The EN60950 (intended for office automation equipment)
conforms with a 3mm
.118inch
gap.
When directly opening or closing the primary power supply side,
a contact gap of at least 3mm
.118inch
is required in order to
ensure safety.
19
J8(AJ8)
ORDERING INFORMATION
Ex.
AJ8
W
1
0
0
W
W
T
Type of
Size of handle
switch
AJ7: J8
Nil: Standard size
switch
(10 mm
.394inch)
W: Wide size
(19 mm
.748 inch)
Poles
Terminal shape
Actuator indication
0:
1:
2:
O
I
Actuator color*
W: White
B: Black
R: Red
Z: Dark gray
H: Light gray
L: Blue
G: Green
Y: Yellow
Flang color*
Nil: Black
(W: White)
(R: Red)
(Z: Dark gray)
(H: Light gray)
(L: Blue)
(G: Green)
(Y: Yellow)
Insulation guard
Nil: Short guard
type
T: Long guard
type (.250
Quick-connect
terminal and
soldering
terminal of
standard size
only)
1: Single pole 0: .250 Quick-
2: Double pole
connect terminal
1: Soldering
terminal
2: PC board
terminal
3: PC board right
andle terminal
4: PC board left
angle terminal
O
I
Remarks: 1. Please consult us for details concerning different flange colors.
2. “I
O”
is engraved on all flanges.
3. The color of
I O
indication on the actuator:
• White actuator: black
• Others: white
PRODUCT TYPES
1. Standard actuator type
(1) Without indication on actuators
Terminal shape
.250 Quick-connect terminal
Soldering terminal
PC board terminal
PC board right angle terminal
PC board left angle terminal
Poles
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Poles
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
ON-OFF
Operating types
With
| O
indication
AJ8101*
AJ8201*
AJ8111*
AJ8211*
AJ8121*
AJ8221*
AJ8131*
AJ8231*
AJ8141*
AJ8241*
ON-OFF
Operating types
Without indication
AJ8100*
AJ8200*
AJ8110*
AJ8210*
AJ8120*
AJ8220*
AJ8130*
AJ8230*
AJ8140*
AJ8240*
With
— O
indication
AJ8102*
AJ8202*
AJ8112*
AJ8212*
AJ8122*
AJ8222*
AJ8132*
AJ8232*
AJ8142*
AJ8242*
(2) With
| O
indication on actuators
Terminal shape
.250 Quick-connect terminal
Soldering terminal
PC board terminal
PC board right angle terminal
PC board left angle terminal
(Standard flange color is black. For other colors type, they are custom ordered.)
Remarks: 1. A letter indicating the actuator color is entered in place of * symbol. (W: White B: Black R: Red Z: Dark gray H: Light gray L: Blue G: Green
Y: Yellow)
For requests of other flange color,please suffix following letter. (W: White R: Red Z: Dark gray H: Light gray L: Blue G: Green Y: Yellow)
2. Long guard type is available for .250 Quick-connect terminal and soldering terminal type.
When ordering, please suffix T.
3. The color of
| O
indication on the actuator:
White actuator: black Others: white
4. They come with a stamp indicating international standards without your request.
5. Note that the position of the
|
mark on the flange is used as a reference for left angle and right angle units as shown in the diagram below.
I
mark
I
mark
Right angle terminal
Left angle terminal
20
J8(AJ8)
2.Wide actuator type
(1) Without indication on actuators
Terminal shape
.250 Quick-connect terminal
Soldering terminal
PC board terminal
Poles
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
Poles
Single pole
Double pole
Single pole
Double pole
Single pole
Double pole
ON-OFF
Operating types
ON-OFF
Operating types
Without indication
AJ8W100*
AJ8W200*
AJ8W110*
AJ8W210*
AJ8W120*
AJ8W220*
With
| O
indication
AJ8W101*
AJ8W201*
AJ8W111*
AJ8W211*
AJ8W121*
AJ8W221*
With
— O
indication
AJ8W102*
AJ8W202*
AJ8W112*
AJ8W212*
AJ8W122*
AJ8W222*
(2) With
| O
indication on actuators
Terminal shape
.250 Quick-connect terminal
Soldering terminal
PC board terminal
(Standard flange color is black. For other colors type, they are custom ordered.)
Remarks: 1. A letter indicating the actuator color is entered in place of * symbol. (W: White B: Black R: Red Z: Dark gray H: Light gray L: Blue G: Green
Y: Yellow)
For requests of other flange color,please suffix following letter. (W: White R: Red Z: Dark gray H: Light gray L: Blue G: Green Y: Yellow)
2. The color of
| O
indication on the actuator:
White actuator: black Others: white
3. They come with a stamp indicating international standards without your request.
SPECIFICATIONS
1. Contact rating
Type
J8 switch
Voltage
AC 250V
Resistive load
(cos
φ
]
1.0)
16A
Motor load
(EN61058-1)
(cos
φ
]
0.6)
4A
Remark: The motor load is in accordance with EN61058-1. Inlush current can be switched up to the value of 6 times the indicated rating.
2. Characteristics
Expected life
(Min. operations)
Initial insulation resistance
(Between terminals)
Initial breakdown voltage
(Between terminals)
Initial contact resistance
(By voltage drop at 1A, 2 to 4V DC)
Temperature rise
Vibration resistance
Shock resistance
Actuator strength
Tensile terminal strength
Ambient temperature
Ambient humidity
Flame retardancy
Tracking resistance
Operating force
(reference characteristics)
Single pole
Double pole
at 6
×
10
3
ope. or less
from 6
×
10
3
ope. to 10
4
Mechanical
Electrical
Min. 5
×
10
4
(at 20 cpm.)
Min. 10
4
(at 7 cpm., at rated load)
Min. 100 MΩ
(at 500V DC measured by insulation resistive meter)
2,000 Vrms detection current: 10 mA
Max. 100mΩ
Max. 30°C (UL1054)
Max. 55°C (VDE0630)
10 to 55 Hz at double amplitude of 1.5mm
Min. 490m/s
2
{50 G}
40 N {4.08kgf} for 1 minute
(operating direction)
100 N {10.2kgf} for 1 minute or more
(Pull & push direction)
–25°C to +85°C
– 13
°
F to +185
°
F
(Not freezing below 0°C
32
°
F
)
Max. 85%R.H.
UL94V-0
Min. 175
2.45
±
1.47N {0.25
±0.15kgf}
4.5
±
2.5N {0.46
±0.25kgf}
Remark: Test conditions are in accordance with EN61058-1, UL1054 and JIS C 6571.
21
J8(AJ8)
DIMENSIONS
1) .250 Quick-connect terminal/Short guard type
Long guard type
.250 Quick-connect terminal
Double pole
15
.591
12.8
.504
10
.394
7.7
.303
ON
OFF
mm
inch
General tolerance
±0.5
±.020
Diagram of recommended
locations for panel
mounting holes
X
32 deg
7.7
.303
ON
OFF
−0
12.9
+0.1
−0
.508
+.004
±4
Single pole
30
1.181
30
1.181
32 deg
±4
2
.079
16
.630
4.4
.173
10.6 11
.417 .433
19.5
.768
2
.079
16
.630
4.4
.173
10.6
.417
Panel thickness
0.75 to 1.25
.030 to .049
1.25 to 2
.049 to .079
2 to 3
.079 to .118
X
28.2
+0
–0.1
1.110
+0
–.004
28.4
+0
–0.1
1.118
+0
–.004
28.8
+0
–0.1
1.134
+0
–.004
φ
1.75
φ
.069
15
.591
28
1.102
6.35
.250
φ
1.75
φ
.069
15
.591
28
1.102
6.35
.250
8.75
.344
12.5
.492
0.8
.031
4.375
.172
2) Soldering terminal
Long guard type
Soldering terminal
Double pole
15
.591
12.8
.504
10
.394
7.7
.303
ON
OFF
Single pole
30
1.181
32
±4
deg
7.7
.303
ON
OFF
Diagram of recommended
locations for panel
mounting holes
X
30
1.181
32
±4
deg
2
.079
16
.630
−0
12.9
+0.1
−0
.508
+.004
19.5
.768
2
.079
16
.630
2.5
.098
15
.591
28
1.102
4.375
.172
3.5
.138
10.6 11
.417 .433
Panel thickness
0.75 to 1.25
.030 to .049
1.25 to 2
.049 to .079
2 to 3
.079 to .118
X
28.2
+0
–0.1
1.110
+0
–.004
28.4
+0
–0.1
1.118
+0
–.004
28.8
+0
–0.1
1.134
+0
–.004
10.6
.417
2.5
.098
15
.591
28
1.102
3.5
.138
8.75
.344
12.5
.492
0.8
.031
3) PC board terminal
Double pole
15
.591
±.004
3
±0.2
.118
±.008
±0.1
PC board pattern
Single pole
1.2
±0.1
.047
±.004
8.75
±0.1
.344
±.004
15
.591
±.004
3
±0.2
.118
±.008
±0.1
Diagram of recommended locations for
panel mounting holes
X
1.2
±0.1
.047
±.004
4.375
±0.1
.172
±.004
−0
12.9
+0.1
−0
.508
+.004
Double pole
15
.591
12.8
.504
10
.394
7.7
.303
ON
OFF
Single pole
30
1.181
32
±4
deg
19.5
.768
2
.079
16
.630
(7.5)
(.295)
2
.079
15
.591
28
1.102
4
.157
8.75
.344
12.5
.492
0.8
.031
4.375
.172
Panel thickness
0.75 to 1.25
.030 to .049
1.25 to 2
.049 to .079
2 to 3
.079 to .118
X
28.2
+0
–0.1
1.110
+0
–.004
28.4
+0
–0.1
1.118
+0
–.004
28.8
+0
–0.1
1.134
+0
–.004
22
J8(AJ8)
4) PC board right angle terminal
PC board pattern
Double pole
15
±0.1
.591
±.004
3
±0.2
.118
±.008
1.2
±0.1
.047
±.004
8
±0.1
.315
±.004
mm
inch
General tolerance
±0.5
±.020
Diagram of recommended locations for
panel mounting holes
X
15
±0.1
.591
±.004
3
±0.2
.118
±.008
1.2
±0.1
.047
±.004
21.0
±0.3
.827
±.012
−0
12.9
+0.1
17.5
±0.3
−0
.508
+.004
.689
±.012
Single pole
Terminal side
4.375
.172
±.004
±0.1
Double pole
30
1.181
32°
±4
7.7
.303
ON
OFF
Single pole
15
.591
12.8
.504
10
.394
19.5
.768
2
.079
16
.630
Panel thickness
2
.079
X
28.2
+0
–0.1
1.110
+0
–.004
28.4
+0
–0.1
1.118
+0
–.004
28.8
+0
–0.1
1.134
+0
–.004
0.75 to 1.25
.030 to .049
1.25 to 2
.049 to .079
12.5
.492
8 0.8
.315 .031
28
1.102
4
.157
2 to 3
.079 to .118
Remark: Left angle terminals type is also available.
FIG1 shows the composition of the LIV test system, which includes a 2602 source meter, a 2510-AT automatic temperature control source meter, and a computer equipped with a GPIB interface board.
The Mo...
Problem: When the 51 MCU communicates with the computer software, the number is lost when the communication is more than 100 or more than 200 times. Original post address: [url=https://bbs.eeworld.com...
[color=Black] Texas Instruments (TI) and 4DSP, a professional innovator of low-power, lightweight, small FPGA signal image processing systems, announced the joint development of the latest integrated ...
introduction
The automobile control system controls various performances of the automobile. Due to various reasons, buses always repeat the process of acceleration-deceleration or parking-reaccelera...
High efficiency and low standby power consumption are two major challenges in today's switching power supply design. Resonant topology or LLC topology is becoming increasingly popular because it ca...[Details]
Hardware designers have begun to adopt FPGA technology in high-performance DSP designs because it can provide 10-100 times faster computing than PC-based or microcontroller-based solutions. Previou...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
With the development and widespread application of computer technology, especially in the field of industrial control, computer communication is particularly important. Although serial communication g...[Details]
Editor's note: In order to help technicians or engineers who have knowledge of PIC microcontroller assembly language quickly master the method of using C language to program PIC microcontrollers, t...[Details]
1. System Structure
This system is a simulation system of indoor air-conditioning temperature/humidity control system. The data acquisition and control center collects temperature/humidity...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
LED guardrail lights use fluorescent tubes or LEDs as light sources and continuous guardrails as carriers to form an approximately linear guardrail light strip. This article mainly introduces...[Details]
Only a small number of LED manufacturers can produce high-quality LEDs. For applications that are only used for simple indication, low-quality LEDs are sufficient. However, high-quality LEDs must...[Details]
The rectified DC voltage is then converted back to AC using power electronics such as insulated gate bipolar transistors.
The output voltage is switched on and off at a high frequency, control...[Details]
1. Introduction
With the increasing popularity of fully automatic washing machines, consumers have higher and higher requirements for their environmenta...[Details]
Against the backdrop of global warming, energy conservation and emission reduction have become a global hotspot and focus, which has also sounded the clarion call for the take-off of the LED lighti...[Details]
store
To prevent moisture, LEDs should be stored in a dry and ventilated environment with a storage temperature of -40°C to +100°C and a relative humidity below 85%.
The LED should be use...[Details]