Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2. self-clinching terminal
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
2 Fom C
5V DC
6V DC
9V DC
12V DC
24V DC
48V DC
Single side stable
Part No.
TX2-H-1.5V
TX2-H-3V
TX2-H-4.5V
TX2-H-5V
TX2-H-6V
TX2-H-9V
TX2-H-12V
TX2-H-24V
TX2-H-48V
1 coil latching
Part No.
TX2-L-H-1.5V
TX2-L-H-3V
TX2-L-H-4.5V
TX2-L-H-5V
TX2-L-H-6V
TX2-L-H-9V
TX2-L-H-12V
TX2-L-H-24V
—
2 coil latching (L2)
Part No.
TX2-L2-H-1.5V
TX2-L2-H-3V
TX2-L2-H-4.5V
TX2-L2-H-5V
TX2-L2-H-6V
TX2-L2-H-9V
TX2-L2-H-12V
TX2-L2-H-24V
—
2 coil latching (LT)
Part No.
TX2-LT-H-1.5V
TX2-LT-H-3V
TX2-LT-H-4.5V
TX2-LT-H-5V
TX2-LT-H-6V
TX2-LT-H-9V
TX2-LT-H-12V
TX2-LT-H-24V
—
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
3. Surface-mount terminal
1) Tube packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
48V DC
Single side stable
Part No.
TX2S -1.5V
TX2S -3V
TX2S -4.5V
TX2S -5V
TX2S -6V
TX2S -9V
TX2S -12V
TX2S -24V
TX2S -48V
1 coil latching
Part No.
TX2S -L-1.5V
TX2S -L-3V
TX2S -L-4.5V
TX2S -L-5V
TX2S -L-6V
TX2S -L-9V
TX2S -L-12V
TX2S -L-24V
—
2 coil latching (L2)
Part No.
TX2S -L2-1.5V
TX2S -L2-3V
TX2S -L2-4.5V
TX2S -L2-5V
TX2S -L2-6V
TX2S -L2-9V
TX2S -L2-12V
TX2S -L2-24V
—
2 coil latching (LT)
Part No.
TX2S -LT-1.5V
TX2S -LT-3V
TX2S -LT-4.5V
TX2S -LT-5V
TX2S -LT-6V
TX2S -LT-9V
TX2S -LT-12V
TX2S -LT-24V
—
2c
: For each surface-mounted terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2) Tape and reel packing
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
48V DC
Single side stable
Part No.
TX2S -1.5V-Z
TX2S -3V-Z
TX2S -4.5V-Z
TX2S -5V-Z
TX2S -6V-Z
TX2S -9V-Z
TX2S -12V-Z
TX2S -24V-Z
TX2S -48V-Z
1 coil latching
Part No.
TX2S -L-1.5V-Z
TX2S -L-3V-Z
TX2S -L-4.5V-Z
TX2S -L-5V-Z
TX2S -L-6V-Z
TX2S -L-9V-Z
TX2S -L-12V-Z
TX2S -L-24V-Z
—
2 coil latching (L2)
Part No.
TX2S -L2-1.5V-Z
TX2S -L2-3V-Z
TX2S -L2-4.5V-Z
TX2S -L2-5V-Z
TX2S -L2-6V-Z
TX2S -L2-9V-Z
TX2S -L2-12V-Z
TX2S -L2-24V-Z
—
2 coil latching (LT)
Part No.
TX2S -LT-1.5V-Z
TX2S -LT-3V-Z
TX2S -LT-4.5V-Z
TX2S -LT-5V-Z
TX2S -LT-6V-Z
TX2S -LT-9V-Z
TX2S -LT-12V-Z
TX2S -LT-24V-Z
—
2 Form C
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available.
2. Please add “-1” to the end of the part number for AgPd contacts (low level load).
Standard contact: 2 A 30 V DC, AgPd contact: 1 A 30 V DC (resistive load)
Standard contact: 60 W (DC), AgPd contact: 30 W (DC) (resistive load)
220V DC
Standard contact: 2 A, AgPd contact: 1 A
10µA 10mV DC
140 mW (1.5 to 24 V DC), 270 mW (48 V DC)
100 mW (1.5 to 24 V DC)
200 mW (1.5 to 24 V DC)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA)
2,000 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10×160µs) (FCC Part 68)
2,500 V (2×10µs) (Telcordia)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Min. 750 m/s
2
(Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 10
8
(at 180 cpm)
Min. 10
5
(2 A 30 V DC resistive), 5×10
5
(1 A 30 V DC resistive) (at 20 cpm)
Ambient temperature: –40°C to +85°C (up to 24 V coil)
–40°F to +185°F (up to 24 V coil)
[–40°C to +70°C (48 V coil)
–40°F to +158°F (48 V coil)];
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 2 g
.071 oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level])
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
First of all, let me talk about the problem. I feel that this Code Compose Studio is quite strange.
#include "TFT\TFT_Driver.h"file not found, cannot be openedWithout include, the function can only be...
We are using SIMCOM700 module now. In addition to making calls and sending text messages, our product also supports browser surfing. I checked some information on the Internet. If you want to surf the...
I just saw the G2553 routine ADC10_16. There is a sentence ADC10SA = (unsigned int)TACCR1; // Data transfer location. The initial value of TACCR1 is 512. After running, the value of ADC10SA changes to...
RT, I want to use LFB182G45BG2D280 to connect the PCB antenna. This is my first time to build a Bluetooth board. The PCB reference design file I downloaded from TI's official website cannot be opened ...