IP Rating ............................................................ IP 40 .....................................................................IP 40
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Mechanical Characteristics
1
Stop Strength (1/4 ” D shaft) .............................................................................................................................................45.19 N-cm (4 lb.-in.)
(1/8 ” D shaft) .............................................................................................................................................33.89 N-cm (3 lb.-in.)
Starting ........................................................................................................................................... 0.3 max. above average running torque
Running Torque
Single or Dual Section (A & R Bushings) .................................................................................................. 0.21 to 1.06 N-cm (0.3 to 1.5 oz.-in.)
Single or Dual Section (C & U Bushings) .................................................................................................. 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Mounting .............................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Variation ...................................................................................................................... 0.35 N-cm (0.5 oz.-in.) maximum in 45 ° shaft travel
Weight (Single Section, Metal Bushing)...............................................................................................................................12.7 grams nominal
Terminals .................................................................................................................................Printed circuit terminals, J-Hooks or solder lugs
Soldering Condition ...........................................Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ” wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking ..................................................................................Manufacturer’s trademark, date code, resistance, manufacturer’s part number
Ganging (Multiple Section Potentiometers).............................................................................................................................2 cups maximum
Hardware ...................One lockwasher and one mounting nut is shipped with each potentiometer, except where noted in the part number.
NOTE:
1
At
Performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Product Dimensions
Model 91 PC Pin Terminals, In-Line
22.86 ± 0.43
(.900 ± .017)
MOUNTING
SURFACE
L
12.70 ± .229
(.500 ± .009)
0.79 ± .025
(.031 ± .010)
DIA.
13.72 ± 0.38
(.540 ± .015)
1.37 ± 0.08
(.054 ± .003)
2.36 ± 0.08
(.093 ± .003)
15.88
(.625)
7.92
(.312)
Model 92 J-Hooked
Terminals, In-Line
.79
(.031) 2 PLCS.
3 2 1
.254
(.010)
GAP
SEE
HOW TO ORDER
CHART FOR
BUSHING OPTIONS.
10.16 ± 0.30
(.400 ± .012)
11.05 ± 0.20
(.435 ± .008)
SEE
NEXT PAGE
FOR SHAFT
OPTIONS.
1.19
(.047)
“A” STYLE
A.R. LUG
R
9.53
(.375)
15.29 ± 0.56
(.602 ± .022)
5.08
(.20)
1.52
(.06)
R2
R1
1
2
3
1
2
3
2.54
(.100)
2.54
(.100)
Model 94 J-Hooked
Terminals, "L" Pattern
0.76 ± 0.05
(.030 ± .002)
TYP.
Model 93 PC Pin Terminals, "L" Pattern
22.86 ± 0.43
(.900 ± .017)
MOUNTING
SURFACE
L
12.70 ± .229
(.500 ± .009)
0.79 ± .025
(.031 ± .010)
DIA.
13.72 ± 0.38
(.540 ± .015)
1.37 ± 0.08
(.054 ± .003)
2.36 ± 0.08
(.093 ± .003)
15.88
(.625)
7.92
(.312)
3 2 1
1.52
(.06)
GAP
.81
(.032)
R. MAX.
5.33 ± .76
(.21 ± .03)
3.81
(.150)
MAX. TYP.
SEE
HOW TO ORDER
CHART FOR
BUSHING OPTIONS.
DIA.
0.81
TYP.
(.032)
10.16 ± 0.30
(.400 ± .012)
R2
R1
5.08 ± 0.38
(.200 ± .015)
11.05 ± 0.20
(.435 ± .008)
SEE
NEXT PAGE
FOR SHAFT
OPTIONS.
1.19
(.047)
“A” STYLE
A.R. LUG
R
9.53
(.375)
12.7 ± 1.02
(.500 ± .040)
Shaft Flat Orientation
2.54
(.100)
2.54
(.100)
120 ° ± 5 ° STD.
FLAT ORIENTATION
(SHAFT AT CCW END)
1
3
2
1
3
2
0.76 ± 0.05
(.030 ± .002)
TYP.
1
CCW
2
POTENTIOMETER
3
Model 95 Solder Lug Terminals, "Triangular" Pattern
When using the smallest board stm32f103vet and using jlink connect, it always prompts count not find supported cpu core on jtag chain bad jtag. . . . Now the program is running, what is the problem? ?...
PIC Development Tools - EasyPIC6 Development System EasyPIC6 is a development system that supports more than 160 8-, 14-, 18-, 20-, 28- and 40-pin PIC microcontrollers.A high-speed on-board USB 2.0 pr...
I used AD13 to draw the board and generate a BOM table in PDF format, and found that the generated table contained fewer materials.See the picture:There are three missing.
1M, 0 ohm, and 1K resistors ...
Time flies~ It's time for our weekly review, so let's not waste time. Let's take a look at what wonderful posts are out! ! [color=Red][b][size=5]Wonderful Posts[/size][/b][/color] [b][url=https://bbs....
Recently, a project used STM32, which required it to sleep at night and wake up at regular time in the morning. I encountered some problems in the process of adjusting RTC. I will share them with you ...
How can I get 1M frequency pulse on pure IO port when I use 4M main frequency?If the system frequency is 4M, how long does it take for a general instruction?...
SinoWise's SH66xx series 4-bit microcontrollers have the characteristics of fast speed, low power consumption, simple structure, easy to use, and high cost performance. They are widely used in remo...[Details]
introduction
Oxygen is an important substance for human metabolism. Brain tissue has a high metabolic rate and consumes about 20% of the total oxygen in the body. In the clinical rescue and ...[Details]
Microelectromechanical systems (MEMS) are gradually entering the consumer, industrial, medical, automotive and computer application markets. Moreover, we cannot ignore their steady progress in the ins...[Details]
At present, the global medical electronics industry is gradually showing attractive development prospects, and the speed of product replacement is constantly increasing. At the same time, due to the p...[Details]
This article discusses how to use an ultra-low-power RF transceiver chip from Zarlink Semiconductor for pacemakers, neurostimulators, drug pumps, and other such implantable medical devices t...[Details]
Introduction: Design of automated test systems
Challenges
To ensure the quality and reliability of products delivered to customers, test managers and engineers use automated test system...[Details]
In the development of high-stability lasers, real-time monitoring of the working state of the laser is an issue that needs to be focused on. This system realizes the high-stability laser temperatur...[Details]
Adding "intelligence" to measurement systems is becoming more common as 8-bit microcontrollers are inexpensive, widely available, and can be programmed using today's common high-level languages, su...[Details]
As microcontrollers become less expensive and more powerful, electrical designers are finding it more cost-effective to use multiple small controllers in both single-board and multi-board systems. ...[Details]
Broadband services supporting triple play voice, video and data are evolving for first mile customers (small businesses and homes). A key factor in this FTTx evolution is GPON (Gigabit Passive Opti...[Details]
MOSFETs are widely used as power switching elements in regulators and motor controllers. They are available as discrete devices or integrated into ICs in various H-bridge configurations.
A hig...[Details]
This article will discuss a common problem in wireless mobile data reception.
Problems facing RF receivers
The common problem faced by RF receivers is that the same hardware must be used ...[Details]
Fetal monitoring is an important means to ensure the safety of perinatal mothers and fetuses and achieve eugenics. Intelligent fetal monitoring is a monitoring method that analyzes the health stat...[Details]
AD604 is a product of Analog Devices (AD). Compared with similar products, AD604 has the characteristics of ultra-low noise, high precision, continuously adjustable gain, and the decibel (dB...[Details]
0Introduction
As a service robot in the field of medical care, the application of smart wheelchairs makes extensive use of mobile robot technology. The key technologies involved in the researc...[Details]