EEWORLDEEWORLDEEWORLD

Part Number

Search

PMB01DM24

Description
CARLO GAVAZZI - PMB01DM24 - TIME DELAY RELAY; DPDT; 100H; 240VAC/DC
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size133KB,4 Pages
ManufacturerETC2
Download Datasheet Compare View All

PMB01DM24 Online Shopping

Suppliers Part Number Price MOQ In stock  
PMB01DM24 - - View Buy Now

PMB01DM24 Overview

CARLO GAVAZZI - PMB01DM24 - TIME DELAY RELAY; DPDT; 100H; 240VAC/DC

Timers
Multifunction
Types DMB01, PMB01
• Time range 0.1 s to 100 h
• 7 knob selectable functions:
Op -
delay on operate
In
-
interval
Io
-
interval on trigger open
Id
-
double interval
Dr
-
delay on release
R
-
symmetrical recycler ON first
Rb -
symmetrical recycler OFF first
• Knob selection of time range
• Knob-adjustable time setting
• Automatic or manual start
• Repeatability:
0.2%
• Output: 8 A SPDT or 8 A DPDT relay
• For mounting on DIN-rail in accordance with DIN/EN
50 022 or Plug-in
• 22.5 mm Euronorm or 36 mm Plug-in module housing
• Combined AC and DC power supply
• LED indication for relay status and power supply ON
DMB 01
PMB 01
Product Description
Multi-voltage timer with 7
knob selectable functions
and 7 knob selectable time
ranges within 0.1s and
100h. For mounting on DIN-
rail (DMB01) or Plug-in
(PMB01).
Ordering Key
Housing
Function
Type
Item number
Output
Power supply
DMB 01 C M24
Type Selection
Mounting
DIN-rail
Plug-in
Output
SPDT
DPDT
SPDT
DPDT
Housing
D-Housing
P-Housing
Supply: 24 VDC and 24 to 240 VAC
DMB 01 C M24
DMB 01 D M24
PMB 01 C M24
PMB 01 D M24
Supply: 24 to 240 VAC/DC
Time Specifications
Time ranges
Knob Selectable
0.1 to
to
1
6
to
60 to
0.1 to
1
to
10 to
5%
0.2%
1s
10 s
60 s
600 s
1h
10 h
100h
Output Specifications
Output
Rated insulation voltage
Contact Ratings
(AgSnO
2
)
Resistive loads
AC 1
DC 12
Small inductive loads AC 15
DC 13
Mechanical life
Electrical life
SPDT or DPDT relay
250 VAC (rms)
µ
8 A @ 250 VAC
5 A @ 24 VDC
2.5 A @ 250 VAC
2.5 A @ 24 VDC
30 x 10
6
operations
10
5
operations
(at 8 A, 250 V, cos
ϕ
= 1)
< 7200 operations/h
Setting accuracy
Repeatability
Time variation
Within rated power supply
Within ambient temperature
Reset
Manual reset of time and/or relay
Pulse duration
Power supply interruption
Automatic start
0.05%/V
0.2%/ºC
Close the trigger contact
between pins A1 and Y1
or 2 and 5
100 ms
200 ms
Connect pins A1 and Y1
or 2 and 5
Operating frequency
Dielectric strength
2 kVAC (rms)
Dielectric voltage
Rated impulse withstand volt. 4 kV (1.2/50 µs)
Specifications are subject to change without notice (15.12.05)
1

PMB01DM24 Related Products

PMB01DM24 DMB01CM24 DMB01DM24 PMB01CM24
Description CARLO GAVAZZI - PMB01DM24 - TIME DELAY RELAY; DPDT; 100H; 240VAC/DC CARLO GAVAZZI - PMB01DM24 - TIME DELAY RELAY; DPDT; 100H; 240VAC/DC CARLO GAVAZZI - PMB01DM24 - TIME DELAY RELAY; DPDT; 100H; 240VAC/DC CARLO GAVAZZI - PMB01DM24 - TIME DELAY RELAY; DPDT; 100H; 240VAC/DC
[Mill MYB-YT507 development board trial experience] xfce desktop environment establishment
[i=s]This post was last edited by lugl4313820 on 2022-7-23 17:15[/i]After changing to the Ubuntu system, you can experience the xfce desktop. 1. After connecting to the development board with ssh, log...
lugl4313820 Domestic Chip Exchange
Micropython TurnipBit LCD5110 displays English words
I believe everyone is familiar with the Microbit development board. I have posted some experiments using the Micropython development board before, most of which used the TPYboard development board. To...
loktar MicroPython Open Source section
Is there any way to open Windows CE system files? fopen doesn't seem to work, and even copying in ActiveSync doesn't work.
Is there any way to open WindowsCE system files? fopen seems not to work, and even copying in ActiveSync does not work. I just want to open a file in a WindowsCE windows folder, but now I can't copy i...
ruohanzi Embedded System
at45db641E
Has anyone used dataflash at45db641e? How to write its driver? Or what kind of modifications can be made based on the dataflash at45db642d driver?...
蓦然回首qbb ARM Technology
About the precise delay problem of msp430f149
How to write a more accurate delay subroutine in C program without using timer?...
hjl240 Microcontroller MCU
Possibility of using ZigBee in data acquisition system
[color=#000][font=宋体]1. The number of nodes in the continuous acquisition system is 100-200, the node spacing is 2.5 meters, and the maximum distance from the main control is 250-500 meters[/font][/co...
borisding RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1466  1907  1970  903  2241  30  39  40  19  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号