VRLA Rechargeable Battery
BP10-12
FEATURES
Maintenance free(no water topping-up required).
No free acid(Non-spillable battery).
Low self-discharge rate, lower than 3% capacity loss per month.
Can be used in any orientation(excluding used inverted).
Absorbent Glass Mat technology for efficient gas recombination.
Measures
Technology
Values
Innovation
APPLICATION
UPS
Laboratory
Equipment
SPECIFICATIONS
Nominal Voltage
Nominal Capacity
Approx. Weight
Terminals
Internal Resistance
Max. Discharge Current
Max. Charge Current
Operating Temperature Range
12 V
10.0Ah @ 20 hour rate F.V.(1.75V/cell)
3300g(7.28lbs.)
T2 (Faston Tab 250) T1 is optional
(Fully Charged )
17m
150 A (5 sec.)
3.0 A
Charge 0
o
C~40
o
C(32
o
F~104
o
F)
Discharge -20
o
C~50
o
C(-4
o
F~122
o
F)
Storage. -20
o
C~40
o
C(-4
o
F~104
o
F)
Standard: ABS( UL 94-HB) BP10-12
Optional: Flame Retardant ABS(UL 94-V0) BP10-12FR
Container Material
DIMENSION(mm/inch)
Length
151±1.5
(5.94±0.06)
Width
65±1.5
(2.56±0.06)
116 2(4.57 0.08)
IEC 61056-1
JIS C 8702-1
GB/T 19639.1
OUTER DIMENSIONS
TERMINAL TYPE
Terminal T1
3.2(0.13)
Terminal T2
3.4(0.13)
4.75(0.19)
151 1.5(5.94 0.06)
112 1.5(4.41 0.06)
65 1.5(2.56 0.06)
Container Height
112±1.5
(4.41±0.06)
Total Height
116±2.0
(4.57±0.08)
6.35(0.25)
0.8(0.03)
Constant power discharge characteristics at 25
o
C/77
o
F
F.V.
(V/cell)
Discharge
Time
Unit: W
3 Hr
29.15
29.73
30.00
30.21
30.39
5 Min
361.6
418.5
444.6
464.6
480.0
10 Min
266.2
288.4
298.7
305.9
312.0
15 Min
213.3
223.1
230.0
235.3
240.0
30 Min
126.9
131.7
134.7
136.6
138.0
o
1 Hr
72.78
74.96
76.31
77.23
78.00
o
5 Hr
20.10
20.40
20.51
20.58
20.64
10 Hr
11.23
11.40
11.46
11.49
11.49
20 Hr
5.91
6.00
6.04
6.05
6.05
1.80V
1.75V
1.70V
1.65V
1.60V
Discharge
Time
Constant current discharge characteristics at 25 C/77 F
F.V.
(V/cell)
Unit: A
3 Hr
2.43
2.48
2.50
2.52
2.53
5 Min
32.57
38.39
40.79
42.62
44.04
10 Min
23.43
25.38
26.30
26.93
27.46
15 Min
18.55
19.40
20.00
20.46
20.87
30 Min
10.75
11.16
11.42
11.58
11.69
1 Hr
6.12
6.30
6.41
6.49
6.55
5 Hr
1.675
1.700
1.709
1.715
1.720
10 Hr
0.936
0.950
0.955
0.958
0.958
20 Hr
0.493
0.500
0.503
0.504
0.504
1.80V
1.75V
1.70V
1.65V
1.60V
A/3
REV. Mar. 2013
All data and artworks shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
Powered by
B.B. Battery Co., Ltd.
0.8(0.03)
7.95(0.31)