EEWORLDEEWORLDEEWORLD

Part Number

Search

2637LHAB33001L380V/6

Description
Rocker Switch, (on)-off-(on), Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2637LHAB33001L380V/6 Overview

Rocker Switch, (on)-off-(on), Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2637LHAB33001L380V/6 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator colorGREEN
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialSILVER
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact function(ON)-OFF-(ON)
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialSILVER
Shell materialPOLYAMIDE
illuminationLAMP
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch actionMOMENTARY
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Softice debugger problem
According to the method in Wu Anhe's "WDM Device Driver Development", in the softice code window, set a breakpoint in the source program. Then exit softice and run the program to be debugged. At this ...
anceyfang Embedded System
About FlashBurn can not burn
SEED-DEC643 User Guide: Before performing video testing, the FPGA programming information must be burned into the FLASH. When testing the video image device, it is forbidden to operate the 0th page of...
fish001 DSP and ARM Processors
I would like to ask CE experts, where are the window messages (messages sent by other processes) received? Why is there no WndProc()?
I would like to ask CE experts, where are the window messages (messages sent by other processes) received? Why is there no WndProc()? It's urgent!...
lijia687 Embedded System
Practical questions about Windows 2000/XP WDM device driver development
The examples in Wu Anhe's "Windows2000/XP WDM Device Driver Development" are based on win2000/DS2.6/win2k ddk. I am using win xp, DS2.6, and after installing xp sp1 ddk, I can still compile and genera...
wonitaluck Embedded System
Switching power supply use
How can I use an existing switching power supply when not in a lab? What should I use to connect the live and neutral wires at the input? Can I use the existing plugs to modify it? I need your advice,...
lusss Test/Measurement
LED transparent screen signal transmission method
LED transparent screens have been widely used in leisure and civilization squares, wealthy business bases, commercial streets, railway stations, subways, shopping malls and other places. Due to the di...
jucaiyuan008 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 970  2884  2586  2310  211  20  59  53  47  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号