The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
2.
The operating characteristics are measured at a coil temperature of 23°C.
3.
The maximum voltage is the highest voltage that can
be
imposed on the Relay coil instantaneously.
G6JU-Y Single coil, Latching (G6JU-2P-Y, G6JU-2FL-Y, G6JU-2FS-Y)
Rated voltage
(VDC)
3
4.5
5
12
Rated current
(mA)
33.7
22.0
20.4
9.0
Coil resistance
(Ω)
89.0
204.3
245.5
1,329.2
Set voltage
75% max.
Reset voltage
% of rated voltage
75% max.
150% max.
Max. voltage
Power
consumption (mW)
100
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
2.
The operating characteristics are measured at a coil temperature of 23°C.
3.
The maximum voltage is the highest voltage that can
be
imposed on the Relay coil instantaneously.
44
Surface-mounting Relay
G6J-Y
■
Characteristics
Item
Contact resistance (See note 1)
Operating (set) time (See note 2)
Release (reset) time (See note 2)
Minimum set/reset pulse width
Insulation resistance (See note 3)
Dielectric strength
Standard non-latching relays
G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y
100 mΩ max.
3 ms max. (approx. 1.6 ms)
3 ms max. (approx. 1.0 ms)
---
1,000 MΩ min. (at 500 VDC)
1,500 VAC, 50/60 Hz for 1 min.
between
coil and contacts
1,000 VAC, 50/60 Hz for 1 min.
between
contacts of different polarity
750 VAC, 50/60 Hz for 1 min.
between
contacts of the same polarity
Surge withstand voltage
Vibration
Shock
Service life
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
Ambient temperature
Humidity
Weight
Note: 1.
2.
3.
4.
2,500 VAC, (2 x 10
μs)
between
coil and contacts
1,500 VAC, (10 x 160
μs)
between
contacts of the same and different polarity
10 to 55 Hz, 5-mm double amplitude
10 to 55 Hz, 3.3-mm double amplitude
1,000 m/s
2
(approx. 100G)
750 m/s
2
(approx. 75G)
50,000,000 operations min. (at 36,000 operations/hour)
100,000 operations min. (with a rated load at 1,800 operations/hour)
−40
to 85°C with no icing or condensation
5% to 85% RH
Approx. 1.0 g
The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
Values in parentheses are typical values unless otherwise stated.
The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those for checking the dielectric strength.
The above values are initial values.
3 ms max. (approx. 0.9 ms)
10 ms min. (at 100% rated coil voltage)
Single coil latching relays
G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y
Surface-mounting Relay
G6J-Y
45
Characteristic Data
Maximum Switching Capacity
Switching current (A)
10
7
5
3
Ambient Temperature vs.
Maximum Voltage
Maximum voltage (%)
250
Ambient Temperature
vs. Switching Current
Switching current (A)
1.2
200
1
0.8
150
0.6
100
AC resistive load
1
0.7
0.5
0.3
DC resistive load
0.4
50
0.2
0.1
1
3
5
10
30 50
100
300 500 1,000
0
−40
−20
0
20
40
60
80
100
0
−40
−20
0
20
40
60
80
100
Switching voltage (V)
Ambient temperature (°C)
Ambient temperature (°C)
Note:
“Maximum voltage” is the maximum voltage that can
be
applied to the Relay coil.
Electrical Life Expectancy
Switching operations (x10
4
operations)
1,000
500
300
Ambient Temperature vs. Must
Shock Malfunction
Operate or Must Release Voltage
Change rate on the
basis
of rated voltage (%)
100
90
80
70
60
50
200
40
30
20
10
Operating voltage
Release voltage
−40
−20
0
20
40
60
80 100
max.
avg.
min.
1,000
Z'
Shock directions
X
X'
Y
Z
Z'
Y'
400
600
800
1,000
Unit: m/s
2
Sample: G6J-2P-Y
Number of Relays: 10
1,000
X'
Maximum estimated value
max.
avg.
min.
Y
1,000
800
X
1,000
600 Not
energized
400
200
Z
1,000
Energized
100
50
30
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
10
5
3
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Y'
1
0
0.2
0.4
0.6
0.8
1
1.2
0
−60
Switching current (A)
Ambient temperature (°C)
Conditions: Shock is applied in
±X, ±Y,
and
±Z
directions
three times each with and without energizing the Relays
to check the number of contact malfunctions.
Electrical Life Expectancy (with
Must Operate and Must Release
Voltage) (See note.)
On the
basis
of rated voltage (%)
100
Sample: G6J-2P-Y
Number of Relays: 10
Test conditions: 1-A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/hour
Electrical Life Expectancy
(Contact resistance) (See note.)
Contact resistance (mΩ)
Sample: G6J-2P-Y
Number of Relays: 10
Test conditions: 1-A resistive load
500
at 30 VDC with an operation rate
of 50% Switching frequency:
1,800 operations/hour
Contact Reliability Test
(See note.)
Contact resistance (mΩ)
1,000
Sample: G6J-2P-Y
Number of Relays: 10
Test conditions: 10
μA
resistive load
500
at 10 m VDC with an operation rate
of 50% Switching frequency: 7,200
operations/hour
1,000
NO contact
NC contact
NO contact
NC contact
80
max.
min.
300
300
60
Operate voltage
100
max.
40
min.
Release voltage
20
50
30
Contact resistance
max.
max.
min.
min.
100
max.
max.
50
30
Contact resistance
min.
min.
0
0.001 0.01
0.1
1
10
100
1,000
10
0.001 0.01
0.1
1
10
100
1,000
10
0.001 0.01
0.1
1
10
100
1,000
Operating frequency (x10
3
operations)
Operating frequency (x10
3
operations)
Operating frequency (x10
5
operations)
Note:
1.
2.
The tests were conducted at an ambient temperature of 23°C.
The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary according
to the switching frequency and operating environment, so
be
sure to check operation under the actual operating conditions
I successfully ordered TMDX5535EZDSP on estore, but there has been no response after half a month. The order status is still processing. I asked twice on the customer message page on the website but t...
The booming development of the Internet of Vehicles in recent years has led to a continuous increase in the proportion of vehicles with Internet connectivity in the new car market. According to their ...
Hi everyone, I encountered the problem "failed to refresh PTF file" in SOPC Builder. Some people on the Internet said to change the network card number, but I changed it several times and it still hap...
After reviewing, I found that "ARM Cortex-M0 Starts Here" has a lot of printing errors. I apologize again for the inconvenience caused to readers. I post the errata sheet, hoping to minimize the impac...