EEWORLDEEWORLDEEWORLD

Part Number

Search

U5392-020005-100PS

Description
Peizoresistive Sensor, 0Psi Min, 100Psi Max, 0.1%, 0.5-4.5V, Cylindrical
CategoryThe sensor   
File Size319KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

U5392-020005-100PS Overview

Peizoresistive Sensor, 0Psi Min, 100Psi Max, 0.1%, 0.5-4.5V, Cylindrical

U5392-020005-100PS Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145066227313
Reach Compliance Codeunknown
Maximum accuracy(%)0.1%
Other featuresPort Height = 15.24 MM
body height64.9 mm
Body length or diameter24 mm
Maximum working current5 mA
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0.5-4.5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port type1/4-18 NPT
Maximum pressure range100 Psi
Minimum pressure range
Pressure sensing modeSEALED
Sensor/temperature sensor typePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage30 V
Minimum supply voltage5 V
Termination typeCABLE
U5300
Industrial Pressure Transducer
SPECIFICATIONS
Superior Accuracy and Total Error Band
Instrument Grade and Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Absolute, Compound
Expedite Configurations Available (10 Days)
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.1% Accuracy
±0.5% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The instrument grade U5300
pressure transducers from the UltraStable line
of MEAS, with their modular design, offer maximum flexibility for different
configurations. This latest series features superior accuracy and total error
band for demanding commercial and heavy industrial applications. This
series is suitable for measurement of liquid or gas pressure, even for difficult
media such as contaminated water, steam, and mildly corrosive fluids.
The wetted material is made of 316L stainless steel and the transducer’s
durability is excellent with no organics exposed to the pressure media. The
U5300 is weatherproof and exceeds the latest heavy industrial CE
requirements including surge protection. The circuit is protected from reverse
wiring at input and short circuit at output.
This product is geared to the OEM customer for low to mid volumes. MEAS
stands ready to provide a custom design of the U5300 where the volume and
application warrants. Additional configurations not listed are either available
or possible. Please inquire for further information.
APPLICATIONS
Military/Aerospace Test Stands
Automotive Test Stands
Calibration Equipment
High Accuracy Applications
Stationary Motor Fuel Control
High End Industrial Machinery
SENSOR SOLUTIONS
///U5300
10/2021
Page 1
Ask a simple question
How to add annotations to the .bdf file of Quartus II? Just like in the circuit diagram, the same lines are not connected but marked with the same name to indicate that they are connected....
xiha FPGA/CPLD
I would like to ask experts to help me understand the differences between multi-threaded memory management under EVC and under VC, and what should I pay attention to?
I would like to ask experts to help me understand the differences between multi-threaded memory management under EVC and VC. What should I pay attention to? Recently, due to project requirements, I wa...
szkyd Embedded System
During the development of ce5.0 program by evc4.0, the program exited.
During the process of developing ce5.0 program with evc4.0, the program exited. Tip: exited with code 3(0x03);...
zhangcf Embedded System
Differences between H.264 products
Need help for work! Can any professional tell me which manufacturers produce the H.264 video transmission products commonly used in video conferencing systems, and what are the similarities and differ...
aaixinjue Embedded System
In-vehicle OBD Bluetooth products based on SensorTag
[i=s]This post was last edited by desk1983 on 2014-3-5 11:01[/i] [media=x,500,375]http://v.youku.com/v_show/id_XNjgwNjUzNjky.html[/media]...
desk1983 Wireless Connectivity
How to add your own input method in WINCE? If you have an input method DLL, how to add a registry key to make it be called?
How to add your own input method in WINCE? If you have an input method DLL, how to add a registry key to make it be called?...
fengyon168 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 231  782  994  1901  79  5  16  21  39  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号