Out-of-Band Networking
Datasheet
LX Series
5250 Power Control Series
The 5250 Power Control Series from MRV Communications delivers
AC power solutions combining intelligent power distribution and remote
power control. A key element of MRV’s Out-of-Band Network solutions,
is providing a powerful, cost-effective approach for remote networks
and systems to ensure minimal operational downtime and eliminate
site visits.
Applications
• Enterprise data centers
• Remote/branch offices
• Test and development labs
• Utilities
Simple, Secure Remote Network Operations
The 5250 Power Control Series allows administrators to remotely power-
on, power-off or reboot equipment and monitor power consumption.
The 5250 models are accessible through MRV’s LX Series Console
Servers with enhanced security capabilities, including SSH v2, SNMP V3,
Radius, SecurID, TACACS+, and are FIPS 140 certified. The LX Series
provides management through an easy to use browser-based GUI,
extensive command line interface, and MRV’s SNMP based MegaVision
management platform.
The LX Series features allows sophisticated site specific power
management automation. The Trigger/Action feature of the LX Series
allows site administrators to easily automate physical and security
infrastructure control. Additional applications include controlling power
access for lab automation, turning on additional air conditioning
when needed, or controlling individual power outlets by department or
scheduled activity.
Benefits
• Combine power distribution and remote power management
• Single management interface for service port management and
remote power control
• Easy to use graphical browser interface, Command Line Interface
and SNMP based management options
• Industry leading security features, including Radius, SecurID,
TACACS+, and more.
• Only remote power management vendor to support US
government FIPS 140 security standard.
Mobile
Access
Cent
ralized
Operations
Key Features
• Power cycle individual power outlets to remotely reboot servers
and network devices, anywhere in the world. Or, power-off
unused power receptacles
• High Power Distribution: 120V, 208V, 240V and three-phase
power options. 20 or 30-Amp power input feed
• 8, 16, 24 or 32 ports
• Vertical or horizontal mounting models
• Group outlets by name, within a unit, or across multiple units
• Access controlled through standard security infrastructure,
including Radius, SecurID, TACACS+, LDAP, or local database
• Power-up Sequencing: Prevent an in-rush power overload
• Input Current Monitor: Measure the aggregate current draw on
each power circuit monitor using LED digital display or remotely
• Automated alerts though SNMP, pager, SMS
Manage
d
Elements
Dial On
Demand
Private Net/Internet
Console
Server
S
Conta
ct
Sensors
~
Critical
Elements
Power
Management
sales@mrv. com
Out-of-Band Networking
Datasheet
Model Number
LX-5250-8H1C20
LX-5250-8H1L30
LX-5250-8H2C20
LX-5250-8H2L30
LX-5250-16V1C20
LX-5250-16V1L30
LX-5250-16V2C20
LX-5250-16V2L30
LX-5250-24V2C20
LX-5250-24V2L30
LX-5250-24VYL20
LX-5250-24VYL30
LX-5250-32V1C20
LX-5250-32V1L30
LX-5250-32V2C20
LX-5250-32V2L30
LX-5250-8HEC20
LX-5250-16VEC20
LX-5250-16VEP32
LX-5250-24VEC20
LX-5250-24VEP32
LX-5250-32VEC20
Outlets Amps Outlet Type
8
8
8
8
16
16
16
16
24
24
24
24
32
32
32
32
8
16
16
24
24
32
20A
30A
20A
30A
20A
30A
20A
30A
20A
30A
20A
30A
20A
30A
20A
30A
16A
16A
32A
16A
32A
16A
NEMA 5-20R
NEMA 5-20R
IEC 60320/C13
IEC 60320/C13
NEMA 5-20R
NEMA 5-20R
IEC 60320/C13
IEC 60320/C13
IEC 60320/C13
IEC 60320/C13
IEC 60320/C13
IEC 60320/C13
NEMA 5-20R
NEMA 5-20R
IEC 60320/C13
IEC 60320/C13
IEC 60320/C13
IEC 60320/C13
IEC 60320/C13
IEC 60320/C13
IEC 60320/C13
IEC 60320/C13
Input Voltages
100-120V 50-60Hz
100-120V 50-60Hz
200-240V 60Hz
200-240V 60Hz
100-120V 50-60Hz
100-120V 50-6-Hz
208-240V 60Hz
208-240V 60Hz
208-240V 60Hz
208-240V 60Hz
3-Phase 208V 60Hz
3-Phase 208V 60Hz
100-120V 50-60Hz
100-120V 50-60Hz
208-240V 60Hz
208-240V 60Hz
230V 50-60Hz
230V 50/60Hz
230V 50/60Hz
230V 50-60Hz
230V 50/60Hz
230V 50-60Hz
Input Type
IEC 60320/C20 Inlet
NEMA L5-30P Cordset
IEC 60320/C20 Inlet
NEMA L6-30P Cordset
IEC 60320/C20 Inlet
NEMA L5-30P Cordset
IEC 60320/C20 Inlet
NEMA L6-30P Cordset
IEC 60320/C20 Inlet
NEMA L6-30P Cordset
NEMA L21-20P Cordset
NEMA L21-30P Cordset
IEC 60320/C20 Inlet
NEMA L5-30P Cordset
IEC 60320/C20 Inlet
NEMA L6-30P Cordset
IEC 60320/C20 Inlet
IEC 60320/C20 Inlet
IEC 60309 Cordset
IEC 60320/C20 Inlet
IEC 60309 Cordset
IEC 60320/C20 Inlet
Dimensions
1.75” x 17” x 7”
1.75” x 17” x 7”
1.75” x 17” x 7”
1.75” x 17” x 7”
44.5” x 1.75” x 3.0”
44.5” x 1.75” x 3.0””
49.5” x 1.75” x 3.0”
49.5” x 1.75” x 3.0”
69.0” x 1.75” x 3.0”
69.0” x 1.75” x 3.0”
69.0” x 1.75” x 3.0”
69.0” x 1.75” x 3.0”
63.5” x 3.5” x 2.25”
63.5” x 3.5” x 2.25”
63.5” x 3.5” x 2.25”
63.5” x 3.5” x 2.25”
1.75” x 17” x 7”
49.5” x 1.75” x 3.0”
49.5” x 1.75” x 3.0”
69.0” x 1.75” x 3.0”
69.0” x 1.75” x 3.0”
63.5” x 3.5” x 2.25”
European Models - RoHS Compliant
Specifications
Network Interface
Serial Interface
Operating Temperature
Storage Temperature
Humidity
10/100 BaseT Ethernet
RS-232, modular RJ-45
32° to 122° F (0° to 50° C)
-40° to 185° F (-40° to 85° C)
10 to 90%, non-condensing
FCC Part 15, Class A
US / Canada (cTUVus mark) to UL 60950-
1:2003 and CAN/CSA 22.2 No. 60950-1-03
European Union (TUVGS mark) to EN 60950-
1:2001
CE
EMC-EN55022 Class A, EN 55024
Power Inlet Cord Options
LX-5250-PCORD1
LX-5250-PCORD2
LX-5250-PCORD3
LX-5250-PCORD4
LX-5250-PCORD5
LX-5250-PCORD6
LX-5250-PCORD7
IEC 60320/C19 - NEMA L6-20P, 10’
IEC 60320/C19 - SHUKO 10’
IEC 60320/C19 - IEC 60309
(BS4343, CEE17) 16/20A BLUE
(UK Commando)
IEC 60320/C19 - BS1363 13A (UK) 10’
IEC 60320/C19 - 5-15P
(15A Straight -Blade) 10’
IEC 60320/c19 - 5-20P
(20A Straight-Blade) 10’
IEC 60320/C19 - L5-20P
(20A Twist-Lock) 10’
Certifications
MRV has more than 50 offices throughout the world. Addresses, phone numbers, and fax numbers are listed at www.mrv.com.
Please e-mail us at sales@mr v. com or call us for assistance.
MRV (West Coast USA)
20415 Nordhoff St.
Chatsworth, CA 91311
800-338-5316
818-773-0900
MRV (East Coast USA)
295 Foster St.
Littleton, MA 01460
800-338-5316
978-952-4700
MRV (International)
Business Park Moerfelden
Waldeckerstrasse 13
64546 Moerfelden-Walldorf
Germany
Tel. (49) 6105/2070
Fax. (49) 6105/207-100
All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness
thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information. MRV Communications and the MRV Communications
logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders.
Copyright ©2006 MRV Communications, Inc. All Rights Reserved.