CAPACITOR, CERAMIC, MULTILAYER, 100 V, BX, 0.12 uF, SURFACE MOUNT, 1825, CHIP, HALOGEN FREE
CategoryPassive components    capacitor   
File Size140KB,17 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance  
Download Datasheet Parametric View All

CDR35BX124BMYPAT Overview

CAPACITOR, CERAMIC, MULTILAYER, 100 V, BX, 0.12 uF, SURFACE MOUNT, 1825, CHIP, HALOGEN FREE

CDR35BX124BMYPAT Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid2143377254
package instruction, 1825
Reach Compliance Codecompliant
ECCN codeEAR99
capacitance0.12 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high1.5 mm
JESD-609 codee3
length4.5 mm
Installation featuresSURFACE MOUNT
multi-layerYes
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package shapeRECTANGULAR PACKAGE
Package formSMT
method of packingTR, EMBOSSED PLASTIC, 7 INCH
positive tolerance20%
Rated (DC) voltage (URdc)100 V
GuidelineMIL-PRF-55681/11
size code1825
surface mountYES
Temperature characteristic codeBX
Temperature Coefficient15% ppm/°C
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
Terminal shapeWRAPAROUND
width6.4 mm
CDR-MIL-PRF-55681
www.vishay.com
Vishay Vitramon
Surface Mount Multilayer Ceramic Chip Capacitors
MIL Qualified, Type CDR
FEATURES
• Military qualified products
• Federal stock control number,
CAGE CODE 2770A
• High reliability tested per MIL-PRF-55681
• Tin / lead termination codes “W”, “Z”, and “U”
• Lead (Pb)-free termination codes “Y” and “M”
• Wet build process
• Reliable Noble Metal Electrode (NME) system
• Material categorization: for definitions of compliance
please see
www.vishay.com/doc?99912
Note
*
This datasheet provides information about parts that are
RoHS-compliant and / or parts that are non RoHS-compliant. For
example, parts with lead (Pb) terminations are not RoHS-compliant.
Please see the information / tables in this datasheet for details
Available
Available
APPLICATIONS
• Avionic systems
• Sonar systems
• Satellite systems
• Missiles applications
• Geographical information systems
• Global positioning systems
ELECTRICAL SPECIFICATIONS
Note
Electrical characteristics at +25 °C unless otherwise specified
Operating Temperature:
-55 °C to +125 °C
Capacitance Range:
1.0 pF to 470 nF
Voltage Range:
6.3 V
DC
to 100 V
DC
Temperature Coefficient of Capacitance (TCC):
BP: 0 ppm/°C ± 30 ppm/°C from -55 °C to +125 °C,
with 0 V
DC
applied
0 ppm/°C ± 30 ppm/°C from -55 °C to +125 °C,
with 100 % rated V
DC
applied
BX: ± 15 % from -55 °C to +125 °C, with 0 V
DC
applied
BX: +15 %, -25 % from -55 °C to +125 °C,
with 100 % rated V
DC
applied
BR: ± 15 % from -55 °C to +125 °C,
with 0 V
DC
applied
+15 %, -40 % -55 °C to +125 °C,
with 100 % rated V
DC
applied
Dissipation Factor (DF):
BP: 0.15 % maximum
BX: 2.50 % maximum
BR:
25 V: 3.5 % maximum
> 25 V: 2.5 % maximum
Test frequency:
1 MHz ± 50 kHz for BP capacitors
1000 pF
and for BX capacitors
100 pF
All other BP, BX, and BR at 1 kHz ± 50 Hz
Aging Rate:
BP: 0 % maximum per decade
BX, BR: 1 % maximum per decade
Insulation Resistance (IR):
at +25 °C and rated voltage 100 000 M minimum or
1000
F,
whichever is less
Dielectric Strength Test:
performed per method 103 of EIA-198-2-E.
Applied test voltages:
100 V
DC
-rated: 250 % of rated voltage
Revision: 30-Jun-2020
Document Number: 45026
1
For technical questions, contact:
mlcc@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
What is the difference between LWPOLYLINE and POLYLINE in dxf file
What is the difference between LWPOLYLINE and POLYLINE in dxf files? In addition, does the POLYLINE part only have line segments connected by VERTEX?...
pppphzmns Embedded System
I have some simple problems encountered by arm beginners. I hope everyone can give me some advice!
Hello everyone, I just got started with ARM, and I encountered a lot of problems at the beginning. I want to light up the two digital tubes on the development board. The board is burned with Win CE 5....
sleepdragon1986 ARM Technology
How to use privilege level in vxworks6.6
As the title says. vxworks6.6 has implemented the isolation between kernel and user space. It seems that the service is provided through system calls, which are generally implemented using privileged ...
gsypuma Real-time operating system RTOS
How to understand Howland circuit
This is a circuit built with an op amp. Using the virtual short and virtual open methods, we can analyze that the current flowing through RL has nothing to do with the resistance value of RL, but only...
bigbat Analog electronics
A brief discussion on negative feedback
① Single 1Ω ② 50 50Ω in parallel ③ Single 50Ω/(1+β), β=49, Ube≈0V The three solutions are equivalent, but not equivalent! [/font][/size][/align]...
hk6108 Analog electronics
Regarding the issue of 74LS138.
In my design, I first expanded a 6264 (the single-chip microcomputer uses P0 and P2 ports, uses a latch 74LS373, a decoder 74LS138, and the address lines are A13, A14, and A15). However, my design als...
climbar Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1092  742  913  1443  2198  22  15  19  30  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号