PCST24-Z3-2500-U8-PMU Overview

Rod-Style Design with Analog Output

POSICHRON
®
PCST24
Rod-Style Design with Analog Output
POSICHRON
®
rod-style position sensor
For hydraulic cylinders, fluid level measurement
Protection class up to IP67/IP69K
Measurement range ... 100 to 0 ... 5750 mm
0
Absolute position measurement
Contactless
Replaceable electronics without leakage
Analog output
Specifications
Output
Resolution
Sampling rate
Linearity
Repeatability
Housing material
Mounting
Working pressure of sensor rod
Protection class
Shock
Vibration
Connection
EMC, temperature
Voltage
Current
Refer to output specification
Up to 1 kHz, depending on the measurement range
Ranges >500 mm: L10 = ±0.10 % f.s.
L02 = ±0.02 % f.s.
Ranges ≤500 mm: L10 = ±0.5 mm
L02MM = ±0.2 mm
±3 µm
Sensor rod: stainless steel 1.4404, head: AlMgSi
Thread M18x1,5 / thread ¾ inch
400 bar, other values on request
IP67 (optional IP67/IP69K; connector version: with
mating connector only)
EN 60068-2-27:2010, 50 g 11 ms, 100 shocks
EN 60068-2-6:2008, 20 g 10 Hz-2 kHz, 10 cycles
8 pin socket M12, cable 2 m
Refer to output specification
Order code PCST24
Model name
1 channel
Mounting
PCST24
= Thread M18x1,5
M18
Z3/4
= Thread ¾ "-16 UNF
Measurement range (in mm)
100 ... 5750 (in 10 mm increments)
other lengths upon request
Output
U1
U1/H
U2
U2/U; U2/H
U8
U8/U; U8/H
I1
I1/U; I1/H
= 0 ... 10 V signal conditioner
= U1 with Alarm_HOLD (see page 16)
= 0.5 ... 10 V signal conditioner
= U2 with Alarm_LOW; U2 with Alarm_HOLD (see page 16)
= 0.5 ... 4.5 V signal conditioner
= U8 with Alarm_LOW; U8 with Alarm_HOLD (see page 16)
= 4 ... 20 mA signal conditioner (3 wire)
= I1 with Alarm_LOW; I1 with Alarm_HOLD (see page 16)
Function and characteristics output
P1A
= Position Magnet 1, increasing
P1D
= Position Magnet 1, decreasing
PMU
= Start value, direction & end value adjustable by the customer
Linearity
L02 / L02MM / L10 (for definition see "Specifications" above)
Connection
M12
= Connector M12, 8 pin
= Cable, standard length 2 m, other lengths upon request
KAB2M
DB-PCST24-E-2013-11
www.asm-sensor.com
1/21
© ASM GmbH
info@asm-sensor.com

Recommended Resources

Relationship between differential input range and IN-, IN+ range
This is an AD data sheet. Does it mean that the true differential input range can be: -Vref to + Vref and 0 to +Vref? Does the differential input range refer to the difference between the two pins? Wh...
萤火 ADI Reference Circuit
Electronic Design Tips
Basic information on electronic design competition! Absolutely informative!...
Wen_Jin Electronics Design Contest
[First come first served double gift] Become the first 100 pioneers to experience the Fluke New Era 640 Infrared Thermal Imager
[url=https://www.eeworld.com.cn/huodong/FLUKE_201905/index.html][size=5]Event details: >>[/size][/url] Participate in the event and submit the form. Not only can you experience FLUKE's new 640 infrare...
EEWORLD社区 Test/Measurement
TM4C123G uses ADC and GPIO to cause FaultISR
[align=left][color=#000]I encountered a problem when I was just starting to learn M4. I added the use of the ADC module to the TI official routine timers, and used a display screen driven by a common ...
nemo1991 Microcontroller MCU
Easy Power Supply Experience
TI's method of combining learning with playing is very good. At first, I thought the questions would be difficult, but I didn't expect that they were so simple after playing. The title is just as it s...
philipjunn Analogue and Mixed Signal
Why is my int select(int nfds, fd_set Far* readfds, fd_set Far* writefds, fd_s
fd_set fdread; FD_ZERO(&fdread); u_long i=1; FD_SET(m_recv.m_hSocket,&fdread); ioctlsocket(m_recv,FIONBIO,&i); select(0,&fdread,NULL,NULL,0); Why doesn't my function return immediately? Shouldn't it r...
emaster Embedded System

Popular Articles

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2428  192  1044  152  16  49  4  22  1  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号