EEWORLDEEWORLDEEWORLD

Part Number

Search

804-003-00ZNU6-1GB

Description
Circular Connector, 1 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size377KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

804-003-00ZNU6-1GB Overview

Circular Connector, 1 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,

804-003-00ZNU6-1GB Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompli
ECCN codeEAR99
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellYES
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceZINC-NICKEL WITH CHROMATE PLATED
Shell materialALUMINUM ALLOY
Housing size6
Termination typeCRIMP
Total number of contacts1
A
B
C
In-Line
804-003-01
Rear Panel Jam Nut Mount
804-003-07
Front Panel Jam Nut Mount
804-003-00
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
Series 804
Series 804 “Mighty Mouse”
Push-Pull Quick-Disconnect
Series 804 Receptacles – Crimp Termination
Integral Band Platform
for direct attachment of a cable
shield. Install a boot, or overmold a boot over the band
platform. An accessory thread is available for attaching
strain reliefs and backshells.
Three Shell Options:
Jam nut with o-ring for front or rear
panel mounting, or in-line receptacles for free-hanging cables.
HOW TO ORDER
Sample Part Number
80 4- 0 0 3
Series
-0 1
Shell Style
M
Shell Material /
Finish
C
Aluminum / Black
Anodize
7-10
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
12-2
12-37
14-55
15-85
P
Contact Type
Shell Key
Position
Omit
for Single
Master Key
M
-00
804-003
Receptacle with
Banding Platform
Jam Nut for Front
Panel Mounting
Aluminum / Electroless
Nickel
NF
Aluminum / Cadmium
with Olive Drab
Chromate
ZN
-01
In-Line for Free-
Hanging Cable
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
804-004
Receptacle with
Accessory Thread
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
3 #23 Contacts
P
1 #16 Contact
Pin
4 #23 Contacts
S
7 #23 Contacts
Socket
1 #12 Contact
10 #23 Contacts
Standard #23 contacts
accept #22 through
13 #23 Contacts
#28 AWG wire. Special
4 #16 Contacts
contacts for #26 to #30
19 #23 Contacts
AWG are available. Use
26 #23 Contacts
the following contact
2 #12 Contacts
codes to specify these
contacts:
37 #23 Contacts
55 #23 Contacts
G
85 #23 Contacts
Pin #2630
A
Pos. A
(Normal)
B
Pos. B
C
Pos. C
H
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
D
Pos. D
Socket #2630
Z1
-07
Jam Nut for Rear
Panel Mounting
Stainless Steel /
Passivated
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
G-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Loongson Chinese Documentation
Loongson data sheet in Chinese! Check out the domestic IP core, compare the price with ARM's advantages and disadvantages! Support domestic products! I haven't been here for a long time. After seeing ...
tashanshi MCU
How stable is RT-Thread?
Recently, we are evaluating the stability of RT, especially the real-time performance and time certainty under heavy pressure. RT-Thread is stable to a large extent. After all, RTOS is not out of reac...
freebsder Embedded System
Can memory sticks be poisonous?
Why did the shutdown interface change after I added a 512-megapixel memory stick?...
linhuanhuan Embedded System
I2C loses bus control and waits for emergency
When I2C reads the 9250 module, the data is always 0. The device ID can sometimes be read and sometimes not. I enter my I2C write byte function and find that the program is stuck in while(!(I2CMasterE...
627933142 Microcontroller MCU
When I do thermal transfer printing on a PCB myself, if I don't have a thermal transfer machine, can I use a large iron block to press down the thermal transfer paper and blow it with a hot air gun?
As the title says, since I don't have a thermal transfer printer, I only have a heat gun. After watching the thermal transfer process, I think it should be possible....
赵怡彬 PCB Design
WinCE built-in database application problem
The following is a small program I wrote. When running, it always fails to enter the branch of the switch statement, that is, there is no prompt for Refreshing11!. The data has been stored in the data...
hao43 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2490  767  2106  1646  2578  51  16  43  34  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号