Part Number

Search

BK1/GDA-1A

Description
Electric Fuse, Fast Blow, 1A, 250VAC, 1500A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size250KB,2 Pages
ManufacturerEaton
Download Datasheet Parametric View All

BK1/GDA-1A Overview

Electric Fuse, Fast Blow, 1A, 250VAC, 1500A (IR), Inline/holder,

BK1/GDA-1A Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codecompli
ECCN codeEAR99
Fusing characteristicsFAST
body height20 mm
Body length or diameter5.2 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal
Installation featuresINLINE/HOLDER
method of packingBAG
physical size5.2mm x 20mm
Rated breaking capacity1500 A
Rated current1 A
Rated voltage (AC)250 V
GuidelineCCC; SEMKO; UL
surface mountNO
Terminal surfaceNICKEL
Terminal shapeEND CAP
5 x 20mm Fuses
GDA Series, Fast-Acting, Ceramic Tube
Description
• Fast-acting, high breaking capacity
• 5 x 20mm physical size
• Ceramic tube, nickel-plated brass endcap construction
• Silver-plated endcap construction (50mA-400mA)
• Optional axial leads are 0.032" x 1.5" copper tinned
• Designed to IEC 60127-2
Electrical Characteristics
1.5 In 2.1 In
2.75 In
4 In
10 In
In
min
max
min
max
min
max
max
50mA-3.15A 60 min 30 min 10 ms 2 sec 3 ms 300 ms 20 ms
4A-10A
60 min 30 min 10 ms 3 sec 3 ms 300 ms 20 ms
Dimensions - mm
Drawing Not to Scale
Agency Information
• UL Recognized Card: Guide JDYX2, File E19180
• CSA Component Acceptance: File 53787
• Semko Approval: File 413779, File 512433
• IMQ Approval: File EB405
• CCC: File 2005010207155691
Ordering
Specify product code
• Insert packaging code prefix before part number. E.g.
BK/GDA-250mA
Specify option code if desired
• For axial leads, insert “V” between catalog series and
amp rating. E.g. BK/GDA-V-250mA
• With TR2 packaging code, lead wire length is 19.05mm
Specifications
Part Number
GDA-50mA
GDA-63mA
GDA-80mA
GDA-100mA
GDA-125mA
GDA-160mA
GDA-200mA
GDA-250mA
GDA-315mA
GDA-400mA
GDA-500mA
GDA-630mA
GDA-800mA
GDA-1A
GDA-1.25A
GDA-1.6A
GDA-2A
GDA-2.5A
GDA-3.15A
GDA-4A
GDA-5A
GDA-6.3A
Voltage Interrupting Rating (amps)
Typical DC
Typical
Typical
Rating at Rated Voltage (50Hz) Cold Resistance Melting I
2
t Voltage
Vac
Vac
(Ω)*
(amps) Drop (mV)‡
250
1500
157.5
0.0017
9000
250
1500
39.0
0.0005
3300
250
1500
27.9
0.0011
2600
250
1500
20.0
0.0018
2300
250
1500
12.3
0.0037
1900
250
1500
8.5
0.008
1600
250
1500
6.0
0.020
1350
250
1500
4.4
0.027
1300
250
1500
3.3
0.010
1400
250
1500
2.2
0.018
1200
250
1500
0.460
0.038
1050
250
1500
0.340
0.064
1200
250
1500
0.245
0.097
490
250
1500
0.231
0.146*
330
250
1500
0.176
0.313*
297
250
1500
0.113
0.748*
239
250
1500
0.073
2.0
205
250
1500
0.053
3.9
190
250
1500
0.037
8.1
160
250
1500
0.027
14
160
250
1500
0.019
25
155
250
1500
0.014
48
150
IMQ
X
Agency Approvals
SEMKO
UR
CCC
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CSA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X**
X**
X**
X**
X**
X
‡ Typical Voltage Drop (Voltage drop was measured at 20ºC ambient temperature at rated current)
*I
2
t of 1A, 1.25A, 1.6A is measured at 10In DC.
**CSA Approvals on these ratings will not be marked on the fuse cap.
0209
BU-SB08725
Page 1 of 2
Data Sheet 2014
Use of wireless data transmission module
I need to buy a wireless data transmission module recently to transmit GPS differential station signals. However, after looking at many wireless data transmission modules, I found that many of them cl...
jasenmax Embedded System
Please provide the PDF documentation about ALTIUM DESIGNER.
[font=仿宋_GB2312][size=4]Sometimes my computer cannot access the Internet, so it is very troublesome to view some functions. I want to change these options to PDF that can be viewed locally. Please tel...
lzcqust PCB Design
2553 serial port baud rate problem help
I set the clock to 1MHz and the baud rate to 38400, but the data I sent out and received back were all some incomprehensible Chinese characters. What should I do?...
飞扬跋扈 Microcontroller MCU
The STM32F205 microcontroller reads and writes the ferroelectric memory FM22L16 through the FSMC, and the data is offset
[font=宋体][size=3]The STM32F205 microcontroller reads and writes the ferroelectric memory FM22L16 through FSMC. When I run the program directly, I first write a certain length of data into the memory a...
mo_正_pei stm32/stm8
【Play with LaunchPad】Communication interface experiment
This series of documents would like to thank forum members wstt, david_lee, cat3902982, sugerlatu, zhangdaoyu and other friends for their strong support. They spent a lot of time and energy to organiz...
EEWORLD社区 Microcontroller MCU
Good, I'm working hard, thanks for your advice
Good, I'm working hard, thanks for your advice...
游客 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1853  19  1945  2438  2006  38  1  40  50  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号