SURE STAR COMPUTER CO., LTD
No. 2-1, Daan Road, Shulin Dist., New Taipei City 238, Taiwan
E-mail: info@surestar.com.tw
http: //www.surestar.com.tw
Tel: +886 2 2682 2505
Fax: +886 2 2682 2515
1U Redundant Power Supply
Model No. TC-300R2UH
Revision: A1
Table of content
1. Introduction............................................................................................2
2. Specification
2.1 Input Voltage.....................................................................................2
2.2 DC Output.........................................................................................2
2.3 PS-ON (Remote ON/OFF)................................................................3
2.4 PW-OK(power good signal)...............................................................3
2.5 Efficiency...........................................................................................3
2.6 Hold-Up Time.....................................................................................3
3. PROTECTION
3.1 Over Voltage protection....................................................................3
3.2 Short Circuit Protection.....................................................................3
3.3 Over Power Protection......................................................................4
3.4
No Load operation.............................................................................4
4. Environment Temperature......................................................................4
5. Reliability..................................................................................................4
6. Agency approvals....................................................................................4
7. EMI/RFI......................................................................................................4
8. Instructions...............................................................................................4
9. HOT-SWAP Procedures............................................................................5
10. Dimension..................................................................................................5
11. PINOUTS of connectors............................................................................7
Color Reference for LED cable.................................................................7
Main Power Connector..............................................................................7
①
1. Introduction
The 300R2UH Series products of
Hot-Swap & Power Sharing
redundant
Power supply provides increased reliability when integrated a variety of
Systems. The 300R2UH series is ideally suited to telecommunications and
Industrial system, as well as a variety of other applications where system
Never shut down i. E. Zero down time.
300R2UH
series redundant power supply, it consists of
*
One of passive Back plane.
*
One of exothermal enclosure.
*
Two of compact size power modules with Hot-Pluggable connector
*
Screw package.
*
Alarm reset bottom.
◎Features
*
1U Size design.
*
Hot-Swappable & Power Sharing capability.
*
Full Range AC input.
*
Active PFC meet
2. Specification
2.1 AC Input Voltage: 100 to 240VAC, Frequency: 47Hz~63 Hz.
2.2 DC Output: 300W maximum
VOLTAGE
MAX. LOAD
MIN. LOAD
REGULATION
RIPPLE(mV)
+5V
25A
3A
± 5%
50
+12V
16A
2A
± 5%
120
+3.3V
25A
0.3A
± 5%
50
-12V
0.8A
0.1A
±10%
120
-5V
0.5A
0.1A
±10%
100
+5Vsb
2A
0.1A
± 5%
50
Note:
1. The combined total power from +5V and +3.3V shall not exceed 40A.
The combined total power from +5V and +3.3V & +12V shall not exceed
278W
2. Noise Test – Noise bandwidth is from DC to 20 MHz.
3.Ripple frequencies greater than 1MHz shall be attenuated by the
measurement System.
4.Add 0.1uF/10uF capacitor at output connector terminals for ripple and noise
measurements.
②
2.3
PS-ON
Remote On/Off Control:
When PS-ON is pulled to TTL Low, the DC output is to be enabled.
When PS-OFF is pulled to TTL high, the DC output is to be disabled.
2.4
PW-OK
PW-OK is power good signal and should be asserted high by the power
supply to indicate that +5VDC and +3.3VDC output are above the under
voltage thresholds of the power supply TTL. compatible signal out with
100ms to 500ms.
Timing of PS-ON, PW-OK, and Germane Voltage Rails
Although there is no requirement to meet specific timing parameters,
The following signal timings are recommended:
2ms≦T2≦200ms
100ms≦T3≦500ms
T4>1ms
T5≦10ms
2.5 Efficiency:
≧
73﹪at full load. (Normal Line)
2.6 Hold-Up Time: 16ms at maximum load & normal input voltage.
3. PROTECTIONS
3.1 OVER-VOLTAGE PROTECTION
Standard on +5.0V output, set at 6.25VDC ± 075VDC.
3.2 SHORT CIRCUIT PROTECTION
A short circuit placed between the DC Return and the output shall cause
No damage and the power supply shall shutdown.
③
3.3 OVER POWER PROTECTION
The power supply shall shut down when output power exceeds 130﹪to 160﹪
of full load and require a power on cycle be performed by the operate.
3.4 NO LOAD OPERATION
No parts shall be damaged on the power supply.
4. ENVIRONMENT TEMPERATURE
4.1 Operation Temperature: 0℃ to 40℃
4.2 Cooling: By forced air
4.3 Storage Temperature:-20℃ to 70℃
4.4 Humidity: 5 to 90﹪non-condensing.
5. RELIABILITY
5.1 MTBF OF POWER SUPPLY ELECTRONIS
100,000 hours at full load and 25℃ ambient temperature
5.2 LIFE EXPECTANCY OF FAN
40,000 hours at 40℃
6. AGENCY APPROVALS
UL 60950-1, 2
nd
Edition
TUV ( EN60950-1: 2006+A11+A1+A12)
IEC 60950-1: 2005+A1
C-Tick AS/NS CISPR 22: 2006 (Class A) / CISPR 22: 2008 (Ed 6.0)
BSMI CNS14336-1, CNS13438
7. EMI /RFI
FCC part 15, Class A (Verification) IC ICES-003
EN55022 : 2006+A1: 2007 (Class A)
EN55024 : 1998+A1: 2001+A2: 2003
EN61000-3-2: 2006
EN61000-3-2: 2008
IEC61000-4-2, -3, -4, -5, -6, -8, -11
8. INSTRUCTIONS
The set still works properly even if either unit is removed. The removed unit can’t
be used in other machinery nor for other purpose. When one unit breaks down,
it’s LED will blink, buzzer will sound. Push the Reset button and buzzer will stop.
REDUNDANCY Offer redundant function for power system and mutually backs
up the outputs. A zero transfer time when backup takes place.
④
HOT-SWAP
The power system provides a Hot-Swap function. This means
when either one of the redundant power supplies fails or reaks
down, you can easily replace failed unit without any
interference to the system.
A warning buzzer sounds when any one of the power supplies
fails. The warning buzzer is reset table from reset switch either
the one in front control panel or the one on the rear side.
BUZZER
LED’S
The warning LED’S can be found either on the rear side or the
control panel of the power system. Tells if one of the two
power supplies has failed, by LED blinking.
HOT-PLUGGABLE The power system provides a Hot-Pluggable function
This method allows the power units in the Disk Array/
File Server to be removed or inserted very easily without
9. HOT-SWAP PROCEDURES
Please refer to the followings when either one power supply unit is fount defective.
A) Locate
the defective power supply by examining the individual LED on the
power unit or the LED on the front control panel if LED is Blinking.
B) Unlock & Remove
the defective power supply unit.
C)
Replace a new GOOD power supply unit, Insert the power supply into the
power system chassis in position & it will auto Lock-up.
D)
Turn on the new power supply unit.
E)
Check the module LED which indicate the power and LED of total power
system status, Both LED shall Have steady life.
10. DIMENSION
TC-XXXR2UH
L 280 x W170 x H 42 mm
⑤