EEWORLDEEWORLDEEWORLD

Part Number

Search

HGN-365A01W-17-1JT

Description
1A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOCKET
CategoryThe connector    The connector   
File Size473KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance
Download Datasheet Parametric View All

HGN-365A01W-17-1JT Overview

1A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOCKET

HGN-365A01W-17-1JT Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPower Dynamics, Inc.
Reach Compliance Codecompli
Other featuresSTANDARDS: IEC 60320; UL; VDE
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings1A, 115/250VAC
Manufacturer's serial numberHGN-365A
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
HGN-365A
IEC 60320 INLET SOCKET WITH SINGLE OR DOUBLE FUSE HOLDER,
SNAP-IN OR FLANGE MOUNT
MECHANICAL DIMENSIONS
(Unit: mm)
SNAP-IN
30.8
28.3
28.5
31.0
33.0
35.0
32.3
Use only with a 250V Fuse
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
FEATURES
The HGN-365A filter series offers a wide variety of options
with a current rating up to 10A, 250VAC. This power entry
module offers industry standard 5 x 20mm fuse/s with IEC
connector. This series offers an option of having a single or
double fuse in the same package. These filters are also used
for health care equipment and offer extremely low leakage
current to comply with UL544 & 2602.
A Ground Choke can be added to enhance the grounding
ability of the circuit. A bleeder resistor can also be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
2x
6
33.0
Use only with a 250V Fuse
42.6
48.5
(58.4)
6.3
27.8
31.0
FLANGE MOUNT
28.3
36.0
28.0 Max
31.0
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
2x
3.6
32.4 Typ.
2x
3.6
RECOMMENDED
PANEL CUTOUT
(MOUNTING FROM FRONT)
36.0
44.0
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 4A, 6A, 8A, 10A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA
@ 250VAC 50Hz: 1.0mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
Panel Thickness 1mm to 1.6mm
(58.4)
48.5
42.6
6.3
27.8
31.0
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
70
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
Thoughts after reading sunhong's post: How do you treat reference design?
I was also inspired by sunhong's post, so I hope everyone can discuss it. I remember that at this time last year, I interviewed a senior executive of NEC China, who is Chinese. Therefore, he inevitabl...
向农 Talking about work
After timer0 is turned on, tss=1 cannot be turned off. I want to turn off the timer now. Can you please help me?
[color=#000][font=Arial, Helvetica, sans-serif][size=12px] void delay(unsigned int x) { count=x; CpuTimer0Regs.TCR.bit.TSS=0; This is a delay program, using timer interrupt for delay. When delay is ca...
jonny0811 Microcontroller MCU
{STM32F429i development board} received and unharmed
I saw friends on the forum had broken cables, and I was worried for several days. I received it at noon today and opened the box immediately. Wow, lucky~~~ It came out intact. I guess the LCD cable is...
47857872 stm32/stm8
Supermarket CCTV Monitoring System Solution
I. System composition and distribution 1. Closed-circuit monitoring system In response to the requirements of a chain supermarket, the following supermarket closed-circuit television monitoring system...
呱呱 RF/Wirelessly
Newbie, please give me some advice!
I want to output num in half a clock cycle, using the following statement always@(posedge clk or posedge clk_re) num<=count; clk_re is the inverse signal of clk. There is a problem with the compilatio...
eeleader FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2900  1107  1864  2787  2303  59  23  38  57  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号