EEWORLDEEWORLDEEWORLD

Part Number

Search

28-002.25-173PTL

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size243KB,2 Pages
ManufacturerAries Electronics
Environmental Compliance
Download Datasheet Parametric View All

28-002.25-173PTL Overview

Interconnection Device, ROHS COMPLIANT

28-002.25-173PTL Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompli
ECCN codeEAR99
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
Series 171 thru 173
Flat Pin Staked Flex Jumpers
FEATURES:
• Aries Flat Pin Staked Flex Jumpers combine thin, flexible, solid Copper
conductors embedded between layers of tough, flexible, flame-
retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See DataSheet
11019
for 90° Pin Staked Flex Jumpers.
• For RoHS applications for Lead-Free Soldering use HT Cable.
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant
Polyester (Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide
(Kapton) insulation with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equiva-
lent to that of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper
Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min
Nickel per SAE-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over
50μ” [1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps.
• Cable voltage rating=300 Volts.
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp.).
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp.).
• Operating temperature=-67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square, .150 [3.81]
long minimum.
MOUNTING CONSIDERATIONS:
•Suggested PCB hole size=.032 ± .002 [.81 ± .05] dia.
Note: Aries specializes in custom design and production. In addition to the
standard products shown on this page, special materials, platings, sizes, and
configurations can be furnished, depending on quantities. Aries reserves the
right to change product specifications without notice.
ORDERING INFORMATION
XX-XXXXX-17XXXXXX
Optional Suffix:
HT = High
temp. cable
insulation
Optional Suffix:
TL = Tin/Lead
Plating
Optional Suffix:
P= polarization
stripe along one
edge of cable**
No. of conductors
(4 thru 40)
Kapton is a registered trademark of DuPont
Cable length: “L” in inches:
Min. Cable Length = 2.00” (-002-)
2” = -002-
2.5” = -002.5-
2.25” = -002.25-
2.125” = -002.125-
Jumper series:
171: male Tin both ends
172: male Tin/female Tin
173: female Tin both ends
CABLE DETAIL
MALE CONTACT DETAIL
** Aries reserves the right to
ship with or without a polariza-
tion stripe unless otherwise
specified by the customer
http://www.arieselec.com • info@arieselec.com
Bristol, PA USA
TEL: (215) 781-9956
FAX: (215) 781-9845
abc
11005
REV. J
Page 1 of 2
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
Has anyone done this picture of OPA454 (figure76)? ? My result is not coming out? ?
Has anyone done this picture? ? My result is not coming out? ?...
lyf870615 Analog electronics
Although it is very simple, we still have to ask: ADC sampling control register sampling channel settings
Write Read_Adc in the ADC driver, set the sampling channel, pADCIOreg->rADCCON = (1rADCCON = (1rADCCON |= 0rADCCON |= 0x1; // start adc while(pADCIOreg->rADCCON & 0x1); //check if Enable_start is low ...
jie3303 Embedded System
What is the principle of the water level sensor of the solar water heater controller
I measured the resistance of the sensor. At different water levels, the resistance value will slowly rise, and finally it will be 60k or close to it. What is the principle behind this, or is the measu...
djf876 Energy Infrastructure?
How to draw the graph of the complex number solution of X^2+1=0 in the coordinate system? Can anyone help me? Thank you.
How to draw the graph of the complex number solution of X^2+1=0 in the coordinate system? Can anyone help me? Thank you. I don't understand what the picture below means. Can you help explain it to me?...
深圳小花 MCU
Familiar with DSP and MCU development, please enter
A well-known enterprise in Jiangsu is recruiting embedded control development engineers.Requires relevant experience in electrical product development and familiarity with DSP\MCU developmentIf you ar...
lena Recruitment
USB wireless network card driver displays yellow exclamation mark
Initially the installation was normal, but after repeatedly unplugging and plugging the device, the driver displayed a yellow exclamation mark. What could be the cause of this?...
wzy19970701 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1385  639  577  2632  1504  28  13  12  53  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号