EEWORLDEEWORLDEEWORLD

Part Number

Search

2200HAH40IPA2JB

Description
Strain Guage Sensor, Absolute, 0Psi Min, 4000Psi Max, 0.15%, 1-5V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200HAH40IPA2JB Overview

Strain Guage Sensor, Absolute, 0Psi Min, 4000Psi Max, 0.15%, 1-5V, Cylindrical

2200HAH40IPA2JB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Maximum accuracy(%)0.15%
shellSTAINLESS STEEL
Nominal offset1V
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range1-5V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type9/16 MALE
Maximum pressure range4000 Psi
Minimum pressure range
Pressure sensing modeABSOLUTE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typeDIN 9.4MM W/MATE
Base Number Matches1
Please give the picture a scientific name, I am confused
I have read a lot of information and summarized something, but I don't know what to call it specifically. I temporarily named it CC2530 key flow chart. I would like to ask you to give me a scientific ...
flying510 RF/Wirelessly
Remote Video Monitoring System Based on ARM-Linux and CDMA
Introduction CDMA (Code Division Multiple Access) wireless network has the characteristics of wide coverage, high efficiency and low cost. The data transmission rate of CDMA network can reach 200kb/s....
maker MCU
Does the common anode digital tube transistor driver need current limiting?
As shown in the following figure, it is a figure given by someone else. I feel that it is not appropriate. The 4 terminals on the top and the 8 terminals on the bottom are connected to the microcontro...
liyancao001 Integrated technical exchanges
Introduction to 7 common switching regulated power supplies
[Transfer] [font=宋体, SimSun]Among the loads, the voltage stabilizer plays a more important role. The voltage stabilizer can provide stable AC and DC power to the load. For different circuits, the swit...
木犯001号 Power technology
Help! Programming problem of phase difference meter based on mega16~~~~~~~~~~~~~~~~~
The peripheral connections of mega16 are as follows: the phase difference pulse signal is input from the PD6 port, and the phase difference relationship judgment signal is input from the PD7 port (the...
ttdiablo Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2079  916  357  1565  1934  42  19  8  32  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号