COLD START 30A(twidth=520 s measured at 50% Ipeak) at 115VAC
μ
COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC
μ
MAX. NO. of PSUs on 16A
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
CIRCUIT BREAKER
LEAKAGE CURRENT
OVER CURRENT
PROTECTION
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
<0.125mA / 120VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
15 ~ 17V
17.5 ~ 21V 23 ~ 27V
28 ~ 34V
34 ~ 40V
41 ~ 46V
46 ~ 54V
54 ~ 60V
59 ~ 66V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-40 ~ +70
℃
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
±
0.03%/
℃
(0 ~ 50
℃
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750 listed, CSA C22.2 No. 250.13-12; IP67(for power body) approved
I/P-O/P:3.75KVAC
Compliance to FCC Part15
294.3K hrs min.
191*63*37.5mm
1.15Kg; 12pcs/13Kg/0.89CUFT
MIL-HDBK-217F (25
℃
)
<0.25mA / 240VAC
ENVIRONMENT STORAGE TEMP., HUMIDITY
-40 ~ +80
℃
, 10 ~ 95% RH
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25
℃
/ 70% RH
EMC EMISSION
MTBF
OTHERS DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel
capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:OWA-120U-SPEC 2017-08-04
120W Single Output Moistureproof Adaptor
Block Diagram
O WA - 1 2 0 U
series
PFC fosc : 50~120KHz
PWM fosc : 60~130KHz
RECTIFIERS
&
FILTER
O.L.P.
O.T.P.
O.L.P.
PWM & PFC
CONTROL
DETECTION
CIRCUIT
O.V.P.
I/P
EMI FILTER
&
RECTIFIERS
PFC
CIRCUIT
POWER
SWITCHING
+V
-V
Derating Curve
Static Characteristics
100
100
90
80
230VAC
Input only
12V,15V only
80
70
60
LOAD (%)
LOAD (%)
-25
0
15
30
40 45 50
60
70 (HORIZONTAL)
50
40
60
50
40
20
-40
90
100
125
135
145
155 165
175
180
200
230
264
AMBIENT TEMPERATURE (
℃
)
INPUT VOLTAGE (V) 60Hz
Power Factor Characteristic
Constant Current Mode
1 .0 0
0 .9 5
0 .9 0
0 .8 5
0 .8 0
0 .7 5
0 .7 0
0 .6 5
0 .6 0
0 .5 5
0 .5 0
0 .4 5
0 .4 0
0 .3 5
0 .3 0
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
(120W)
LOAD
PF
230V
115V
File Name:OWA-120U-SPEC 2017-08-04
120W Single Output Moistureproof Adaptor
EFFICIENCY vs LOAD (48V Model)
O WA - 1 2 0 U
series
OWA-120U series possess superior working efficiency that up to 90.5% can be reached in field applications.
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
EFFICIENCY (%)
230V
115V
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method, "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV)" or "constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
100
(A) Constant
Voltage area
(B)
Constant
Current area
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.
60
(min.)
(C)
Hiccup
Protection
50
100
Io (%)
Vo(%)
Typical LED power supply I-V curve
File Name:OWA-120U-SPEC 2017-08-04
120W Single Output Moistureproof Adaptor
Mechanical Specification
O WA - 1 2 0 U
Case No. PWM-120
series
Unit:mm
1500
±
20
500
±
10
191
5
300
±
20
5
ψ
4.
T case
tc
63
5
95.5
50
±
3
23
14
SVT 18AWG
×
2C
31.5
5
2-
UL2464 18AWG
×
4C
5
tc
: Max. Case Temperature
Input Plug Ty
pe
All models : NEMA 1-15p male plug
3
Output Plug Assignment
All models : power DIN 4 pins with lock type,
KYCON KPPX-4P, or equivalent
PIN NO. OUTPUT
2
1
3
4
1,4
2,3
+V
-V
Recommend Mounting Direction
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
To facilitate your reference, I have compiled all the posts that you have made in Launchpad University according to the outline here and will continue to update them.Introduction to LaunchPad Developm...
Let's discuss the technical issues of Symbian smartphone operating system. Brothers and sisters who are engaged in Symbian smartphone R&D or related telecommunications fields, I have been engaged in t...
In serial communication, the program on the TI routine enters the sleep state. Once the data is received, the execution command is interrupted. However, during the program running, the received data i...
Digital temperature controller. And a heating plate.
Is it better to connect the heating plate directly to the output terminal of the temperature controller? Or should I add an intermediate relay to c...
Solomon's GPRS MODEM device uses AT command: AT+CMGS = phone numberInformation content
The sending failed. Is it because the AT command of this device is different from other devices? Please help me, ...
In early 2002, I started to write a working program for an IC card prepaid electricity meter. The meter used Philips' 8-bit 51-expanded single-chip microcomputer
87LPC764
, and wa...[Details]
A single-chip microcomputer is also called a single-chip microcontroller. It is not a chip that completes a certain logical function, but a computer system integrated into one chip. In general, a c...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
In this article, the high-performance DSP developed by TI can be used as an effective confidentiality method if it is applied to PC encryption cards.
As an effective network security solution,...[Details]
In public places such as schools, government agencies, factories and mines, as well as public corridors in residential areas, the phenomenon of long-burning lights is very common, which causes a h...[Details]
My colleague and I spent the day chatting in the hotel bar. We had met with several customers. We were both wondering how come these engineers we were meeting knew almost nothing about analog techn...[Details]
Contact resistance
is the resistance to current flow through a closed pair of contacts. This type of measurement is performed on devices such as connectors,
relays
, and switches. The...[Details]
1 Introduction to HART Protocol
HART (Highway Addressable Remote Transducer), an open communication protocol for addressable remote sensor high-speed channels, was launched by Rosemen in the U...[Details]
In the analysis of electronic circuits, static analysis (also known as DC analysis) is the basis of circuit analysis. However, it is well known that electronic components are nonlinear, so the anal...[Details]
RS-422 and RS-485 are both serial data interface standards, which were developed and published by the Electronic Industries Association (EIA). RS-422 defines a balanced communication interface with a ...[Details]
In recent years, with the rapid development of the information industry, dot matrix LED display screens have been widely used in various advertising and information display systems such as the fina...[Details]
Continuity test
A variety of devices need to be checked for continuity, including cable assemblies, printed circuit boards, and connectors to ensure that these components have the expected contin...[Details]
Today, the value of electronic components in cars accounts for 15-20% of the total vehicle. In the future, this proportion may be as high as 30-40% as more safety electronics, fuel consumption and ...[Details]
Describe how to meet the challenges of complexity with a modern wiring design toolset. Option codes and expressions can simulate the variables of an automotive project. A full-featured tool suite c...[Details]
Since the late 1990s, with the demand for higher system efficiency and lower power consumption, the technological update of telecommunications and data communication equipment has promoted the deve...[Details]