TekProbe interface (P5202A, P5205A, and P5210A Series probes)
®
®
Safe high-voltage probe solutions
The THDP0100 and P5210A have the largest differential dynamic range
capability from Tektronix, allowing users to safely measure up to ±6000 V.
The THDP0100 supports bandwidths up to 100 MHz and slew rates up to
2500 V/ns at 1/1000 gain. These probes are supplied with two sizes of hook
tips and have an overrange visual and audible indicator which warns the
user when they are exceeding the linear range of the probe.
The THDP0200 and P5205A are active differential probes that are capable
of safely measuring differential voltages up to ±1500 V. The probes are
effective in making measurements in IGBT circuits such as motor drives and
power converters. The THDP0200 supports bandwidths up to 200 MHz and
slew rates up to 275 V/ns at 1/250 gain.
The TMDP0200 and P5202A are designed for medium-voltage applications
with differential requirements up to ±750 V. These probes have lower
attenuation ranges and offer better signal-to-noise ratio.
The P5200A can be used with any oscilloscope and enables users to safely
make measurements of floating circuits with their oscilloscope grounded.
The P5200A Active Differential Probe converts floating signals to low-
voltage ground-referenced signals that can be displayed safely and easily
on any ground-referenced oscilloscope.
Tektronix offers a broad portfolio of high-voltage probing solutions that
enable users to safely and accurately make floating measurements.
Key performance specifications
Bandwidths up to 200 MHz
Up to 6000 V differential (DC + pk AC)
Up to 2300 V common (RMS)
Key features
Overrange Indicator
Safety Certified
Switchable Attenuation
Switchable bandwidth limit
Applications
Floating measurements
Switching power supply design
Motor drive design
Electronic ballast design
CRT display design
Power converter design and service
Power device evaluation
Datasheet
Connectivity options
The TMDP and THDP Series probes are equipped with the TekVPI
interface which allows smart communication between the oscilloscope and
probe. Pushing the probe menu button will launch the probe control menu
on the oscilloscope display providing access to all relevant probe settings
®
and controls. These probes are designed to operate on TekVPI
oscilloscopes without requiring the TPA-BNC adapter.
®
The P52xxA Series probes are equipped with the Tektronix TekProbe
interface which communicates scale information to the oscilloscope. Direct
®
connections can be made to oscilloscopes configured with the TekProbe
®
interface or to any oscilloscope when used with the 1103 TekProbe Power
Supply.
®
Specifications
All specifications apply to all models unless noted otherwise.
Model overview
Probes with the TekVPI
®
interface
TMDP0200
Attenuation
Differential Voltage
Common Mode Voltage
Maximum Input Voltage-to-Earth
Bandwidth
Rise Time
Slew Rate
Input Impedance at the Probe Tip
Typical CMRR
25X / 250X
250X: ±750 V
25X: ±75 V
±750 V
550 V CAT I
300 V CAT III
200 MHz
<1.8 ns
<275 V/ns at 1/250 gain
5 MΩ || <2 pF
DC: > -80 dB
100 kHz: > -60 dB
3.2 MHz: > -30 dB
100 MHz: > -26 dB
1.5 m
THDP0200
50X / 500X
500X: ±1500 V
50X: ±150 V
±1500 V
1000 V CAT II
600 V CAT III
200 MHz
<1.8 ns
<650 V/ns at 1/500 gain
10 MΩ || <2 pF
DC: > -80 dB
100 kHz: > -60 dB
3.2 MHz: > -30 dB
100 MHz: > -26 dB
1.5 m
THDP0100
100X / 1000X
1000X: ±6000 V
100X: ±600 V
±6000 V
2300 V CAT I
1000 V CAT III
100 MHz
<3.5 ns
<2500 V/ns at 1/1000 gain
40 MΩ || <2.5 pF
DC: > -80 dB
100 kHz: > -60 dB
3.2 MHz: > -30 dB
100 MHz: > -26 dB
1.5 m
Cable Length
Probes with the BNC and TekProbe
®
interface
P5200A
Attenuation
Differential Voltage
Common Mode Voltage
50X / 500X
500X: ±1300 V
50X: ±130 V
±1300 V
P5202A
20X / 200X
200X: ±640 V
20X: ±64 V
±640 V
450 V CAT l
300 V CAT ll
100 MHz
5 MΩ || 2 pF
2.5 MΩ || 4 pF
DC: >80 dB
100 kHz: >60 dB
3.2 MHz: >40 dB
50 MHz: >30 dB
P5205A
50X / 500X
500X: ±1300 V
50X: ±130 V
±1300 V
1000 V CAT II
100 MHz
10 MΩ || 2 pF
5 MΩ || 4 pF
P5210A
100X / 1000X
1000X: ±5600 V
100X: ±560 V
±5600 V
2300 V CAT l
1000 V CAT III
50 MHz
40 MΩ || 2.5 pF
20 MΩ || 5 pF
Maximum Input Voltage-to-Earth 1000 V CAT II
Bandwidth
Differential Input Impedance
Input Impedance between each
Input and Ground
Typical CMRR
50 MHz
10 MΩ || 2 pF
5 MΩ || 4 pF
DC: >80 dB
100 kHz: >60 dB
3.2 MHz: >30 dB
50 MHz: >26 dB
1.8 m
Cable length
2 www.tektronix.com
1. The differential voltageis the maximum measurable range between the (+) and (-) input leads of the probe. Beyond these limits, the output could be clipped.
2. The maximum common mode voltage and maximum input voltage-to-earth (RMS) are the maximum voltages that each input lead (+/-) can be from ground.
Ordering information
Standard accessories
P5200A, P5202A, and P5205A
Description
Hook clips
Pincer clips
Alligator clips
Extension cables
Quantity included
1 set of red and black hook clips
1 set of red and black pincer clips
1 set of red and black alligator clips
1 set of red and black extension cables
Reorder part number
AC280-FL
AC283-FL
AC285-FL
196-3523-00
TMDP0200 and THDP0200
Description
Hook clips
Pincer clips
Alligator clips
Extension cables
Test leads
High voltage differential browser
Probe holder
Quantity included
2
2
2
2
2
1
1
Reorder part number
AC280-FL
AC283-FL
AC285-FL
196-3523-00
TP175-FL
THV-BROWSER
TPH1000
www.tektronix.com 3
Datasheet
THDP0100 and P5210A
Description
Probe tips
Large hook clips
Small hook clips
Probe heads
Quantity included
2
2
2
2
Reorder kit part number
020-3070-00
Probe and Accessory Derating Table
Common mode, relative to ground, when used with P52xxA Series probes
Accessory
Description
TMDP0200 / P5202A
450 V CAT I
300 V CAT II
Standard
450 V CAT I
300 V CAT II
Standard
450 V CAT I
300 V CAT II
Standard
450 V CAT I
300 V CAT II
Standard
450 V CAT I
300 V CAT II
Optional
450 V CAT I
300 V CAT II
Standard (TMDP0200)
550 V CAT I
300 V CAT III
THDP0200 / P5200A / P5205A
1000 V CAT II
600 V CAT III
Standard
1000 V CAT II
600 V CAT III
Standard
1000 V CAT II
600 V CAT III
Standard
1000 V CAT II
600 V CAT III
Standard
1000 V CAT II
600 V CAT III
Optional
1000 V CAT II
600 V CAT II
Standard (THDP0200)
1000 V CAT II
600 V CAT III
THDP0100 / P5210A
2300 V CAT I
1000 V CAT III
Standard
2300 V CAT I
1000 V CAT III
Optional
1000 V CAT I
1000 V CAT III
Optional
1000 V CAT I
1000 V CAT III
Optional
1000 V CAT I
1000 V CAT III
Standard
2300 V CAT I
1000 V CAT II
Optional
2300 V CAT I
1000 V CAT III
196-3523-00
2x Extender Leads (1.5 m)
2300 V CAT I
1000 V CAT III
2x Hook Clips
1000 V CAT III
600 V CAT IV
2x Pincer Clips
1000 V CAT III
600 V CAT IV
2x Alligator Clips
1000 V CAT III
600 V CAT IV
Hook Clip Kit
2300 V CAT I
1000 V CAT II
2x Test Leads
1000 V CAT III
600 V CAT IV
AC280-FL
AC283-FL
AC285-FL
020-3070-00
TP175-FL
Options
Power plug options (P5200A only)
Opt. A0
Opt. A1
Opt. A2
Opt. A3
Opt. A4
Opt. A5
Opt. A6
Opt. A10
Opt. A11
Opt. A12
Opt. A99
North America power plug (115 V, 60 Hz)
Universal Euro power plug (220 V, 50 Hz)
United Kingdom power plug (240 V, 50 Hz)
Australia power plug (240 V, 50 Hz)
North America power plug (240 V, 50 Hz)
Switzerland power plug (220 V, 50 Hz)
Japan power plug (100 V, 110/120 V, 60 Hz)
China power plug (50 Hz)
India power plug (50 Hz)
Brazil power plug (60 Hz)
No power cord
4 www.tektronix.com
Service options
Opt. C3
Opt. C5
Opt. D1
Opt. D3
Opt. D5
Opt. R3
Opt. R5
Opt. SILV200
Calibration Service 3 Years
Calibration Service 5 Years
Calibration Data Report
Calibration Data Report 3 Years (with Opt. C3)
Calibration Data Report 5 Years (with Opt. C5)
Repair Service 3 Years (including warranty)
Repair Service 5 Years (including warranty)
Standard warranty extended to 5 years
Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the datasheet of each probe and accessory model for its unique warranty
and calibration terms.
The P52xxA Series probes provide high-voltage differential measurement solutions for
any oscilloscope.
Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar.
I watched Guo Tianxiang’s video. . The function code for scanning the keyboard is too long. Is there anything simpler? . [code] uchar keyscan() { P3=0xfe; temp=P3; temp=temp&0xf0; while(temp!=0xf0) { ...
When using GPIO external interrupts in sys/bios, that is, sending external interrupts to GPIO5 through FPGA, and then the DSP responds to the interrupt service program. In addition to configuring HWI ...
Innosound has no speaker or cabinet. Its sound-generating principle is different from that of traditional speakers that rely on their own cabinets. It can produce perfect sound as long as it resonates...
Since the medical electronics section is not well-received, I want to hold an event to increase its popularity. The event is initially planned to let me offer suggestions for medical electronics. I su...
The rapid development of the Internet has realized high-speed information transmission and resource sharing, greatly facilitating people's lives. Embedded systems are widely used in various electr...[Details]
introduction
1 The significance of using RTOS on MSP430
It is understandable that it is meaningless to use RTOS on MSP430. Because the hardware resources of MSP430 are limited (for exampl...[Details]
introduction
Solar cells and LED lighting are typical applications of new energy and energy-saving and efficient technologies. Solar LED lighting uses solar cells to convert solar energy...[Details]
In public places such as schools, government agencies, factories and mines, as well as public corridors in residential areas, the phenomenon of long-burning lights is very common, which causes a h...[Details]
Images in science fiction movies often break through the limits of reality, such as in the movie "Minority Report." Tom Cruise uses a multi-touch screen to browse information. Capacitive sensing te...[Details]
introduction
The emergence of high-performance, low-power embedded CPUs and high-reliability network operating systems has made it possible to implement applications with large amounts of comp...[Details]
AD8205 is
a single-supply high-performance differential
amplifier
launched by
Analog
Devices of the United States
. The typical single-supply voltage is 5V, and its common-mode volta...[Details]
1 Introduction
Water resources are the basic conditions for human survival and the lifeline of economic development. The reality shows that due to the global shortage of water resources and th...[Details]
Xiaomi, a well-known Internet phone in mainland China, won a million-unit order contract from China Unicom on November 20 last year, which made Xiaomi famous in mainland China. In April this year...[Details]
The concept of state machine
State machine is an important concept in software programming. More important than this concept is its flexible application. In a clear and efficient program, ther...[Details]
Continuity test
A variety of devices need to be checked for continuity, including cable assemblies, printed circuit boards, and connectors to ensure that these components have the expected contin...[Details]
Since the late 1990s, with the demand for higher system efficiency and lower power consumption, the technological update of telecommunications and data communication equipment has promoted the deve...[Details]
a. Keep the battery clean, wipe off the spilled electrolyte, contaminated dirt and dust in time; keep the poles and terminal clamps clean and in good contact, and apply vaseline or butter to preven...[Details]
Rated capacity refers to the maximum output power of the UPS (the product of voltage V and current A).
Usually, the UPS power supplies sold on the market are marked with "W" (watt) for smaller...[Details]
The most important components of new energy electric vehicles are power batteries, electric motors and energy conversion control systems. The power battery must achieve high performance such as fas...[Details]