IP Rating ............................................................ IP 40 .....................................................................IP 40
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Mechanical Characteristics
1
Stop Strength (1/4 ” D shaft) .............................................................................................................................................45.19 N-cm (4 lb.-in.)
(1/8 ” D shaft) .............................................................................................................................................33.89 N-cm (3 lb.-in.)
Starting ........................................................................................................................................... 0.3 max. above average running torque
Running Torque
Single or Dual Section (A & R Bushings) .................................................................................................. 0.21 to 1.06 N-cm (0.3 to 1.5 oz.-in.)
Single or Dual Section (C & U Bushings) .................................................................................................. 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Mounting .............................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Variation ...................................................................................................................... 0.35 N-cm (0.5 oz.-in.) maximum in 45 ° shaft travel
Weight (Single Section, Metal Bushing)...............................................................................................................................12.7 grams nominal
Terminals .................................................................................................................................Printed circuit terminals, J-Hooks or solder lugs
Soldering Condition ...........................................Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ” wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking ..................................................................................Manufacturer’s trademark, date code, resistance, manufacturer’s part number
Ganging (Multiple Section Potentiometers).............................................................................................................................2 cups maximum
Hardware ...................One lockwasher and one mounting nut is shipped with each potentiometer, except where noted in the part number.
NOTE:
1
At
Performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Product Dimensions
Model 91 PC Pin Terminals, In-Line
22.86 ± 0.43
(.900 ± .017)
MOUNTING
SURFACE
12.70 ± .229
(.500 ± .009)
0.79 ± .025
(.031 ± .010)
DIA.
13.72 ± 0.38
(.540 ± .015)
1.37 ± 0.08
(.054 ± .003)
2.36 ± 0.08
(.093 ± .003)
15.88
(.625)
7.92
(.312)
Model 92 J-Hooked
Terminals, In-Line
.79
(.031) 2 PLCS.
3 2 1
SEE
HOW TO ORDER
CHART FOR
BUSHING OPTIONS.
10.16 ± 0.30
(.400 ± .012)
11.05 ± 0.20
(.435 ± .008)
SEE
NEXT PAGE
FOR SHAFT
OPTIONS.
2.54
(.100)
2.54
(.100)
1.19
(.047)
“A” STYLE
A.R. LUG
R
9.53
(.375)
15.29 ± 0.56
(.602 ± .022)
.254
(.010)
GAP
5.08
(.20)
1.52
(.06)
R2
R1
1
2
3
1
2
3
0.76 ± 0.05
(.030 ± .002)
TYP.
Model 94 J-Hooked
Terminals, "L" Pattern
Model 93 PC Pin Terminals, "L" Pattern
22.86 ± 0.43
(.900 ± .017)
MOUNTING
SURFACE
12.70 ± .229
(.500 ± .009)
0.79 ± .025
(.031 ± .010)
DIA.
13.72 ± 0.38
(.540 ± .015)
1.37 ± 0.08
(.054 ± .003)
2.36 ± 0.08
(.093 ± .003)
15.88
(.625)
7.92
(.312)
.81
(.032)
R. MAX.
5.33 ± .76
(.21 ± .03)
3.81
(.150)
MAX. TYP.
1.52
(.06)
GAP
3 2 1
SEE
HOW TO ORDER
CHART FOR
BUSHING OPTIONS.
DIA.
0.81
TYP.
(.032)
10.16 ± 0.30
(.400 ± .012)
R2
R1
5.08 ± 0.38
(.200 ± .015)
11.05 ± 0.20
(.435 ± .008)
SEE
NEXT PAGE
FOR SHAFT
OPTIONS.
1.19
(.047)
“A” STYLE
A.R. LUG
R
9.53
(.375)
12.70 ± 1.02
(.500 ± .040)
Shaft Flat Orientation
2.54
(.100)
2.54
(.100)
1
3
2
1
3
2
0.76 ± 0.05
(.030 ± .002)
TYP.
120 ° ± 5 ° STD.
FLAT ORIENTATION
(SHAFT AT CCW END)
1
CCW
2
POTENTIOMETER
3
Model 95 Solder Lug Terminals, "Triangular" Pattern
My industrial computer is installed with XP system, which needs a watchdog, so my program needs to operate IO, but XP does not allow applications to directly operate IO! What should I do? Please give ...
The DAC12 module of MSP430 can convert the result of operation processing into analog quantity to operate the working process of the controlled object. DA is one of the commonly used devices in the co...
As shown in the attached circuit and parameters, when I_in reaches 1.8V, it cannot coincide with the I_in+ half axis. The average value of the 50hz AC signal and the oscilloscope's measurement functio...
Content: Design requirements and data for the red, green and yellow signal traffic light control circuit design at a crossroads: 1. Use red, green and yellow light-emitting diodes as signal lights. Th...
The one that is not short-circuited is after automatic routing. The one that is short-circuited is after deleting a section of routing and then adding it manually. Why is it short-circuited? {:1_122:}...
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
Dual-mode inverters can operate both in conjunction with the grid and independently. These inverters can inject excess energy from renewable energy and storage devices into the grid, and withdraw p...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
Limited vocabulary recognition
According to the number of characters, words or short sentences in the vocabulary, it can be roughly divided into: less than 100 is small vocabulary; 100-1000 is...[Details]
summary
There are multiple approaches to making industrial systems more intelligent, including applying artificial intelligence (AI) technology at the edge and in the cloud to sensor...[Details]
1 Introduction
In the mid-1960s, American scientist Maas conducted extensive experimental research on the charging process of open-cell batteries and proposed an acceptable charging curve for ...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
Common Mode Semiconductor has officially released its latest generation of power management ICs—the GM6506 series. This fully integrated high-frequency synchronous rectification step-down p...[Details]
With the rapid development of electric vehicles in my country, people are beginning to pay attention to the issue of radiation from electric vehicles. We all know that mobile phones emit radiation,...[Details]
Electric vehicles are now widespread, but they've brought with them a host of problems, the most prominent of which is charging. Small electric vehicles (EVs) are a new form of transportation in a ...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
In the field of intelligent driving, regulations are becoming increasingly stringent, and the technical threshold continues to rise. Especially after the traffic accident in March 2025, the Ministr...[Details]
In daily life, when we purchase a transformer, we are faced with the installation and wiring procedures. Generally speaking, large transformers such as power transformers are equipped with speciali...[Details]
As the range of electric vehicles continues to increase, driving electric vehicles for long-distance travel has become a trend. For high-speed travel, how much impact will high-speed driving of ele...[Details]
introduction
In today's busy society, people experience chronic high stress, which in turn poses a significant threat to our health. Therefore, effectively relieving stress has become a pr...[Details]