2649LPCE16001L110V/6

Description
Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2649LPCE16001L110V/6 Overview

Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2649LPCE16001L110V/6 Parametric

Parameter NameAttribute value
Objectid313168057
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator colorRED
Actuator length0.394 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialCOPPER
Center contact platingSILVER
Contact (AC) maximum rated power R load0.16HP@250VAC
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact functionON-OFF-ON
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialCOPPER
End contact platingSILVER
Shell materialPOLYAMIDE
illuminationLAMP
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Why can the MPU6050 serial port sometimes read but sometimes not?
Why does the MPU6050 gyroscope sometimes read and sometimes not read? Can anyone help me solve this problem?...
angel1234567 Electronics Design Contest
About PCB layout rules for PCI cards
Feeling good, reposted here, just to spread more knowledge!    PCI card wiring is more particular, which is determined by the characteristics of PCI signals . In conventional high-frequency digital ci...
suifeng654456 FPGA/CPLD
Thank you EEworld, thank you chunyang
I went to Chunyang moderator's home to do some shopping at the weekend to attract everyone's attention. I bought so many books, and I'll keep them for collection. Our childhood in those years Some too...
suoma Suggestions & Announcements
【R7F0C809】==The first program
[i=s]This post was last edited by youyou_123 on 2015-8-13 21:38[/i] The first step is to install the development platform. The second step is to install the R7F0C806-809 MCU device file. [/color] [col...
youyou_123 Renesas Electronics MCUs
There are several tasks in the vxWorks system, and one of them hangs (SUSPEND) during execution. What are the possible reasons?
As the title says. I have never used this system before, so I don't know how it uses memory... ---------- Confused: How can a task crash itself during execution? There is no access protection between ...
iaw2005 Real-time operating system RTOS
Are you following Vishay Technology’s official WeChat account?
[p=null, 2, left][size=3][color=#000000]Did you know that Vishay Technologies, which we are familiar with, has opened an official WeChat account? [/color][/size][/p][p=null, 2, left][size=3][color=#00...
eric_wang Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2279  1712  2245  2311  47  46  35  47  1  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号