EEWORLDEEWORLDEEWORLD

Part Number

Search

AJ921122R3FH

Description
Rocker Switch
CategoryMechanical and electronic products    switch   
File Size546KB,6 Pages
ManufacturerPanasonic
Websitehttp://www.panasonic.co.jp/semicon/e-index.html
Download Datasheet Parametric View All

AJ921122R3FH Overview

Rocker Switch

AJ921122R3FH Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Manufacturer's serial numberAJ9
Switch typeROCKER SWITCH
!
Discontinued as of August 31, 2012
AJ9 (J9)
VDE
POWER ROCKER SWITCH
AJ9 (J9)
SWITCHES
PRECAUTIONS WHEN
USING CADMIUM-FREE
CONTACT TYPE
Models with cadmium-free contacts have
been introduced in order to reduce
environmentally harmful substances. (“F”
is affixed to the end of the part number.)
We ask customers who are currently
using products with cadmium-containing
contacts (no “F” at the end of the part
number) to please make the switch to
models with cadmium-free contacts.
When switching, operating life may differ
depending on the load. Please be sure to
verify this by conducting an evaluation
using actual equipment.
AJ9 switch snap-in mounting type
FEATURES
1. Power rocker switches for safety
requirements.
• All versions comply with ClassII
EN61058-1 insulation grade.
Insulation distance: 8mm Min.
Contact gap: 3mm Min.
¥ International Standard-approved
status
AJ9 switch
Already approved
UL, CSA, VDE, SEMKO
AJ9 switch screw mounting type
2. High inrush current resistance is
ideal for office automation equipment.
Type
AJ9
Inrush
100A
Contact rating
16A 250V AC
Expected
life
Min.10
4
3. Eight standard actuator colors
White, black, red, dark gray, light gray,
blue, green, yellow
RoHS Directive compatibility information
http://www.nais-e.com/
CONSTRUCTION
Actuator
Case
Snap-in Clip
Dustproof construction
Contact gap (more than 3mm)
The EN60950 (intended for office automation
equipment) conforms with a 3mm gap.
When directly opening or closing the primary power
supply side, a contact gap of at least 3mm is required
in order to ensure safety.
147
06/2006
Some experience with VHDL
1. About ports VHDL defines 5 types of ports, namely In, Out, Inout, Buffer and Linkage. Only the first four are used in actual design. The use of In and Out ports is relatively simple. Here, we mainl...
eeleader FPGA/CPLD
Analysis of Magnetoresistor Compensation Circuit
Hello everyone! The attached picture is the temperature compensation circuit of the magnetoresistor. How should R1 and R2 be determined? How should this circuit be analyzed? ? Thank you!...
NICKY99 Analog electronics
In VHDL, what is the difference between behavior and behavioral?
In VHDL, what is the difference between behavior and behavioral? Thanks! ! ! !...
acetuo FPGA/CPLD
Humidity sensor selection
If the humidity sensor is used at different temperatures, its indication must also consider the influence of temperature drift. As we all know, relative humidity is a function of temperature, and temp...
qwqwqw2088 Analogue and Mixed Signal
Newbie reporting in, I have a small question about wiring!!
I learned that it is not possible to route at right angles, but I don't understand why. As shown in the figure, two lines on different routing layers form a right angle through a via. Compared with Fi...
Zed-Tang PCB Design
The problem of Chinese input failure in WinCE5.0
The PDA I bought has WinCE5.0 system and Chinese input method installed. Chinese can be input in WordPad on the PDA. I used VS2005 to develop WinCE5.0 applications. After downloading the application t...
sonofwuyuan Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1498  2878  494  2081  1824  31  58  10  42  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号