NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Current
Inrush current <2ms
External fuse
Input dissipation
Leakage current
Conditions
115VAC
230VAC
115VAC
230VAC
Recommended slow blow type
No Load
CY(Input to Output) 1nF/400VAC
Typical
5
10
1
Maximum
200
100
Units
mA
mA
A
A
A
W
µA
0.5
250
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise
Over current protection
Short circuit protection
Short circuit restart
Over Voltage protection
Hold up time
Conditions
Full load, 3.3V output
Full load, others
Full load
10% - 100% load
20MHz Bandwidth
Auto-recovery
Typical
Maximum
±3
±2
±0.5
±1.5
150
Units
%
%
%
mV p-p
% of I out
115VAC
230VAC
≥110
Continuous
Auto-recovery
Zener diode clamp
20
80
ms
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec, 5mA leakage current
Typical
>1000
Rated
3000
Units
VAC
MΩ
www.aimtec.com
F 052e R0
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
O
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Weight
Dimensions
(L x W x H)
MTBF
Series AMEOF5-JZ
5 Watt | AC-DC Converter
Conditions
See derating curve
Typical
100
-25 to +85
-40 to +105
±0.02
Free air convection
Maximum
Units
KHz
°
C
°
C
% /
°
C
85
7
1.65 x 0.54 x 0.79 inches
42.00 x 13.65 x 20.00 mm
o
>300,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C)
% RH
g
Safety Specifications
Parameters
IEC/EN/UL60950-1 pending approval
EN 55022, Class A & B, with external filter circuits, as referenced
IEC 61000-4-2, Contact ±4KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A, with Class A external filter, as referenced
IEC 61000-4-4, ±2KV/±4KV, Criteria B, with Class A/B external filter referenced
IEC 61000-4-5, ±1KV/±2KV, Criteria B, with Class A/B external filter referenced
IEC 61000-4-6, 3Vrms, Criteria A, with Class B external filter, as referenced
IEC 61000-4-8, 10A/m, Criteria A
IEC 61000-4-11, 0-70%, Criteria B
Standards
Pin Out Specifications*
Pin
1
3
5
7
12
14
Single
AC N
AC L
+V sc
-V sc
-V Output
+V Output
1
10.00
(0.39)
1.30
(0.05)
42.00
(1.65)
Dimensions
Bottom View
Front View
20.00
(0.79)
13.65
(0.54)
0.50
(0.02)
* Add capacitor between pin 5 & 7.
Application circuit below.
3
5
7
12
14
1.50
(0.06)
4.40
(0.17)
33.02
(1.30)
5.08
(0.20)
L models
Front view
Note:
Unit: mm (inch)
Pin diameter tolerance: ±0.10 (±0.004)
Case tolerance: ±0.50 (±0.02)
Right view
6.00
(0.24)
5.08
(0.20)
33.02
(1.30)
0.80
(0.03)
www.aimtec.com
F 052e R0
Tel: +1 514 620 2722
2 of 3
4.40
(0.17)
1.60
(0.06)
13.65
(0.54)
0.40
(0.02)
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
O
Derating*
Free Air Convection
100
Series AMEOF5-JZ
5 Watt | AC-DC Converter
Free Air Convection at 25°C
100
Output Power (%)
80
60
40
20
0
- 25
Safe Operating Area
Input 110-240VAC or
135-320VDC
80
60
40
20
Safe Operating Area
-20
0
20
40
55
60
80
85
0
100
Ambient Temperature
º C
*Power derating: for 85-110VAC and 240-264VAC input supply
85
110
(70) (100)
240
(340)
Input Voltage VAC (VDC)
264
(400)
Recommended EMC class A external circuit:
FUSE
1A/250V
AC L
CX1
0.1µF/
300V
C1
10µF/
400V
+
NTC
R
12Ω
3
5
AC
7
1
12
CY1
1nF/400VAC
DC
+
C2
Single Output
14
TVS
C3
0.1µF/50V
‐ Vout
+Vout
MOV
S14K350
AC N
Recommended EMC class B external circuit:
FUSE
1A/250V
AC L
CX
0.1µF/
300VAC
CY2
1nF/
400VAC
CY3
1nF/
400VAC
LCM
3.5mH
LDM
0.33mH
Single Output
NTC
3
+
C1
10µF/
400V
12
TVS
+Vout
5
AC
7
1
10
CY1
1nF/400VAC
DC
+
C2
MOV
S14K350
AC N
GND
C3
0.1µF/50V
‐ Vout
Model
3.3 & 5 Vout
9 Vout
12 & 15 Vout
24 Vout
C2
220 µF / 35V
150 µF / 35V
TVS
7V
12V
20V
30V
Note: For Safety compliance we recommend minimum PCB trace distance of
3mm, primary to secondary circuit minimum distance between PCB traces of
6.4mm.
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4
. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this
datasheet
.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.