EEWORLDEEWORLDEEWORLD

Part Number

Search

EXR221K2CBA16X36T1

Description
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 160V, 10% +Tol, 10% -Tol, 220uF, Through Hole Mount, RADIAL LEADED
CategoryPassive components    capacitor   
File Size166KB,4 Pages
ManufacturerHitano Enterprise Corp
Environmental Compliance
Download Datasheet Parametric View All

EXR221K2CBA16X36T1 Overview

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 160V, 10% +Tol, 10% -Tol, 220uF, Through Hole Mount, RADIAL LEADED

EXR221K2CBA16X36T1 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid1240320753
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
capacitance220 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
dielectric materialsALUMINUM (WET)
leakage current1.056 mA
Installation featuresTHROUGH HOLE MOUNT
negative tolerance10%
Number of terminals2
Maximum operating temperature105 °C
Minimum operating temperature-25 °C
Package shapeCYLINDRICAL PACKAGE
method of packingBULK
polarityPOLARIZED
positive tolerance10%
Rated (DC) voltage (URdc)160 V
ripple current590.4 mA
surface mountNO
Delta tangent0.12
Terminal surfaceNOT SPECIFIED
Terminal shapeWIRE
EXR
SERIES
EXR series capacitors are ideal for use in switching power supplies. 
Other High Frequency Applications. 
Low Impedance and long life.
Characteristics
Voltage Range
Capacitance Range
Temperature Range
Leakage Current
Capacitance Tolerance
Dissipation Factor
6.3 to 100 VDC
4.7 to 15000uF
-40 to +105
160 to 450 VDC
1 to 470uF
-25 to +105
I≦0.01CV or 2uA, whichever is greater
I≦0.03CV or 3uA, whichever is greater
3 minutes after Rated Voltage applied
3 minutes after Rated Voltage applied
±20%
at 120Hz , 20
( 10% Tol. is available upon request)
Working Voltage (V)
6.3
10
16
25
35
50
63
9
100
8
22
19
16
14
12
10
tanδ(%)
max
Working Voltage (V)
160
200
250
350
400
450
12
12
12
15
15
17
tanδ(%)
max
For capacitance > 1000uF, add 0.02 for every 1000uF.(at 20
, 120Hz)
Working Voltage (V)
6.3
10
16
25
35
50
4
3
3
3
3
3
Z-25
/Z 20
8
6
4
3
3
3
Z-40
/Z 20
Working Voltage (V)
160
200
250
350
400
450
2
2
3
5
5
6
Z-25
/Z 20
3
6
6
6
6
-
Z-40
/Z 20
For capacitance > 1000uF, add 0.5 every 1000uF for -25
/+20
add 1.0 every 1000uF for -40
/+20
Low temperature
Characteristics (120Hz)
63
2
3
100
2
3
Load life :
5 – 6.3ψ
10ψ
Life Hours
2000
3000
5000
After the rated voltage with
ripple current has been
applied for at 105
(160V½450V : 2000HRS )
Capacitance change
D.F. tanδ
Leakage current
Within
±20%
of initial value
200% or less of initial specified value
Less than initial specified value
Shelf life (at 105
)
After 1000 hrs no load: test the leakage current, capacitance and tan
δ
are same as load life value.
Drawing
p
5
2.0
0.5
6.3
2.5
0.5
8
3.5
0.5
10
5.0
0.6
13
5.0
0.6
16
7.5
0.8
18
7.5
0.8
Multiplier for R.C. vs Temparature
Temp.(℃)
Multiplier
45
60
70
85
95
105
2.10 1.90 1.65 1.40 1.25 1.00
Ripple Current Coefficients
Frequency (Hz)
Cap.(uF) / Hz
Cap.
10
10<Cap.≦100
100<Cap.≦1000
1000<Cap.
60
0.47
0.52
0.58
0.63
120
0.59
0.62
0.72
0.78
400
Multiplier
0.76
0.80
0.84
0.87
0.85
0.89
0.90
0.91
0.97
0.97
0.98
0.98
1
1
1
1
23
1K
10K
50K - 100K
Contents and characteristics of electrical testing
Electrical testing refers to all tests performed using electrical technology and tests performed on electrical systems and equipment (motors, electrical appliances, etc.). Electrical testing usually i...
一世轮回 Integrated technical exchanges
Generation of static electricity
Matter is composed of molecules, which are composed of atoms. Atoms are composed of negatively charged electrons and positively charged protons. Under normal conditions, the number of protons in an at...
wangqingtao Power technology
When the stc89c52 microcontroller uses external interrupt 0, can't ET1 be set to 1?
I used protues to simulate and found that when I used external interrupt 0 and turned on the overflow interrupt of timer 1 (ET1=1), the external interrupt would not be triggered and could only be set ...
赵怡彬 51mcu
How to measure the frequency converter accurately
Many users have reported that the input or output current and voltage values of the inverter measured by a multimeter are quite different from the rated values displayed on the inverter nameplate or m...
totopper Industrial Control Electronics
Wireless module 24L01 data and 51 program
[i=s] This post was last edited by paulhyde on 2014-9-15 04:04 [/i] Wireless module 24L01 information...
haozi_1989 Electronics Design Contest
Development of an intelligent high-voltage inverter DC power supply for electrostatic precipitator
Abstract: This paper introduces a high voltage inverter power supply for electrostatic precipitator. The main structure of the power supply, the working principle of the main circuit, and the working ...
binghuoshaonian Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1936  166  460  222  1596  39  4  10  5  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号