Tripp Lite's INTERNETOFFICE700 standby UPS system offers surge suppression and long-lasting battery support for personal computers, internetworking
equipment and other sensitive electronics. Internal UPS circuits support entry-level PC systems for up to 45 minutes during power failures and brownouts so
that connected equipment can be shut down without data loss. Offers complete desktop power protection in an attractive gray tower configuration. Includes 3
battery-supported outlets for computer, monitor and one vital system peripheral, plus 3 additional surge suppression-only outlets for printers and other system
accessories not requiring battery support. HID-compliant USB port enables optional unattended system shutdown without data loss in the case of extended
power failure; USB cable included. HID compliant USB port enables integration with built-in power management and auto shutdown features of Windows and
Mac OS X. PowerAlert software available via FREE download from es.tripplite.com. Built-in RJ45 TEL/Ethernet suppression jacks protect modem, fax machine,
cordless phone or other peripheral with a standard single-line tel/DSL or data line connection. Built-in audible alarm and 3 front panel LEDs indicate line power
status, battery power status and battery low/replace status. 700VA/425W power handling ability supports entry-level PCs, network workstations, point-of-sale
equipment, small business phone systems, audio/video equipment and home theater systems. Offers 3.9 min. battery runtime with a full load of 700VA and
11.2 min. with a half load of 350VA. Supports user battery replacement via built-in access panel. $150,000 connected equipment insurance (USA and Canada
Only).
Features
INTERNETOFFICE700 standby UPS system offers UPS battery support, plus complete AC and tel/Ethernet line surge suppression
Supports entry-level PC systems for up to 45 min. during brownouts and power failures to enable a safe system shutdown
Supports a max load of 700VA/425W for 3.9 min.
Supports a half load of 350VA/215W for 11.2 min.
Supplies battery-derived AC output during brownouts starting at 99V, user adjustment allows fine tuning of brownout response to any setting from 83V to
99V
Attractive gray tower configuration
Includes 3 battery-supported outlets plus 3 additional surge suppression-only outlets, and 6-ft. AC line cord (all NEMA 5-15)
HID-compliant USB port enables unattended shutdown without data loss during extended power failures; includes USB cable
HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
USB interface supports timed inverter shutoff after unattended shutdown
PowerAlert software available via FREE download from es.tripplite.com
1/5
PowerAlert software available via FREE download from es.tripplite.com
Supports Tripp Lite's WatchDog software application to restore unresponsive programs by automatically restarting them, and rebooting completely locked
computers by automatically switching UPS power off and back on again
Built-in phone/Ethernet suppression jacks protect modem, fax machine or other peripheral with a dialup,DSL, or data line connection
Built-in audible alarm and 3 front panel LEDs indicate line power, battery power and battery low/replace status
700VA/425W power handling ability supports a variety of computer, internetworking, telecom and consumer electronics equipment
Supports hot-swap battery replacement via built-in access panel
Optional PDUB15 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
Compatible with 120V/60Hz applications for USA, Canada, Mexico and more
$150,000 connected equipment insurance (USA and Canada Only)
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
Output Watt Capacity (Watts)
Nominal Output Voltage(s)
Supported
Frequency Compatibility
Output Voltage Regulation (Battery
Mode)
UPS Output Receptacles
UPS Output Receptacles (Surge
Suppression Only)
Hot-Swap PDU options
Output AC Waveform (AC Mode)
Output AC Waveform (Battery Mode)
700
425
115V; 120V
60 Hz
115V (+/- 5%)
6 5-15R outlet(s)
3 UPS outlets, 3 surge-only outlets
PDUB15 (2U / 8 5-15R outlets)
Sine wave
PWM sine wave
INPUT
Rated input current (Maximum Load)
Nominal Input Voltage(s) Supported
UPS Input Connection Type
UPS Input Cord Length (ft.)
UPS Input Cord Length (m)
Recommended Electrical Service
Input Phase
12A
120V AC
5-15P
6
1.8
15A 120V
Single-Phase
BATTERY
Full Load Runtime (min.)
3.9 min. (425w)
2/5
Half Load Runtime (min.)
DC System Voltage (VDC)
Internal UPS Replacement Battery
Cartridge
Battery Access
Battery Replacement Description
11.2 min. (215w)
12
RBC51
Battery access door
Hot-swappable, user replaceable batteries
LEDS ALARMS & SWITCHES
LED Indicators
Audible Alarm
Alarm Cancel Operation
Switches
3 LEDs indicate line power, battery power and battery low/replace status
Audible alarm indicates power-failure and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
UPS AC Suppression Response
Time
UPS Dataline Suppression
EMI / RFI AC Noise Suppression
AC Suppression Response Time
Dataline Suppression
510
Instantaneous
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
Yes
Instantaneous
1 line TEL / DSL or 10Base T Ethernet protection
PHYSICAL
Installation Form Factors Supported
with Included Accessories
Installation Form Factors Supported
with Optional Accessories
Primary Form Factor
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
UPS Power Module Weight (lbs.)
UPS Power Module Weight (kg)
UPS Shipping Dimensions (hwd / in.)
UPS Shipping Dimensions (hwd /
cm)
Shipping Weight (lbs.)
Shipping Weight (kg)
Tower
Wallmount (UPSWM - tower mounting kit)
Tower
10.8 x 5.2 x 7.5
27.3 x 13.3 x 19
15.2
6.9
14 x 8.5 x 10.5
35.6 x 21.6 x 26.7
17.2
7.8
3/5
UPS Housing Material
PVC
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC Mode BTU / Hr. (Full Load)
Battery Mode BTU / Hr. (Full Load)
AC Mode Efficiency Rating (100%
Load)
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
44.7
407.6
97%
COMMUNICATIONS
Communications Interface
PowerAlert Software
Communications Cable
WatchDog Compatibility
Network UPS Tools Compatibility
USB (HID enabled)
Free download from www.tripplite.com
USB interface cable included
Supports Watchdog application, OS and hard-reboot restart options for remote applications
NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at
http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
LINE / BATTERY TRANSFER
Transfer Time
Low Voltage Transfer to Battery
Power (Setpoint)
High Voltage Transfer to Battery
Power (Setpoint)
2-4 milliseconds
99 (adjustable to 83 via back panel potentiometer)
139
SPECIAL FEATURES
Cold Start (Startup in Battery Mode
During a Power Failure)
High Availability UPS Features
Green Energy-Saving Features
Cold-start operation supported
Hot swappable batteries
Greater than 95% efficiency - GREEN UPS
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
Model: BearPi-HM MicroFrom: Nanjing BearPi Intelligent Technology Co., Ltd.Quantity: 2 pieces
The BearPi-HM Micro development board is a highly integrated development board that can run the Openharmon...
Helping a friend to post this news, please support us! As the title says! Sincerely invite WINCE technology experts in Beijing to join the "Embedded Technology Outsourcing Group", which will release s...
After the DVD player is turned on, the "PSCAN" warning appears when using the AV output screen and the screen is split into two halves, the same phenomenon occurs when using the S-terminal component, ...
My friend asked me to find someone to help me. If you have written such a program, please leave a message or send me a private message. The price is negotiable....
Dear experts, I have a question for you: We know that when my C wants to reference the functions in the library file, I just need to add include that lib in the source, and then, in the C language, us...
[i=s]This post was last edited by damiaa on 2017-5-1 21:59[/i] KW41Z+Learn to use the development environment (turn on the light) After getting any development board, it is necessary to turn on the li...
In this article, the high-performance DSP developed by TI can be used as an effective confidentiality method if it is applied to PC encryption cards.
As an effective network security solution,...[Details]
From the PIC16F946 datasheet, we know that there are two ways to write values to the LCD for display:
1. Directly write the value to LCDDATA1~LCDDATA23
2. Use disconnect t...[Details]
Contact resistance
is the resistance to current flow through a closed pair of contacts. This type of measurement is performed on devices such as connectors,
relays
, and switches. The...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
1 Introduction to HART Protocol
HART (Highway Addressable Remote Transducer), an open communication protocol for addressable remote sensor high-speed channels, was launched by Rosemen in the U...[Details]
VP2188 is a color STN LCD module produced by Jingdian Pengyuan. This module is a dot matrix transmissive color STN display screen with a color scale of 65 k colors and white LED backlight. Its core...[Details]
OC faults may be the most frequent and the most frequent of all faults in the inverter. They alarm during the startup process, during the shutdown process, during operation, and even when powered o...[Details]
According to the Industrial Technology Research Institute of Taiwan, due to factors such as the oil crisis and global warming, the issues of energy conservation and environmental protection have at...[Details]
Preface
In recent years, white light LEDs have gradually replaced incandescent bulbs and fluorescent lamps because they have unparalleled advantages over traditional light sources in terms...[Details]
System Overview
The system consists of a signal preprocessing circuit, a single-chip computer AT89C2051, a systematic LED display module, a serial port data storage circuit and system software...[Details]
0 Introduction
With the rapid development of social economy and science and technology, electric locomotives, subways and electric vehicles will be widely used. The power conversion and cont...[Details]
With the rapid development of wireless
digital communication
, more challenges have been raised for integrated circuit design and testing. In the product design stage, in order to ensure
t...[Details]
The launch of Shenzhou IX is imminent, and Tiangong is welcoming visitors again. Yesterday, Professor Fu Qiang, Vice President of the Institute of Science and Industrial Technology of Harbin Instit...[Details]
Our flight had just begun to descend when a gentleman sitting next to me turned to talk to me about engineering—he had seen me reading an engineering journal. The gentleman next to me said that he ...[Details]
A few days ago, I bought an 8LED flashlight in the market (the flashlight uses No. 5 batteries). Because I had other things to do, I didn't pay attention when purchasing it. When I got home and use...[Details]