EEWORLDEEWORLDEEWORLD

Part Number

Search

RPM0025MP301C207211Z13

Description
Absolute Magnetostrictive Sensor
CategoryThe sensor    Sensor/transducer   
File Size2MB,14 Pages
ManufacturerMTS Sensors
Websitehttps://www.mtssensors.com
Download Datasheet Parametric View All

RPM0025MP301C207211Z13 Overview

Absolute Magnetostrictive Sensor

RPM0025MP301C207211Z13 Parametric

Parameter NameAttribute value
MakerMTS Sensors
Reach Compliance Codeunknow
Other featuresIP 65
Linearity(%)0.01 %
Maximum operating temperature75 °C
Minimum operating temperature-40 °C
resolution5 µm
Sensor/Transducer TypeLINEAR POSITION SENSOR,MAGNETOSTRICTIVE,ABSOLUTE
Maximum supply voltage28.8 V
Minimum supply voltage20.4 V
Termination typeCABLE
Base Number Matches1
Temposonics
®
®
Magnetostrictive, Absolute, Non-contact
Linear-Position Sensors
R-Series Models RP and RH
CANbus Outputs (CANopen/CANbasic)
Data Sheet
SENS
O
RS
Document Part Number
550991 Revision D
Model RP Profile-style position sensor
FEATURES
Linear, Absolute Measurement
LEDs For Sensor Diagnostics
Superior Accuracy, Resolution down to 2 μm
Non-Contact Sensing Technology
Linearity Deviation Less Than 0.01%
Repeatability Within 0.001%
Direct CAN Output (Position + Velocity)
Model RH Rod-style position sensor
Time-based Magnetostrictive position sensing principle
Movable position magnet
Magnetic field encompasses
entire waveguide - generated
by the interrogation pulse
Interrogation
Return wire
Waveguide
Strain-Pulse detector
Bias magnet
Magnetic field from
position magnet
Interaction of magnetic
fields causes waveguide to
generate a strain pulse
BENEFITS
Rugged Industrial Sensor
Selectable Bus Termination (CANopen)
CANopen with Heartbeat Function
APPLICATIONS
Continuous Operation In Harsh Industrial Conditions
High Pressure Conditions
For Accurate, Multi-Magnet Position Measurement
(up to 20 positions per sensor)
TYPICAL INDUSTRIES
Factory Automation
Fluid Power
Plastic Injection and Blow Molding
Material Handling and Packaging
Benefits of Magnetostriction
Temposonics linear-position sensors use the time-based
magnetostrictive position sensing principle developed by MTS.
Within the sensing element, a sonic-strain pulse is induced in a
specially designed magnetostrictive waveguide by the momentary
interaction of two magnetic fields. One field comes from a moveable
permanent magnet that passes along the outside of the sensor. The
other field comes from an “interrogation” current pulse applied along
the waveguide. The resulting strain pulse travels at sonic speed along
the waveguide and is detected at the head of the sensing element.
The position of the magnet is determined with high precision and
speed by accurately measuring the elapsed time between the applica-
tion of the interrogation pulse and the arrival of the resulting strain
pulse with a high-speed counter. The elapsed time measurement is
directly proportional to the position of the permanent magnet and is
an absolute value. Therefore, the sensor's output signal corresponds
to absolute position, instead of incremental, and never requires
recalibration or re-homing after a power loss. Absolute, non-contact
sensing eliminates wear, and guarantees the best durability and
output repeatability.
All specifications are subject to change. Contact MTS for specifications and
engineering drawings that are critical to your application. Drawings contained
in this document are for reference only. Go to http://www.mtssensors.com for
the latest support documentation and related media.
Is there a pressure sensor with 1 gram accuracy?
[i=s]This post was last edited by hahadiy on 2015-3-30 15:18[/i] I have never used a pressure sensor before. I want to make a small thing recently. I wonder if there is a pressure sensor with an accur...
hahadiy Microcontroller MCU
Linux was not installed and the hard drive was gone.
There are two hard disks. I plan to install Linux on the last partition of the second hard disk (Primary Slave). (This idea doesn't seem to be right either.) After I customized the Linux partitions, w...
maojunwei123 Linux and Android
Share the port functions and settings of msp430f149
The commonly used ports of MSP430f149 are P1, P2, P3, P4, P5, and P6, which can be used directly for input/output. There are no special input/output instructions in the MSP430 system, and input/output...
fish001 Microcontroller MCU
The topology diagram of the safe city system is really informative!
[[i] This post was last edited by clark on 2009-12-23 10:02[/i]]...
clark Industrial Control Electronics
When you develop an embedded Linux program, after debugging and realizing the functions, do you still test it?
From EEWORLD cooperation group: arm linux fpga embedded 0 (49900581) Group leader: wangkj How do you test it in general? Is there any testing tool? Thank you for letting me know, thank you for partici...
梦之路 Test/Measurement
Analysis of capacitor voltage-drop circuit
[table] [tr][td][color=rgb(51, 51, 51)][size=14px][align=left]The conventional method of converting AC mains power into low-voltage DC is to use a transformer to reduce the voltage and then rectify an...
wstt Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1595  2730  432  1203  1288  33  55  9  25  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号