Description
DC-DC Converter UNIT 1.8 W REGULATED DC-DC CONVERTER
File Size221KB,5 Pages
ManufacturerPower Systems GmbH & Co. KG
Websitehttp://www.power-systems.de
Download Datasheet View All

HRS-0515 Overview

DC-DC Converter UNIT 1.8 W REGULATED DC-DC CONVERTER

DC-DC Converter UNIT
HR Series
( 1.8 W REGULATED DC-DC CONVERTER )
FEATURES
1000VDC ISOLATION
HIGH EFFICIENCY
INTERNAL FILTERING
LOW COST
NO EXTERNAL COMPONENTS
REQUIRED
UP TO 1.8W REGULATED OUTPUT
POWER
DUAL IN LINE PACKAGE
100% BURNED IN
LOW NOISE
MTBF > 850,000 HOURS
OUTPUT SPECIFICATIONS
Voltage Setpoint Accuracy
Temperature Coefficient
Ripple & Noise (20MHz
BW)
Line Regulation
1
Load Regulation
2
Short Circuit Protection
Short Circuit Restart
+/-0.5% max
+/-0.5% max
Current Limit
Protection
Automatic
+/-2% max
+/-0.03%/
O
C
100mVp-p max
INPUT SPECIFICATIONS
Input Voltage Range
Input Filter
+/-10% max
Capacitor Type
GENERAL SPECIFICATIONS
Efficiency
Isolation Voltage
3
Isolation Resistance
Switching Frequency
Isolation Capacitance
MTBF
Weight
50% min
1000 VDC min
9
10 ohms min
25 KHz min
80pF max
850,000 Hours
10.1g Typ
Non-Conductive Plastic
32.5mm*17mm*10.2mm
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Cooling
-25
O
C to +71
O
C
-55
O
C to +125
O
C
Free-Air Convection
ALL SPECIFICATIONS TYPICAL AT NOMINAL
LINE,
FULL
LOAD
,
AND
25
O
Case Material
Case Size
C
UNLESS
OTHERWISE NOTED.
1
2
3
High Line to Low Line.
Load Regulation is for output load current change from 0% to 100%.
For 60 seconds
www.Power-Systems.de
Page: 1 / 5
Version: 4-Oct-02
and r2,r2,#0x0ffff doesn't work! How to clear the high half?
It says Immediate 0x0000ffff out of range for this operation. Of course, I didn't read the Reference Manual too carefully. Please help me....
haoya84 Embedded System
Array operations
[i=s] This post was last edited by dontium on 2015-1-23 13:42 [/i] I am a beginner in DSP and I am using 6713. This morning I wrote a simple program to add two arrays. The specific program is as follo...
maq9627 Analogue and Mixed Signal
Working process of ADC
[color=#333333][font=arial, Simsun, 宋体][size=12px]I've been studying the ADC module of XC2000 recently. I don't understand the principle of the ADC module at all. So reading the manual is like reading...
1157421908 Analogue and Mixed Signal
New Year's Day is coming! Do you have any plans to travel?
New Year's Day is coming! Do you have any plans to travel?...
蓝雨夜 Talking
Change Win10 system to Win7 usage habits
[align=left][font=黑体][size=3][b]What system are you using? Since I changed to a new system, I always feel uncomfortable with it. I have found many ways on the Internet to turn Win10 into Win7. This me...
谢飞机 Embedded System
Problems with upgrading wince5.0 to 6.0: (expert help~~~~~~~~)
I am new to wince and am porting 2440BSP5.0 to 6.0. I get the following error when compiling OAl. I don't understand. I hope you can help me analyze it. Thanks in advance! ! BUILD: [Thrd:Sequence:Type...
qjc221 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1244  2171  2907  1642  2836  26  44  59  34  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号