EEWORLDEEWORLDEEWORLD

Part Number

Search

247XCXL-18F24VDC

Description
Off-Delay Relay, 3PDT, Momentary, 0.104A (Coil), 24VDC (Coil), 2500mW (Coil), 10A (Contact), 28VDC (Contact), 18s, DC Input, AC/DC Output, Through Hole-Straight Mount
CategoryMechanical and electronic products    relay   
File Size447KB,2 Pages
ManufacturerStruthers-Dunn
Download Datasheet Parametric View All

247XCXL-18F24VDC Overview

Off-Delay Relay, 3PDT, Momentary, 0.104A (Coil), 24VDC (Coil), 2500mW (Coil), 10A (Contact), 28VDC (Contact), 18s, DC Input, AC/DC Output, Through Hole-Straight Mount

247XCXL-18F24VDC Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
ECCN codeEAR99
body width37.2 mm
body height95.2 mm
Body length or diameter66.8 mm
Maximum coil current (DC)0.104 A
Coil operating voltage (DC)19.2 V
Coil power2500 mW
Coil resistance230.77 Ω
Maximum coil voltage (DC)24 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load10A@240VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)240 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
timed delay18 s
Manufacturer's serial number247
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
physical size66.8mm X 37.2mm X 95.2mm
GuidelineCSA; UL
Relay actionMOMENTARY
Relay function3PDT
Relay typeOFF-DELAY RELAY
surface mountNO
Termination typeSOLDER
Base Number Matches1
246/247 Series - Timer Delay Relay
DPDT, 4PDT,6PST, 10 Amp
Rugged, industrial time delay versions of the popular 219 series. Contacts can be configured up
to four pole double throw or six pole single throw. Time ranges are adjustable over a 1:10 range.
Knob adjustment and integral hold down clip are standard. A large option list makes this product
easily customized for special applications.
E13224
GENERAL SPECIFICATIONS (@ 25° C)
Timing:
Functions Available
Time Range
Timing Adjustment
Timing Repeatability
(Constant voltage and temperature)
Reset Time maximum
Input Pulse Length minimum
Contacts:
Contact Configuration
Contact Material
Contact Rating
120 / 240VAC Resistive
28VDC Resistive
Motor 120VAC
Motor 240VAC
Minimum Contct Load
Contact Resistance, Initial
Coil:
Coils Available
Nominal Coil Power
Input Voltage Tolorance -AC
Input Voltage Tolorance -DC
Transient Protection
Reverse Polarity Protection
Duty
Dielectric Strength:
Across Open Contacts
Between Mutally Insulated Points
Insulation Resistance
Temperature:
Operating
Storage
Life Expectancy:
Electrical (full load operations)
Mechanical (no load operations)
Miscellaneous:
Mounting Position
Mating Socket
Accessories
Enclosure
Weight
On-delay, Off-delay
Up to 10 minutes
Knob
3%
150mS
50mS
DPDT, 4PDT, 6PST
Silver Alloy Gold Diffused
10 Amp / 5 Amp
10 Amp
-
-
500mW
100 milliohms max @ 6VDC, 1A
AC and DC
5VA 2.5W
85% to 110% of nominal
80% to 110% of nominal
Yes
Yes
Continuous
500Vrms
1500Vrms
1,000 Mohms min @ 500VDC
-20 to 70°C (-4 to 158°F)
-40 to 105°C (-40 to 221°F)
100,000
10,000,000
Any
12 pin =27390, 27390D
14 pin = 33377, 33377D
Hold down clip integral to relay
Clear Polycarbonate
8.6oz (244 grams)
with socket
Industrial Pin Out
Note: SM = Single make
DM = Double make
Voltage
Make
Carry
Resistive Inductive
120VAC
30 Amp 10 Amp 10 Amp
3 Amp
240VAC
30 Amp 10 Amp 5 Amp
1 Amp
24VDC
30 Amp 10 Amp 10 Amp
5 Amp
28VDC
30 Amp 10 Amp 10 Amp
3 Amp
125VDC
30 Amp 10 Amp 0.5 Amp
0.1 Amp
For versions with suffix “69” permant magnet blowouts
Voltage
Make
Carry
Resistive Inductive
125VDC (SM) 30 Amp 10 Amp 1.5 Amp
0.5 Amp
125VDC (DM) 30 Amp 10 Amp
4 Amp
1.5 Amp
250VDC (SM) 30 Amp 10 Amp
0.5 Amp 150 mAmp
250VDC (DM) 30 Amp 10 Amp 1.5 Amp
0.5 Amp
246/247 Contact Load Specifications
7/9
www.struthers-dunn.com
(843) 664-3303
FATFS f_read()
I used the FATFS in TI's official demo char buffer[6000]; res = f_open(&file,"ma.bmp", FA_OPEN_ALWAYS | FA_READ); //Define ma.bmp as existing, read if(res==FR_OK) { res = f_read(&file, buffer, sizeof(...
mawenruinb ARM Technology
How to calculate the transformation ratio of a multi-channel output transformer
I just started to get in touch with switching power supplies recently, and found that the transformer in the flyback switching power supply circuit often has multiple outputs. So is the ratio of the o...
sizumiyazhao Analog electronics
EEWORLD Forum 2014 Week 8 (2.17-2.23) Highlights
[align=left][font=微软雅黑][size=3][b][align=left]The following ranking is in no particular order. It is just a small review of the wonderful posts on the forum last week. The purpose is to help more neti...
eric_wang Energy Infrastructure?
"FlashDownloadFailed-"Cortex-M3" often appears when debugging stm32
Causes and solutions for Error: Flash download failed-"Cortex-M3" in MDKThis problem usually occurs when the Flash programming algorithm in MDK is not configured or not configured correctly.Open the F...
kwoklee stm32/stm8
Problems of electromagnetic flowmeter in daily water supply application
1. Power supply problem Since the electromagnetic flowmeter needs an external power supply, it is inconvenient to install it outdoors, which also limits the use of electromagnetic flowmeters in suburb...
cfybhd Sensor
Programming Questions
How to use 89C52 to control three ultrasonic distance measurement programs? ? Urgent... I have the main program, or can you help me modify it......
etfengyun 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 172  1116  1172  537  408  4  23  24  11  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号