EEWORLDEEWORLDEEWORLD

Part Number

Search

54122-118-06-2300LF

Description
Board Connector, 12 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle
CategoryThe connector    The connector   
File Size107KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Environmental Compliance
Download Datasheet Parametric View All

54122-118-06-2300LF Overview

Board Connector, 12 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle

54122-118-06-2300LF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompliant
ECCN codeEAR99
body width0.19 inch
subject depth0.906 inch
body length0.6 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU ON NI
Contact completed and terminatedMatte Tin (Sn) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Insulation resistance5000000000 Ω
Insulator colorBLACK
insulator materialTHERMOPLASTIC
JESD-609 codee3
Manufacturer's serial number54122
Plug contact pitch0.1 inch
Match contact row spacing0.1 inch
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.54 mm
Plating thickness30u inch
Rated current (signal)3 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.12 inch
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts12
PDM: Rev:K
STATUS:
Released
Printed: Mar 10, 2011
.
Simple frequency meter design
[i=s] This post was last edited by paulhyde on 2014-9-15 09:30 [/i] I haven't studied hard, and now I'm really worried! Topic: Design of a simple frequency meter Requirements: Can measure frequencies ...
彩虹孤雨 Electronics Design Contest
Sampling of input data at irregular times
I would like to ask how to sample data that is input at an uncertain time. For example, in a serial sequence detector, the first data is manually input one second after reset, the second data is input...
渐渐 FPGA/CPLD
Danniu explains signals and systems and digital signal processing (transferred)
Lesson 1 What is convolution? What is the use of convolution? What is Fourier transform? What is Laplace transform?IntroductionMany of my friends are like me. They majored in electronics engineering. ...
zqjqq88 Integrated technical exchanges
What is OTP?
Reprinted from [url]http://www.sikewei.com/techshow.asp?ciid=18[/url] OTP (One-Time password) OTP attempts to solve some of the problems that users have when choosing strong passwords. Most OTPs opera...
白丁 Integrated technical exchanges
Many students said that analog electronics is difficult to learn.
Many students say that analog electronics is difficult to learn. You may want to go to the library to read textbooks written by other teachers: Professor Tong Shibai of Tsinghua University, Mr. Liang ...
weigaole Analog electronics
LPS22HB Barometric Pressure Sensor
Can you provide the C language driver for LPS22HB pressure sensor? I can buy it with money. Contact number: 15872536578, QQ327209795...
hssjj1211 MEMS sensors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 347  1968  2281  315  172  7  40  46  4  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号