serial number3191
Installation featuresSTUD MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Package shapeCYLINDRICAL PACKAGE
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)16 V
ripple current10800 mA
surface mountNO
Terminal shapeBINDING POST
Type 3191
Aluminum Electrolytic, Screw Terminals, Switching and Audio Output
Screw Terminal Capacitors for Power Output Filtering
The low ESR of Type 3191 capacitors makes them
a great choice for output filtering in switching and
audio power supplies. It’s available with the capacitor
element potted in place for lowest cost or secured by
rill, spoon shaped dimples in the side of the can. Rilled
construction offers high vibration and shock with-
standing and excellent heat transfer for higher ripple
current.
Outline Drawing
Highlights
Stud mount available
High current application
Industrial applications
Smoothing and filtering
Audio power supplies
Specifications
Operating Temperature:
Rated Voltage:
Capacitance Range:
Capacitance Tolerance:
Ripple Current Multipliers
–40 to + 85 ºC
7.5 Vdc to 55 Vdc
2700 µF to 150000 µF
–10 to + 30%; –10 to +50%; ±20%
Ambient Temperature
Temperature
I
R
Multiplier
45 ºC
2.24
60 Hz
0.90
55 ºC
2.00
120 Hz
1.00
65 ºC
1.73
300 Hz
1.05
75 ºC
1.41
85 ºC
1.00
Frequency
Frequency
I
R
Multiplier
1000 Hz
≥10
Khz
1.10
1.15
Life Test:
Shelf Life:
Vibration:
Complies with the EU Directive
2002/95/EC requirement restricting
the use of Lead (Pb), Mercury (Hg),
Cadmium (Cd), Hexavalent chromium
(Cr(VI)), PolyBrominated Biphenyls
(PBB) and PolyBrominated Diphenyl
Ethers (PBDE).
Endurance, 1500 h at rated voltage and 85 ºC
Δ Capacitance: ±10%
ESR ≤ 200% of limit
DCL ≤ 100% of limit
Storage, 500 h at 85 ºC
Δ Capacitance: ±10%
ESR ≤ 175% of limit
DCL ≤ 200% of limit
10 to 500 Hz, 0.75 mm or 10 g* if less,
3 directions, 2 h ea
Δ Capacitance: ±5%
no visible damage or leakage
*15 g if rilled construction
CDM Cornell Dubilier • 140 Technology Place. • Liberty, SC • 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
(Urgent) How can I use malloc and free functions under ads? ? Waiting online!! (without OS)
Urgent, urgent, urgent, urgent!!! How can I use malloc and free functions in ads? ? ? In the absence of OS... Please give me some advice!!...
aug_com Embedded System
If you want to find a job or change jobs, look here and find a safe haven in the winter.
Hello everyone, I’m Dolphin from Shanghai KT Talent. Our company is one of the largest and most professional integrated circuit talent consulting companies in China. For many years, we have been focus...
dolphinsrf Recruitment
Digital power supply, you will definitely make it! --- Start with a "fool" power supply!
[i=s]This post was last edited by dontium on 2015-3-19 17:34[/i] [align=left][size=4] [/size][/align][align=left][size=4] [/size][/align][align=left][size=4][font=宋体] Digital power supply, it sounds a...
dontium Power technology
Question: How to turn off the screen?
We want to achieve this effect: turn off the screen display (not just the backlight), I can achieve this with the following method [code] ... HDC gdc; int iESC=SETPOWERMANAGEMENT; gdc = ::GetDC(NULL);...
glancegreen Embedded System
Zigbee connection to the cloud, please help!
Zigbee is connected to the cloud, and the data sent to the cloud is correct. Why can't the corresponding chart values of the Onenet cloud application management be displayed, such as temperature and h...
cyct RF/Wirelessly
Introduction to Wireless Power Consortium Standards and +TI+ Compatible Solutions pdf
[size=5][color=red][b][/b][/color][/size]...
qwqwqw2088 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1206  2255  558  224  7  25  46  12  5  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号