EEWORLDEEWORLDEEWORLD

Part Number

Search

SL2-050-S209/02-95

Description
Board Connector, 50 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle
CategoryThe connector    The connector   
File Size229KB,2 Pages
ManufacturerE-tec Interconnect Ltd.
Environmental Compliance
Download Datasheet Parametric View All

SL2-050-S209/02-95 Overview

Board Connector, 50 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle

SL2-050-S209/02-95 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompliant
ECCN codeEAR99
body width0.2 inch
subject depth0.1 inch
body length2.5 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU
Contact completed and terminatedTin (Sn)
Contact point genderMALE
Contact materialBRASS
contact modeRECTANGULAR
Contact resistance20 mΩ
Contact styleSQ PIN-SKT
Dielectric withstand voltage500VAC V
Insulation resistance1000000000 Ω
Insulator colorBLACK
insulator materialPOLYBUTYLENE TEREPHTHALATE
JESD-609 codee3
Manufacturer's serial numberSL
Plug contact pitch0.1 inch
Match contact row spacing0.1 inch
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.54 mm
Plating thicknessFLASH inch
Rated current (signal)3 A
reliabilityCOMMERCIAL
Terminal length0.201 inch
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts50
No. of Pins
Single
Row
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016
017
018
019
020
021
022
023
024
025
026
027
028
029
030
031
032
033
034
035
036
037
038
039
040
Dual
Row
004
006
008
010
012
014
016
018
020
022
024
026
028
030
032
034
036
038
040
042
044
046
048
050
052
054
056
058
060
062
064
066
068
070
072
074
076
078
080
Triple
Row
009
012
015
018
021
024
027
030
033
036
039
042
045
048
051
054
057
060
063
066
069
072
075
078
081
084
087
090
093
096
099
102
105
108
111
114
117
120
Dimension(mm)
L1
2.54
5.08
7.62
10.16
12.70
15.24
17.78
20.32
22.86
25.40
27.94
30.48
33.02
35.56
38.10
40.64
43.18
45.72
48.26
50.80
53.34
55.88
58.42
60.96
63.50
66.04
68.58
71.12
73.66
76.20
78.74
81.28
83.82
86.36
88.90
91.44
93.98
96.52
99.06
L2
5.08
7.62
10.16
12.70
15.24
17.78
20.32
22.86
25.40
27.94
30.48
33.02
35.56
38.10
40.64
43.18
45.72
48.26
50.80
53.34
55.88
58.42
60.96
63.50
66.04
68.58
71.12
73.66
76.20
78.74
81.28
83.82
86.36
88.90
91.44
93.98
96.52
99.06
101.60
Design of Precision Electronic Weigh Scale Using AD7190 24-bit Σ-Δ ADC with Built-in PGA
The specific plan is still under discussion. Take a seat first. :Laugh:[[i]This post was last edited by deweyled on 2011-6-24 15:36[/i]]...
deweyled ADI Reference Circuit
A Brief Analysis of Smartphone Quad-core Processors
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 20:03[/i]The emergence of smartphones has brought about dramatic changes in people's work, communication and entertainment. Of course, the...
wstt Mobile and portable
Digital tube abnormal display
Why when I download the code to the microcontroller and run it, the digital tubes show something at first, but it is not correct, and finally all eight digital tubes are off... Can you please tell me ...
小瓜子 51mcu
How to use the timer in the stream interface driver under WINCE? There is no window handle in the driver. If I don't set the window handle, it always reports GWES-related Data Abort.
How to use the timer in the stream interface driver under WINCE? There is no window handle in the driver. If I don't set the window handle, it always reports GWES-related Data Abort....
wangmingding Embedded System
This is my first time to engage in embedded development, and I have a basic question: How to send information to several devices connected to one serial port?
The structure is like this: several displays are connected to a serial port through a single-chip microcomputer. Now my main program needs to write information to the serial port to determine which di...
malebanshee Embedded System
FAQ_How to solve the ADC sampling accuracy problem in BlueNRG-12
Author: ST Engineer Weisheng CHEN Click to download the pdf document to view:Keywords: BlueNRG-1/2, ADCProblem: The sampling accuracy of the ADC module of BlueNRG-1/2 is not high enough. Background: W...
nmg ST - Low Power RF

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1258  2098  489  557  1755  26  43  10  12  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号