PCST25-Z3-1500-U2-P1A

Description
Rod-Style Design with Analog Output
File Size2MB,19 Pages
ManufacturerASM
Download Datasheet View All

PCST25-Z3-1500-U2-P1A Overview

Rod-Style Design with Analog Output

POSICHRON
®
PCST25
Rod-Style Design with Analog Output
POSICHRON
®
rod-style position sensor
For hydraulic cylinders, fluid level measurement
Protection class up to IP67/IP69K
Measurement range ... 100 to 0 ... 5750 mm
0
Absolute position measurement
Contactless
Analog output
Specifications
Output
Resolution
Sampling rate
Linearity
Repeatability
Housing material
Mounting
Operating pressure
Protection class
Shock
Vibration
Connection
EMC, temperature
Voltage
Current
Refer to output specification
Up to 1 kHz, depending on the measurement range
Ranges >500 mm: L10 = ±0.10 % f.s.
L02 = ±0.02 % f.s.
Ranges ≤500 mm: L10 = ±0.5 mm
L02MM = ±0.2 mm
±3 µm
Sensor rod: stainless steel 1.4404, head: AlMgSi
Thread M18x1,5 / thread ¾ inch / plug-in mounting
400 bar, other values on request
IP67 (optional IP67/IP69K)
EN 60068-2-27:2010, 50 g 11 ms, 100 shocks
EN 60068-2-6:2008, 20 g 10 Hz-2 kHz, 10 cycles
Cable 2 m
Refer to output specification
Order code PCST25
Model name
1 channel
Mounting
PCST25
M18
= Thread M18 x 1,5
Z3/4
= Thread ¾"-16UNF
SV
= Plug-in version
Measurement range (in mm)
100 ... 5750 (in 10 mm increments)
other lengths upon request
Output
= 0 ... 10 V signal conditioner
U1
U1/H
= U1 with Alarm_HOLD (see page 14)
U2
= 0.5 ... 10 V signal conditioner
U2/U; U2/H = U2 with Alarm_LOW; U2 with Alarm_HOLD (see page 14)
U8
= 0.5 ... 4.5 V signal conditioner
U8/U; U8/H = U8 with Alarm_LOW; U8 with Alarm_HOLD (see page 14)
I1
= 4 ... 20 mA signal conditioner (3 wire)
I1/U; I1/H
= I1 with Alarm_LOW; I1 with Alarm_HOLD (see page 14)
Function and characteristics output
P1A
= Position Magnet 1, increasing
P1D
= Position Magnet 1, decreasing
PMU
= Start value, direction & end value adjustable by the customer
Linearity
L02 / L02MM / L10 (for definition see "Specifications" above)
Connection
KAB2M
= Cable, standard length 2 m, other lengths upon request
DB-PCST25-E-2013-11
www.asm-sensor.com
1/19
© ASM GmbH
info@asm-sensor.com
Has anyone used the PWM function of PIC16F1827?
I'm working on a device and I can't get the PWM function to work. Can anyone who has done this before help me? Thanks a lot!...
and01 Microchip MCU
Image processing filtering algorithm
1. Learning experience:When I was learning the basic principles of filtering algorithms, I didn’t quite understand how the algorithms were implemented because I had just started. However, after learni...
火辣西米秀 Analogue and Mixed Signal
【Uncle T's Library】CMOS VLSI Design A Circuits and Systems Persp...
[p=24, null, left][color=rgb(86, 86, 86)][backcolor=rgb(237, 235, 235)][font=微软雅黑][size=14px][url=https://download.eeworld.com.cn/detail/tyw/561233][color=#0066cc]《CMOS VLSI Design A Circuits and Syst...
tyw Download Centre
DB9 Application Detailed Explanation
Serial communication is often used and some can be applied in practice...
backhuli 51mcu
Can someone please tell me how to measure the temperature? Thank you.
Could someone explain how to use this to measure temperature? Thanks...
akii0401 Integrated technical exchanges
wince s3c2440 camera problem? ?
My camera has a resolution of 720*288, and is displayed on a 7-inch TFT (800*480). During debugging, I found that the images on the left and right ends of the horizontal direction are missing and cann...
mfhsu Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1884  1404  1770  618  947  38  29  36  13  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号