Power/Signal Relay, 4PDT, Momentary, 0.022A (Coil), 110VDC (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
CategoryMechanical and electronic products    relay   
File Size359KB,4 Pages
ManufacturerSTPI Siege Social
Download Datasheet Parametric View All

326400DP110 Overview

Power/Signal Relay, 4PDT, Momentary, 0.022A (Coil), 110VDC (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount

326400DP110 Parametric

Parameter NameAttribute value
MakerSTPI Siege Social
Reach Compliance Codeunknown
ECCN codeEAR99
body width26 mm
body height25.7 mm
Body length or diameter26 mm
Maximum coil current (DC)0.022 A
Coil operating voltage (DC)75 V
Coil release voltage (DC)5 V
Coil resistance5000 Ω
Maximum coil voltage (DC)110 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load10A@115VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
JESD-609 codee4
Manufacturer's serial number326
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours11 ms
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
physical size26mm X 26mm X 25.7mm
Relay actionMOMENTARY
Relay function4PDT
Relay typePOWER/SIGNAL RELAY
release time11 ms
sealHERMETICALLY SEALED
surface mountNO
Terminal surfaceGOLD
Termination typeSOLDER
326 4
RT -
4
PDT
/10
A
327 4
RT -
4
PDT
/15
A
RELAIS HERMETIQUES
MONOSTABLES
HERMETICALLY SEALED
NON LATCHING
RELAY
CARACTERISTIQUES GENERALES
326
Combinaison des contacts
Contact arrangement
GENERAL CHARACTERICS
327
4 RT
4 PDT
4 RT
4 PDT
Pouvoir de coupure 28 Vcc - 1 5 V/400 Hz
1
Contact rating 28 Vdc - 115 V/400 Hz
Circuit résistif
Resistive load
10 A
10 Amps
1 A
5
15 Amps
Circuit inductif (L/R = 5 ms)
Inductive load (L/R = 5 ms)
8A
8 Amps
10 A
10 Amps
Circuit moteur
Motor load
4A
4 Amps
6A
6 Amps
Circuit lampe
Lamp load
2A
2 Amps
3A
3 Amps
Alimentation
Supply
Courant continu (polarisé) ou courant alternatif 50/400Hz ou 50/60Hz ou 400Hz
Direct current (polarized) or alternative current 50 /400 Hz or 50/60 Hz or 400 Hz
Masse
Weight
70 g à 76 g max.
70 g to 76 g max.
Normes applicables en annexe
See appendice for applicable specifications
ENVIRONNEMENT
Température de fonctionnement
Temperature range
ENVIRONMENT
- 65° à + 1
25°C
- 65° to + 125°C
Position de fonctionnement
Operating position
Indifférente
Any
Tenue aux vibrations
Resistance against vibrations
Sinus : 30 g - 10 - 3 000 Hz / Aléatoire : 0,4 g
2
/Hz - 50 - 2 000 Hz
Sinus : 30 g - 10 - 3 000 Hz / Random : 0,4 g
2
/Hz - 50 - 2 000 Hz
Tenue aux chocs
Shocks resistance
200 g - 6 ms / 100 g - 1 ms
1
200 g - 6 ms / 100 g - 11 ms
Tenue aux secousses
Shake resistance
40 g
40 g
Accélération
Acceleration
20 g
20 g
Taux de fuite
Leak rate
< 1.10
-8
cm
3
/sec
< 1.10
-8
cm
3
/sec
58 Av. Claude VELLEFAUX - 75010 PARIS - FRANCE
326 1/4
51
Tel : 33.(0)1.42.03.94.20 - Fax : 33.(0)1.42.03.52.85 - www.stpigroup.com
AVR RAM expansion method
AVR RAM expansion method...
lorant Embedded System
Q: What determines the amplifier power supply voltage range? What are the mainstream power supply ranges?
A: When choosing an amplifier, the power supply range is the first indicator to be determined. This is determined by the application requirements. For example, if the power supply of other devices in ...
guojian047 Analog electronics
Is there any way to remove the leading zeros in the numbers displayed in the edit control in ucgui?
When using the edit control to display data in real time, I found that there are always zeros in front of the numbers that cannot be removed, like the followingIs there any way to remove all the zeros...
哥从不解释 Real-time operating system RTOS
Everyone, please join my programming and hardware exchange group 72651142
Everyone, please join my programming and hardware exchange group 72651142...
tang_lixin Embedded System
Will vxworks automatically generate a default route?
After starting vxworks, I used routeshow to find that there is already a routing table entry. The gateway of this entry is the IP of the machine's own BIOS. I would like to ask, is this automatically ...
qsyx Real-time operating system RTOS
Book exchange
[size=6]I wonder how many core coins I can get from Da Xia to buy a copy of Professor Xia Yuwen's Verilog book? [/size]...
shelion FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1549  2341  1237  181  1311  32  48  25  4  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号