TCL300DA1-TTD2

Description
TIME DELAY BLOW ELECTRIC FUSE, 100A, 125VDC, INLINE/HOLDER
CategoryCircuit protection   
File Size107KB,2 Pages
ManufacturerETC1
Download Datasheet View All

TCL300DA1-TTD2 Overview

TIME DELAY BLOW ELECTRIC FUSE, 100A, 125VDC, INLINE/HOLDER

TYPE:
CATALOG NO.:
General Description
The CCL/TCL Series provides functional emer-
gency lighting in a variety of wattages up to 450
watts. High performance electronics and rugged
18 gauge steel construction ensure long-term life
safety reliability.
CCL/TCL Series
Housing
High Capacity Steel Emergency Lighting Units
6 and 12 Volt, 75 to 450 Watts
Wet Cell Lead Calcium Battery
Constructed of 18 gauge steel with a tan epoxy powder
coat finish.
Knockouts provided for mounting up to three lamp
heads.
Bi-color LED charge monitor/indicator and a “press-to
test” switch are located on the front of the cabinet.
Choice of wedge base, sealed beam tungsten, or halogen
lamp heads
Illumination
Illumination is accomplished with up to three
lamp heads mounted on the top of the unit. The
most popular lamp head for use with the CCL/TCL
Series is the “D” Series round sealed beam Par 36
tungsten lamp head. The “D” head is available up
to 30 watts.
Dimensions
CCL75, CCL100, CCL150, CCL225,
TCL150, TCL200
6.0”
(15.2 cm)
Electronics
120/277 VAC dual voltage input with surge-protected,
solid-state circuitry provides for a reliable charging
system.
Charging system is complete with low voltage
disconnect, AC lockout, brownout protection,
AC indicator lamp and test switch.
Includes two fused output circuits.
7.6”
(19.3 cm)
Shown: CCL150DL2
Battery
Low maintenance, free electrolyte, wet cell, lead
calcium battery
Specific gravity disk indicators show relative state
charge at a glance
Operating temperature range of battery is 65°F
(19°C)
to 85°F
(30°C)
12.0”
(30.5 cm)
16.0”
(40.6 cm)
TCL300, TCL450
6.0”
(15.2 cm)
12.0”
(30.5 cm)
Utilizes a fully automatic voltage regulated two-rate cur- Battery supplies 90 minutes of emergency power
rent limited solid-state charger -- initially provides a high
rate charge upon restoration of AC power, and provides
Code Compliance
trickle charge to maintain batteries at full capacity once UL 924 listed
float voltage is attained.
NFPA 101
Optional ACCU-TEST Self Diagnostics includes an auto-
NEC BOCA and OSHA illumination standard
matic 3 minute discharge test every 30 days. A manual
test is available from 1 to 90 minutes.
Performance
Warranty
27.0”
(12.7 cm)
Three year full electronics warranty
7.6”
(19.3 cm)
Input power requirements
120 VAC - 0.66 amps, 80 watts
277 VAC - 0.30 amps, 80 watts
One year full plus four year prorated battery warranty
Ordering Information
CCL
SERIES
CCL = 6 Volt
TCL = 12 Volt
150
DC
WATTAGE
6 Volt
75 = 75 Watts
100 = 100 Watts
150 = 150 Watts
225 = 225 Watts
12 Volt
(Includes standard voltmeter)
150 = 150 Watt
200 = 200 Watt
300 = 300 Watt
450 = 450 Watt
DL
LAMP
HEADS
6 Volt
DY = 8 Watt, Tungsten
DA = 18 Watt, Tungsten
DL = 25 Watt, Tungsten
DC = 30 Watt, Tungsten
12 Volt
DNY = 12 Watt, Tungsten
DE = 28 Watt, Tungsten
DK = 25 Watt, Tungsten
DG = 30 Watt, Tungsten
(Suggested lamp heads listed
above. Refer to the Accessories Section for
additional lamp head choices.)
2
# OF
HEADS
3 = Three
2 = Two
1 = One
TD1
FACTORY INSTALLED
OPTIONS
1
ACCESSORIES
A = Ammeter
2
ACF1 = 120 VAC Fuse
LMSHELF = Mounting Shelf 300-450W
ACF2 = 277 VAC Fuse
MXSHELF = Mounting Shelf 72-200W
ACP1 = 120 VAC Power Switch
ACP2 = 277 VAC Power Switch
AD = ACCU-TEST Self-Diagnostics
ADAL = ACCU-TEST with Alarm
ADTD = ACCU-TEST with Time Delay
3
DCP = DC Power Switch
EX = Special Input Transformer
(Specify voltage and frequency)
TD1 = 120 VAC Time Delay
3
TTD2 = 277 VAC Time Delay
3
V = Voltmeter
2
W = White Housing
Notes:
1) Some option combinations may impact UL list-
ing. consult factory for specifics.
2) Not available witj AD, ADAL, or ADTD options.
3) 15 minute delay.
C1063
R4
9/02 IH
I want to ask a question that should be relatively simple, but I haven't figured it out for several days.
The problem is this: I am currently debugging a chip that is read and written through iic. The iic driver has been prepared, and it should be included with 6410. The current problem is: I have used ii...
chenmengzhong Embedded System
Pay attention to these aspects when making PCB samples
Who will do PCB proofing? Generally speaking, there are two major groups who will do this. The first is the proofing manufacturer who mainly does PCB, and the second is the design engineer who mainly ...
中信华 PCB Design
I have also been promoted to a "ten thousand yuan household"
I'm posting this to commemorate my achievement. I'm also a "ten thousand yuan household". After spending so much money on ChipCoin, I finally said goodbye to the four-digit numbers and finally saw my ...
fengxin Talking
The driver was loaded and then immediately uninstalled
I am learning about stream drivers and wrote an empty driver. The driver was compiled into the kernel, but after loading, it was immediately unloaded. The output of the hyperterminal is GPI DLL_PROCES...
pxy94 Embedded System
DSP28335 Problem Summary
I just came into contact with the SCI module of F28335 recently. I encountered some problems in the debugging process. I hope that the seniors can give me some advice. 1. The configuration of some reg...
寒塘渡鹤 DSP and ARM Processors
About stm8s103k microcontroller serial communication
Please help me, is there any problem with this serial port sending program? ? I use a USB to serial port cable to connect to the TX and RX pins of the microcontroller. The data received on the serial ...
李亮123 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1956  1999  199  400  1878  40  41  5  9  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号