Parallel - Fundamental Quartz Crystal, 20MHz Nom, SMD, 4 PIN
ABM8-20.000MHZ-18-7W-T3 Parametric
Parameter Name
Attribute value
Is it Rohs certified?
conform to
Objectid
145206924224
package instruction
SMD, 4 PIN
Reach Compliance Code
unknown
Ageing
2 PPM/FIRST YEAR
Crystal/Resonator Type
PARALLEL - FUNDAMENTAL
Drive level
10 µW
frequency stability
0.0025%
frequency tolerance
15 ppm
JESD-609 code
e4
load capacitance
18 pF
Installation features
SURFACE MOUNT
Nominal operating frequency
20 MHz
Maximum operating temperature
60 °C
Minimum operating temperature
-10 °C
physical size
3.2mm X 2.5mm X 0.8mm
Series resistance
50 Ω
surface mount
YES
Terminal surface
Nickel/Gold (Ni/Au)
ABM8-20.000MHZ-18-7W-T3 Preview
CERAMIC SMD CRYSTAL
ABM8
Moisture Sensitivity Level (MSL) – This product is Hermetically Sealed and not Moisture
Sensitive - MSL = N/A: Not Applicable
Pb
RoHS
Compliant
3.2 x 2.5 x 0.8mm
FEATURES:
• Seam sealed package assures high reliability
• Tight tolerance and stability available
• Suitable for RoHS reflow
APPLICATIONS:
• High density applications
• Modems, communication and test equipment
• PMCIA, Wireless applications
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the Operating
Temperature ( ref. to +25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging
Insulation Resistance
TABLE 1- Standard ESR
Frequency (MHz)
10.000 -11.999 (Fund)
12.000 -15.999 (Fund)
16.000 -19.999 (Fund)
20.000 - 29.999 (Fund)
-2
500
ESR( )
max
200
120
70
50
Minimum
10.000
Typical
Maximum
125.000*
Units
MHz
Notes
Contact Abracon for
available F<10MHz
10MHz - 54MHz
64MHz - 125MHz
Please contact Abracon for
available frequencies
Fundamental
3rd Overtone
(Standard Frequencies: 64, 66, 66.6666, 75,
80, 98.304, 100, 125MHz)
-10
+60
-55
+125
-50
+50
-50
See table 1 below
3.0
18.0
10
100
+2
+50
ºC
ºC
ppm
ppm
pF
pF
µW
ppm
M
(see options if other than STD)
Standard
Standard
Standard
(see options if other than STD)
(see options if other than STD)
Standard
(See options if
other than STD)
@25°C±3°C
First year
@ 100Vdc ± 15V
ESR( )
max
40
35
120
80
Frequency (MHz)
30.000 - 39.999 (Fund)
40.000 - 54.000 (Fund)
64.000 - 80.000 (3rd OT)
98.304 - 125.000 (3rd OT)
OPTIONS AND PART IDENTIFICATION: (Left blank if standard)
ABM8
Height (mm)
Blank: 0.80 max
1: 0.65±0.05
2: 0.60±0.10
Frequency in MHz
Please specify the
frequency in MHz.
e.g. 16.000MHz
Load Capacitance (pF)
Please specify CL (min
6pF) in pF or S for series
Custom ESR if
other than standard
R
: Specify a value in
(e.g.: R40)
Operating Temp.
E
Blank: -10°C ~ +60°C
E: 0°C ~ +70°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J**: -40°C ~ +105°C
K**: -40°C ~ +125°C
** Frequency stability ±
50ppm and ± 100 ppm
-
MHz -
-
-
-
Packaging
Blank: Bulk
T: 1kpcs / reel
T2: 250pcs / reel
T3: 3kpcs / reel
Freq. Stability
Blank: ± 50 ppm
U: ± 10 ppm(*)
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Q: ± 100 ppm
(*) Option E, B, and
-10°C to +60°C only.
Freq. Tolerance
Blank: ± 50 ppm
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
LLC
5101 Hidden Creek Ln Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sales, please visit:
www.abracon.com
ABRACON IS
REVISED: 07-1-20
ISO9001-2015
CERTIFIED
CERAMIC SMD CRYSTAL
ABM8
OUTLINE DRAWING:
Pb
RoHS
Compliant
3.2 x 2.5 x 0.8mm
Note:
Due to material availability, the chamfer could be located
on pin #1, 3, or 4. Be advised that the chamfer location has
no impact on the electrical performance of the device.
Table 2
Height (mm)
ABM8
0.80 max
ABM81
0.65+/-0.05
ABM82
0.60+/-0.10
Dimensions: mm
TAPE & REEL:
Option "-T"
: Tape and reel (1,000pcs/reel) : ABM8, ABM82
Tape and reel (3,000pcs/reel) : ABM81
Option "-T2" : Tape and reel (250pcspcs/reel) : ABM8
Option "-T3" : Tape and reel (3,000pcs/reel) : ABM8, ABM82 only
REFLOW PROFILE:
Zone
1
2
3
Dimensions: mm
Description
Temperature
Time
Preheat
Reflow
Peak heat
T
SMIN
~ T
SMAX
150°C ~ 180°C
T
L
230°C
T
P
260°C
±
5°C
60 ~ 120 sec.
30 ~ 40 sec.
10 sec. MAX
ATTENTION:
Abracon LLC’s products are COTS – Commercial-O -The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applica-
tions. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependent Medical applications or any application requiring high reliability
where component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment,
written consent and authorization from Abracon LLC is required. Please contact Abracon LLC for more information.
Has anyone used the OK2440 development board? I just started learning and encountered a very strange problem. When using DNW's USB to download the kernel file nk.bin or nk.nb0, it keeps prompting chec...
If the 430 microcontroller does not have a watchdog, will it often crash when working in a harsh environment? I don't have an external watchdog, and now I want to use an internal watchdog, but after a...
If you want PB4.2 you need WINCE, build the build 1 single key, the build code If you want to install WINCE420 with a build.err file, you can install it: Microsoft (R) Program Maintenance Utility Vers...
BOOL I2C_IOControl( DWORD context, DWORD code, BYTE *pInBuffer, DWORD inSize, BYTE *pOutBuffer, DWORD outSize, DWORD *pOutSize ) defines a BYTE *str; then gives it space and value, but I don't know ho...
This program is written to simulate the serial port hardware mechanism. When used, a timed interrupt can be set with a time interval of 1/4 baud rate. The receiving function is called once for ea...[Details]
In early 2002, I started to write a working program for an IC card prepaid electricity meter. The meter used Philips' 8-bit 51-expanded single-chip microcomputer
87LPC764
, and wa...[Details]
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
1 Introduction
With the acceleration of the pace of urban modernization, society has higher requirements for urban road lighting and urban lighting projects. The state has clearly required tha...[Details]
DSP (digital signal processor) is used more and more frequently in today's engineering applications. There are three main reasons for this: first, it has powerful computing power and is capable of ...[Details]
This paper establishes a fuel cell engine test platform based on the NI integrated hardware and software environment. This platform can realize the test and control of fuel cell engines and their a...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
This week, Microsoft held its 2012 Microsoft Worldwide Partner Conference (WPC) in Toronto, Canada. At the conference, Microsoft showed its new products and services to partners around the world. A...[Details]
Abstract: With the development and construction of BeiDou II system, China will shift from the situation dominated by GPS to the situation dominated by BeiDou II global navigation system independen...[Details]
Today, with energy becoming increasingly scarce, the utilization of natural energy has become the focus of people's attention. Among various natural energies, the endless solar energy is highly fav...[Details]
0 Introduction
High-precision current source can provide high-precision current supply for precision instruments, and is suitable for automatic measurement tasks of various resistors in semico...[Details]
Introduction
Nowadays, people pay more and more attention to the security alarm system, and people have higher and higher requirements for the functions and performance of the alarm. This paper prop...[Details]
introduction
At present, measuring instruments are developing towards networking, and each individual embedded instrument will become a node on the Internet. This system realizes the network...[Details]