550C123T200DE1A

Description
Aluminum Electrolytic Capacitor, Polarized, Aluminum, 200V, 50% +Tol, 10% -Tol, 12000uF,
CategoryPassive components    capacitor   
File Size432KB,8 Pages
ManufacturerCDE [ CORNELL DUBILIER ELECTRONICS ]
Environmental Compliance
Download Datasheet Parametric View All

550C123T200DE1A Overview

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 200V, 50% +Tol, 10% -Tol, 12000uF,

550C123T200DE1A Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid844346261
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
capacitance12000 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
diameter76.81 mm
dielectric materialsALUMINUM
ESR11.5 mΩ
length130.942 mm
negative tolerance10%
Number of terminals2
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
Package formScrew Ends
polarityPOLARIZED
positive tolerance50%
Rated (DC) voltage (URdc)200 V
ripple current27000 mA
series550C
Terminal pitch31.75 mm
Type 550C 105 °C High Ripple, Inverter Grade, Aluminum
Ultra-Ripple, Long Life Screw Terminal Type
Type 550C is the standard for motor drive and other high-ripple, long-
life applications. It boasts more than 25% extra ripple capability per
can size, but less capacitance than Type 520C. Expected operating
life is more than 100,000 hours in typical applications. Type 550C is
rated for 10,000 h life with full ripple current, rated voltage, 85 ºC and
100 lfm airflow while mounted horizontally. Horizontal mounting is
more severe than vertical mounting. The extended cathode foil of the
550C assures heat flow from the capacitor element to the can in all
orientations.
Highlights
Specifications
Temperature Range
Rated Voltage Range
Capacitance Range
Capacitance Tolerance
Leakage Current
Ripple Current Multipliers
- 10,000 hour load life
- Ripple current to 105 amps
- ESRs to 7 mΩ
–40 °C to +105 °C
200 Vdc to 500 Vdc
91 µF to 35,000 µF
–10% +50%
≤3 √CV µA, 4 mA max, 5 minutes
Ambient Temperature
45 ºC
1.66
Frequency
55 ºC
1.52
65 ºC
1.37
75 ºC
1.20
85 ºC
1.00
95 ºC
0.75
105 ºC
0.36
50 60 120 360
Hz Hz Hz Hz
1 3/8” & 2 1/2” Diameters
200 to 350 V
0.77 0.82 1.00 1.21
400 to 500 V
0.73 0.78 1.00 1.33
3” & 3 1/2” Diameters
200 to 350 V
0.80 0.85 1.00 1.17
400 to 500 V
0.73 0.79 1.00 1.31
1
5 10 kHz
kHz kHz & up
1.32 1.37 1.38
1.53 1.66 1.68
1.24 1.28 1.29
1.51 1.63 1.65
Low Temperature Characteristics
Endurance Life Test
Impedance ratio: Z
–20⁰C
∕ Z
+25⁰C
≤ 3 (200–500 Vdc)
10,000 h at full load at 105 °C
∆ Capacitance ±20%
ESR 200% of limit
DCL 100% of limit
500 h at 105 °C
Capacitance 100% of limit
ESR 100% of limit
DCL 100% of limit
10 to 55 Hz, 0.06” and 10 g max, 1.5 h each of two axis
RoHS Compliant
Shelf Life Test
Vibration
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800
"ADI Laboratory Circuit DIY Competition" is officially launched!
After the previous round of [Community Lectures], are you also itching to try it? If you want to - experience the convenience brought by laboratory circuits? - enjoy the feeling of creativity? - find ...
EEWORLD社区 ADI Reference Circuit
Is there a big difference between ATmega2560 and ATxmega128 series microcontrollers?
[color=#000000][size=14px][backcolor=rgb(222, 240, 251)][font=Tahoma, "]There is a project that requires 5 serial ports. Previously, ATmega2560 only had 4. [/font][/backcolor] [backcolor=rgb(222, 240,...
进击的生菜 Microchip MCU
EEWORLD University ---- Engineer It: How to overcome temperature differences in the engine block
Engineer It: How to overcome temperature differences in an engine block : https://training.eeworld.com.cn/course/219...
cuipin Talking
How to use HART protocol for data transmission
I would like to ask you how to use the HART protocol to transmit data?...
大象 Test/Measurement
9b96 cannot be downloaded, it seems to be locked
Hello everyone, I have a Yutu LM3S9B96 board. I usually use the ICDI of EKK-LM3S8962 to debug and burn. But today the clock is wrong, so I can't burn the program. Can I use EKK-LM3S8962 to unlock it, ...
zhouqianghfut Microcontroller MCU
Fourier Transform
The amplitude of the AC signal is constantly changing, and the voltage and current of the signal added to the load are also constantly changing. Now to calculate the power of the load we have to use i...
yjj1987 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 620  376  2640  1080  1812  13  8  54  22  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号