EEWORLDEEWORLDEEWORLD

Part Number

Search

2641LPAB1900L220V3

Description
Rocker Switch, On-off, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2641LPAB1900L220V3 Overview

Rocker Switch, On-off, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2641LPAB1900L220V3 Parametric

Parameter NameAttribute value
Objectid312987137
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator colorORANGE
Actuator length0.394 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
Other features220VAC FLUORESCENT LAMP
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialSILVER
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@24VDC
Contact functionON-OFF
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Design of vhdl digital clock
1. System design requirements Assume that the external input pulse is 1 Hz. It is required to design a digital clock with adjustable time using this frequency and capable of displaying hours, minutes ...
Aguilera DSP and ARM Processors
Mouser first experience + a few small questions
[size=4]I got to use the sharp 96 screen in the previous competition. This time I can take advantage of the forum activity to buy one [/size]:lol:lol [size=4]. The main reason is that there is no low-...
数码小叶 Talking
Some alternative issues of MSP430 series (Part 2)
4. F1611 large array definition, can not run normally [align=left] F1611, this RAM is big MSP, haha. Then you may encounter the phenomenon that the MSP program cannot run normally when the variables/a...
qinkaiabc Microcontroller MCU
I already have a .mms file. How can I send it through the GPRS module?
I read some articles online and found the software nowsms. I have generated a .MMS file, which is the PDU of MMS. After uploading it to the mobile phone, it can be sent out through the mobile phone. S...
leijun203 Embedded System
What is the difference between variable frequency air conditioner and fixed frequency air conditioner?
The difference between inverter air conditioners and fixed-frequency air conditioners. As two ways of air conditioning, inverter air conditioners and fixed-frequency air conditioners have great differ...
张中立2013 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1722  1305  1485  2527  2181  35  27  30  51  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号