LP303515

Description
Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector   
File Size239KB,6 Pages
ManufacturerEaton
Download Datasheet Parametric View All

LP303515 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

LP303515 Parametric

Parameter NameAttribute value
Objectid1740798307
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSAFETY APPROVAL: UL 94V-0, THERMOPLASTIC
Fastening methodSCREW
Manufacturer's serial numberLP3000
Installation typeBOARD
Number of layers1
Rows1
Number of channels15
Rated current30 A
Rated voltage150 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
MAGNUM
®
A31940707WR
Series A3000, LP3000 & CB3000
Single Row Terminal Blocks
Single & Double Row
Filtered Connectors
Euro-MAG Series
PCB – Spring Clamp
SPECIFICATIONS
Rating:
A3:
30A, 600V* #12-22 AWG
LP3: 30A, 150V #12-22 AWG
CB3: 30A, 600V #12-22 AWG
Wire Range:
#12-22 AWG CU
Center Spacing:
.437” or 7/16” (11.10 mm)
Screw Size:
#6-32 zinc plated philslot screws.
Torque Rating:
9 in-lb.
Base:
Standoffs standard for easy flux washing.
Distance Between Barriers:
.32” (8.1 mm)
Recommended PCB Hole Diameter:
.076” (1.93 mm)
Operating Temperature:
105°C (221°F) max., -40°C
(-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3500V (A3 & LP3); 8200V (CB3)
Agency Information:
UL/CSA; IEC Compliance,
CE Certified
*30A Rating achieved with a #10 copper wire crimped to a ring terminal;
20 Rating without ring terminal.
LP301105
CB31420807
A3000 & LP3000 Series
.437
(11.10)
.15
(3.8)
dia.
.65
(16.5)
Base & Rail Mount
Connectors
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.31
1.75
2.18
2.62
3.06
3.50
3.93
4.37
4.81
5.25
5.68
6.12
6.56
7.00
7.43
7.87
8.31
8.75
9.18
9.62
10.06
10.50
10.93
11.37
11.81
1.73
2.17
2.61
3.05
3.48
3.92
4.36
4.80
5.23
5.67
6.11
6.55
6.98
7.42
7.86
8.30
8.73
9.17
9.60
10.05
10.48
10.92
11.36
11.80
12.23
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
.43
.87
1.31
1.75
2.18
2.62
3.06
3.50
3.93
4.37
4.81
5.25
5.68
6.12
6.56
7.00
7.43
7.87
8.31
8.50
9.18
9.62
10.06
10.50
10.93
11.37
11.81
BARRIER
ENDS
ONLY
C
Length
.98
1.43
1.87
2.31
2.75
3.18
3.62
4.06
4.50
4.93
5.37
5.81
6.25
6.68
7.12
7.56
8.00
8.43
8.87
9.31
9.75
10.18
10.62
11.06
11.50
11.93
12.37
.40
(10.2)
C
Mount End
Barrier End
.565
(19.3)
.76
(14.35)
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
CB3000 Series
.437
(11.10)
.19
(4.8)
dia.
.32
(8.1)
C
Mount End
Barrier End
Power Distribution Blocks
.70
(17.8)
.61
(15.5)
WIRE MANAGEMENT PRODUCTS
Dimensions in inches. To convert to millimeters, multiply by 25.4.
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
12
MSP432 GPIO configuration issues
I think GPIO functions are mainly divided into two categories: one is GPIO interrupt configuration function The following parameter settings are similar. The options for selectedPort areGPIO_PORT_P1GP...
fish001 Microcontroller MCU
[MSP430 Sharing] Multi-channel data acquisition and transmission system based on low power design
Taking the reduction of power consumption of the application system as the main technical indicator, an underwater magnetic field data acquisition and transmission system is designed. Starting from th...
鑫海宝贝 Microcontroller MCU
Which brother
[i=s] This post was last edited by paulhyde on 2014-9-15 09:29 [/i] Looking for information on inverter power supply and constant current source...
严波 Electronics Design Contest
Application of multi-sensor fusion positioning in high-speed railway
Application of multi-sensor fusion positioning in high-speed railway Date: June 18, 2010 Font: Large,Medium, SmallKeywords: Sensor data fusion Positioning system GPS GISIn 2009, the application of C3 ...
安_然 Test/Measurement
How to adjust the volume of WT588D by sending codes
Can anyone who has used WT588D tell me how to adjust the volume by sending a code in the one-line serial port mode? Is it sending an address or something else? Or is it using the one-line serial port ...
近猪者痴xp Microcontroller MCU
The premium industrial instrument control iocomp 3.04 green version – a boon for VB users!
[url=http://www.ourdev.cn/bbs/bbs_content.jsp?bbs_sn=3368822&bbs_page_no=1&bbs_id=9999][/url]Description[url=http://www.ourdev.cn/bbs/bbs_content.jsp?bbs_sn=3368822&bbs_page_no=1&bbs_id=9999]OURAVR[/u...
fish001 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 927  1869  2642  2079  561  19  38  54  42  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号